11 research outputs found

    Versatile and scalable fabrication method for laser-generated focused ultrasound transducers

    Get PDF
    A versatile and scalable fabrication method for laser-generated focused ultrasound transducers is proposed. The method is based on stamping a coated negative mold onto polydimethylsiloxane, and it can be adapted to include different optical absorbers that are directly transferred or synthesized in situ. Transducers with a range of sizes down to 3 mm in diameter are presented, incorporating two carbonaceous (multiwalled carbon nanoparticles and candle soot nanoparticles) and one plasmonic (gold nanoparticles) optically absorbing component. The fabricated transducers operate at central frequencies in the vicinity of 10 MHz with bandwidths in the range of 15–20 MHz. A transducer with a diameter of 5 mm was found to generate a positive peak pressure greater than 35 MPa in the focal zone with a tight focal spot of 150 μm in lateral width. Ultrasound cavitation on the tip of an optical fiber was demonstrated in water for a transducer with a diameter as small as 3 mm

    Modelling and measurement of laser-generated focused ultrasound: Can interventional transducers achieve therapeutic effects?

    Get PDF
    Laser-generated focused ultrasound (LGFU) transducers used for ultrasound therapy commonly have large diameters (6–15 mm), but smaller lateral dimensions (<4 mm) are required for interventional applications. To address the question of whether miniaturized LGFU transducers could generate sufficient pressure at the focus to enable therapeutic effects, a modelling and measurement study is performed. Measurements are carried out for both linear and nonlinear propagation for various illumination schemes and compared with the model. The model comprises several innovations. First, the model allows for radially varying acoustic input distributions on the surface of the LGFU transducer, which arise from the excitation light impinging on the curved transducer surfaces. This realistic representation of the source prevents the overestimation of the achievable pressures (shown here to be as high as 1.8 times). Second, an alternative inverse Gaussian illumination paradigm is proposed to achieve higher pressures; a 35% increase is observed in the measurements. Simulations show that LGFU transducers as small as 3.5 mm could generate sufficient peak negative pressures at the focus to exceed the cavitation threshold in water and blood. Transducers of this scale could be integrated with interventional devices, thereby opening new opportunities for therapeutic applications from inside the body

    Noise Reduction in Photoacoustic Imaging using Wavelet Transform

    Get PDF
    Fotoakustik mikroskop (Photoacoustic Microscopy, PAM) fotoakustik etki temeline dayanan ve son yıllarda geliştirilmeye başlayan hibrid bir görüntüleme tekniğidir. Optik kontrastı akustik olarak algılayan sistem yapısı sayesinde optik difüzyon sınırının ötesinde derin bir görüntülemeyi yüksek çözünürlükle sunabilmektedir. PAM sistemi ile görüntülemede kaydedilen sinyaller, sistem bileşenleri ve çevresel etkilerle gürültüye maruz kalmaktadır. Yapılan çalışmanın ilk aşamasında akustik dalga denkleminin çözümüyle oluşturulan akustik sinyal üzerine belirli oranlarda sentetik gürültüler eklenmiştir. Gürültülü sinyallere farklı ana dalgacıklar kullanılarak ayrık dalgacık dönüşümü ile filtreleme işlemi uygulanmış ve filtreleme performansının değerlendirilmesi için sinyaller üzerinde gürültü metrikleri hesaplanmıştır. İkinci aşamada, ilk aşamada elde edilen veriler doğrultusunda PA sinyallerin filtrelenmesi için uygun ana dalgacıklar seçilmiş filtrelenen sinyaller ile görüntüler oluşturularak, görüntüler üzerinde gürültü metrikleri incelenmiştir // Photoacoustic microscopy (PAM) is a hybrid imaging technique based on the photoacoustic effect and which has begun to develop in recent years. Thanks to the system structure that senses the optical contrast acoustically, it is able to present deep imaging with high resolution beyond the optical diffusion limit. Signals recorded in imaging with the PAM system are exposed to noise by system components and environmental effectcs. In the first stage of the work, a synthetic noise is added at a certain rate on the acoustic signal generated by the solution of the acoustic wave equation. Noisy signals are filtered using discrete wavelet transforms using different main wavelets and noise metrics are calculated on the signals to evaluate the filtering performance. In the second step, the noise metrics are examined on the images by generating the images with the filtered wavelet signals, which are suitable for filtering the PA signals in the direction of the data obtained in the first stage

