Cost-effectiveness of human leukocyte antigen matching in penetrating keratoplasty
Background: The matching of favorable human leukocyte antigen (HLA) combinations is rarely performed in penetrating keratoplasty procedures for primary prophylaxis of immune reactions. However, clinical studies suggest that the incidence of graft rejection decreases substantially when patients receive favorably matched grafts.
Objective: The aim of this study was to assess the cost-effectiveness of HLA matching for patients undergoing penetrating keratoplasty in everyday clinical practice.
Methods: In the absence of a randomized controlled clinical trial, we used administrative data from the Freiburg University Eye Hospital in Germany. Our study population consisted of all patients who underwent their first keratoplasty between 11/2003 and 01/2010 and for whom information on HLA histocompatibility was available. We used propensity score matching to estimate a causal effect of favorable HLA matching, parametric survival regression techniques to predict graft survival and expert opinion to model incremental cost for HLA matching. Because the availability of favorable HLA histocompatibility ultimately depends on the patients’ HLA phenotype, we modeled the incremental cost-effectiveness ratio (ICER) as a function of the probability that a patient will receive a favorably matched HLA, and used expert opinion to set a point estimate.
Results: We predicted that corneal grafts with favorable HLA matching were associated with improved rejection-free graft survival time (more than 1,000 days). We estimated the incremental cost of HLA matching at EUR 1,200 and the ICER at EUR 4.62 per additional day of graft survival.
Conclusions: The ICER of HLA matching is acceptable, given the high cost of alternative treatment and the shortage of corneal donors in Germany
Attitudes Concerning Postmortem Organ Donation : A Multicenter Survey in Various German Cohorts
BACKGROUND
The aim of this study was to characterize postmortem organ donation attitudes in various German cohorts.
MATERIAL AND METHODS
Employees of 2 German cities and 2 German university hospitals, employees of a German automobile enterprise, and members of a German Medical Society were administered a questionnaire about postmortem organ and tissue donation attitudes. Demographic data and general attitudes were questioned and focused on: I) willingness to donate organs, II) holding a donor card, and III) having discussed the topic with the family.
RESULTS
Of 5291 participants, 65.2% reported favoring postmortem organ donation. Missing negative experiences, the idea that donation is helpful, a non-medical professional environment, excellent general health, gender, agreement with the brain-death paradigm, and age significantly influenced the participants’ attitudes. Participants were more likely to possess donor cards and had discussed more often with family members if they agreed with the brain-death paradigm and considered donation to be helpful. Males and older participants were the most likely to neglect donor cards, and Catholics, Protestants, and participants with poor health were the least likely to donate organs. Interest in receiving more information was expressed by 38.1% and 50.6% of participants refusing donation of all or of specific organs, respectively, and suggested the internet (60.0%) and family doctors (35.0%) as preferred sources of information.
CONCLUSIONS
Public campaigns in Germany should focus on males and older people as regards donor cards, and females, younger, and religiously affiliated persons as regards the general willingness to donate organs postmortem
XEN®-63 Compared to XEN®-45 Gel Stents to Reduce Intraocular Pressure in Glaucoma
The XEN® gel stent reduces intraocular pressure (IOP) in glaucoma. XEN®-45 is widely used; the newer XEN®-63 has a larger lumen targeting potentially lower IOP outcomes. We retrospectively compared the first 15 XEN®-63 cases to 15 matched XEN®-45 controls. With a preoperative IOP of 18.1 ± 3.9 mmHg (mean ± SD) and a final IOP of 9.1 ± 2.0 mmHg, XEN®-63 implantation resulted in an IOP reduction of 44.6 ± 16.5%. Similarly, with a preoperative IOP of 18.3 ± 4.5 mmHg and a final IOP of 10.3 ± 2.1 mmHg, XEN®-45 implantation resulted in an IOP reduction of 40.1 ± 17.2%. The median follow-up period was 204 days (range 78–338 days) for the XEN®-63 group and 386 days (range 99–1688 days) for the XEN®-45 group. In total, 5/15 eyes of each group underwent open conjunctival bleb revision within the period of observation. Three eyes of the XEN®-63 group had secondary glaucoma surgery. One eye in the XEN®-63 group and three eyes in the XEN®-45 group required a restart of antiglaucomatous medication. In conclusion, both stents effectively lower IOP and medication. XEN®-63 achieved a slightly lower IOP over a short follow-up. Complication and revision rates were similar
XEN®-45 implantation for refractory uveitic glaucoma.