    Development of a Fiber Laser with Independently Adjustable Properties for Optical Resolution Photoacoustic Microscopy

    Get PDF
    Photoacoustic imaging is based on the detection of generated acoustic waves through thermal expansion of tissue illuminated by short laser pulses. Fiber lasers as an excitation source for photoacoustic imaging have recently been preferred for their high repetition frequencies. Here, we report a unique fiber laser developed specifically for multiwavelength photoacoustic microscopy system. The laser is custom-made for maximum flexibility in adjustment of its parameters; pulse duration (5–10 ns), pulse energy (up to 10 μJ) and repetition frequency (up to 1 MHz) independently from each other and covers a broad spectral region from 450 to 1100 nm and also can emit wavelengths of 532, 355, and 266 nm. The laser system consists of a master oscillator power amplifier, seeding two stages; supercontinuum and harmonic generation units. The laser is outstanding since the oscillator, amplifier and supercontinuum generation parts are all-fiber integrated with custom-developed electronics and software. To demonstrate the feasibility of the system, the images of several elements of standardized resolution test chart are acquired at multiple wavelengths. The lateral resolution of optical resolution photoacoustic microscopy system is determined as 2.68 μm. The developed system may pave the way for spectroscopic photoacoustic microscopy applications via widely tunable fiber laser technologies

    Comparison of Fabrication Methods for Fiber‐Optic Ultrasound Transmitters Using Candle‐Soot Nanoparticles

    Get PDF
    Candle-soot nanoparticles (CSNPs) have shown great promise for fabricating optical ultrasound (OpUS) transmitters. They have a facile, inexpensive synthesis whilst their unique, porous structure enables a fast heat diffusion rate which aids high-frequency ultrasound generation necessary for high-resolution clinical imaging. These composites have demonstrated high ultrasound generation performance showing clinically relevant detail, when applied as macroscale OpUS transmitters comprising both concave and planar surfaces, however, less research has been invested into the translation of this material's technology to fabricate fiber-optic transmitters for image guidance of minimally invasive interventions. Here, are reported two fabrication methods of nanocomposites composed of CSNPs embedded within polydimethylsiloxane (PDMS) deposited onto fiber-optic end-faces using two different optimized fabrication methods: “All-in-One” and “Direct Deposition.” Both types of nanocomposite exhibit a smooth, black domed structure with a maximum dome thickness of 50 µm, broadband optical absorption (>98% between 500 and 1400 nm) and both nanocomposites generated high peak-to-peak ultrasound pressures (>3 MPa) and wide bandwidths (>29 MHz). Further, high-resolution (<40 µm axial resolution) B-mode ultrasound imaging of ex vivo lamb brain tissue demonstrating how CSNP-PDMS OpUS transmitters can allow for high fidelity minimally invasive imaging of biological tissues is demonstrated

    A novel fiber laser development for photoacoustic microscopy

    Get PDF
    Photoacoustic microscopy, as an imaging modality, has shown promising results in imaging angiogenesis and cutaneous malignancies like melanoma, revealing systemic diseases including diabetes, hypertension, tracing drug efficiency and assessment of therapy, monitoring healing processes such as wound cicatrization, brain imaging and mapping. Clinically, photoacoustic microscopy is emerging as a capable diagnostic tool. Parameters of lasers used in photoacoustic microscopy, particularly, pulse duration, energy, pulse repetition frequency, and pulse-to-pulse stability affect signal amplitude and quality, data acquisition speed and indirectly, spatial resolution. Lasers used in photoacoustic microscopy are typically Q-switched lasers, low-power laser diodes, and recently, fiber lasers. Significantly, the key parameters cannot be adjusted independently of each other, whereas microvasculature and cellular imaging, e.g., have different requirements. Here, we report an integrated fiber laser system producing nanosecond pulses, covering the spectrum from 600 nm to 1100 nm, developed specifically for photoacoustic excitation. The system comprises of Yb-doped fiber oscillator and amplifier, an acousto-optic modulator and a photonic-crystal fiber to generate supercontinuum. Complete control over the pulse train, including generation of non-uniform pulse trains, is achieved via the AOM through custom-developed field-programmable gate-array electronics. The system is unique in that all the important parameters are adjustable: pulse duration in the range of 1-3 ns, pulse energy up to 10 μJ, repetition rate from 50 kHz to 3 MHz. Different photocoustic imaging probes can be excited with the ultrabroad spectrum. The entire system is fiber-integrated; guided-beam-propagation rendersit misalignment free and largely immune to mechanical perturbations. The laser is robust, low-cost and built using readily available components. © 2013 Copyright SPIE