Purpose: To evaluate the efficacy of XEN®-45 gel stent ab interno implantation for medically uncontrolled uveitic glaucoma. Methods: Retrospective analysis of 25 eyes receiving XEN® gel stent for medically uncontrolled uveitic glaucoma from February 2019 to February 2023 with recording of intraocular pressure (IOP) values, ocular hypotensive medication, requirement for revision or secondary surgery and complications. Prerequisites for XEN® implantation were a clear cornea, an open iridocorneal angle and an unscarred, mobile conjunctiva at the implantation site. Minimum follow-up required for inclusion was 3 months. The primary outcome measure was IOP compared to baseline. Complete and qualified success were defined as final IOP of ≤ 18 mmHg without or with topical antiglaucomatous treatment, respectively. Failure was defined as IOP > 18 mmHg on two consecutive visits, IOP reduction < 20%, persisting complications from hypotony and open conjunctival bleb revision. Further glaucoma surgical intervention was defined as complete failure. Results: Mean preoperative IOP was 35.3 ± 10.9 mmHg on 2.9 ± 0.9 topical antiglaucomatous agents. 19 of 25 patients (76%) received additional oral acetazolamide. 19 eyes were pseudophakic, 5 eyes phakic and 1 aphakic. Early postoperatively, mean IOP reduced to 7.7 ± 3.0 mmHg (75.8% reduction). At final follow-up (mean 17.7 months) mean IOP was 12.0 ± 3.8 mmHg (62.5% reduction) on 0.2 ± 0.6 medications. Six eyes (24%) required bleb revision at mean 28 weeks and therefore were categorized as failure. One eye failed despite bleb revision and restart of topical ocular hypotensive medication. Three other eyes (12%) had IOP spikes with uveitis flare-ups. Transient hypotony complications occurred in 32%. At final follow-up, 18 eyes (72%) achieved complete success and one eye (4%) qualified success. Conclusion: The XEN® gel stent effectively reduced IOP in uncontrolled uveitic glaucoma, with 72% complete success. Bleb revision was required in 24%. IOP spikes occurred in 12% despite functioning blebs. Further follow-up is needed to determine long-term outcomes
Supported ionic liquid phase (SILP) materials for removal of hazardous gas compounds – efficient and irreversible NH3 adsorption
Novel supported ionic liquid phase (SILP) gas purification materials have been developed to remove ammonia irreversibly from an ambient gas flow of nitrogen (1000 ppm NH3 in N2, wet and dry). In the applied SILP materials, thin films of imidazolium based ionic liquids and ionic solutions of metal complexes, namely [C8C1Im][NTf2], [C8C1Im][NTf2]/Cu(NTf2)2, [C8C1Im][NTf2]/Co(NTf2)2 and [CnC1Im]Cl/CuCl2 (n = 2, 4, 8), were dispersed onto the large surface area of polymer-based spherical activated carbon supports. For the [CnC1Im]Cl/CuCl2 (n = 2, 4, 8) based SILP materials the use of a humid gas flow significantly enhances NH3 absorption as demonstrated by a clear increase of breakthrough times. The irreversibility of the ammonia sorption and the broadband capability (e.g. Cl2, H2S and cyclohexane) of the prepared SILP absorber materials are reported and compared to typical standards for gas purification adsorber materials (ABEK regulations)
The HYLAN M Study: Efficacy of 0.15% High Molecular Weight Hyaluronan Fluid in the Treatment of Severe Dry Eye Disease in a Multicenter Randomized Trial
The aim of the HYLAN M study was to investigate if symptoms and/or signs of patients
suffering from severe dry eye disease (DED) can be improved by substituting individually optimized
artificial tear therapy by high molecular weight hyaluronan (HMWHA) eye drops. In this international,
multicenter study, patients with symptoms of at least ocular surface disease index (OSDI) 33 and
corneal fluorescein staining (CFS) of at least Oxford grade 3 were included. A total of 84 per-protocol
patients were randomized in two study arms. The control group continued to use their individual
optimum artificial tears over the study period of eight weeks; in the verum group, the artificial tears
were substituted by eye drops containing 0.15% HMWHA. At the week 8 visit, the average OSDI
of the verum group had improved by 13.5 as compared to the control group (p = 0.001). The best
corrected visual acuity (BCVA) had improved by 0.04 logMAR (p = 0.033). CFS, tear film break-up
time (TBUT), Schirmer I, lid wiper epitheliopathy (LWE), mucocutaneous junction (Yamaguchi score),
and tear osmolarity were not significantly different between the verum and control groups (p > 0.050). We conclude that for most patients with severe DED, 0.15% HMWHA eye drops provide excellent
improvement of symptoms without impairment of dry eye signs
- …