    Development of a Fiber Laser with Independently Adjustable Properties for Optical Resolution Photoacoustic Microscopy

    Get PDF
    Photoacoustic imaging is based on the detection of generated acoustic waves through thermal expansion of tissue illuminated by short laser pulses. Fiber lasers as an excitation source for photoacoustic imaging have recently been preferred for their high repetition frequencies. Here, we report a unique fiber laser developed specifically for multiwavelength photoacoustic microscopy system. The laser is custom-made for maximum flexibility in adjustment of its parameters; pulse duration (5-10 ns), pulse energy (up to 10 μJ) and repetition frequency (up to 1 MHz) independently from each other and covers a broad spectral region from 450 to 1100 nm and also can emit wavelengths of 532, 355, and 266 nm. The laser system consists of a master oscillator power amplifier, seeding two stages; supercontinuum and harmonic generation units. The laser is outstanding since the oscillator, amplifier and supercontinuum generation parts are all-fiber integrated with custom-developed electronics and software. To demonstrate the feasibility of the system, the images of several elements of standardized resolution test chart are acquired at multiple wavelengths. The lateral resolution of optical resolution photoacoustic microscopy system is determined as 2.68 μm. The developed system may pave the way for spectroscopic photoacoustic microscopy applications via widely tunable fiber laser technologies. © The Author(s) 2016

    Comparison of Fabrication Methods for Fiber‐Optic Ultrasound Transmitters Using Candle‐Soot Nanoparticles

    Get PDF
    Candle-soot nanoparticles (CSNPs) have shown great promise for fabricating optical ultrasound (OpUS) transmitters. They have a facile, inexpensive synthesis whilst their unique, porous structure enables a fast heat diffusion rate which aids high-frequency ultrasound generation necessary for high-resolution clinical imaging. These composites have demonstrated high ultrasound generation performance showing clinically relevant detail, when applied as macroscale OpUS transmitters comprising both concave and planar surfaces, however, less research has been invested into the translation of this material's technology to fabricate fiber-optic transmitters for image guidance of minimally invasive interventions. Here, are reported two fabrication methods of nanocomposites composed of CSNPs embedded within polydimethylsiloxane (PDMS) deposited onto fiber-optic end-faces using two different optimized fabrication methods: “All-in-One” and “Direct Deposition.” Both types of nanocomposite exhibit a smooth, black domed structure with a maximum dome thickness of 50 µm, broadband optical absorption (>98% between 500 and 1400 nm) and both nanocomposites generated high peak-to-peak ultrasound pressures (>3 MPa) and wide bandwidths (>29 MHz). Further, high-resolution (<40 µm axial resolution) B-mode ultrasound imaging of ex vivo lamb brain tissue demonstrating how CSNP-PDMS OpUS transmitters can allow for high fidelity minimally invasive imaging of biological tissues is demonstrated

    Comparison of Fabrication Methods for Fiber‐Optic Ultrasound Transmitters Using Candle‐Soot Nanoparticles

    No full text
    Abstract Candle‐soot nanoparticles (CSNPs) have shown great promise for fabricating optical ultrasound (OpUS) transmitters. They have a facile, inexpensive synthesis whilst their unique, porous structure enables a fast heat diffusion rate which aids high‐frequency ultrasound generation necessary for high‐resolution clinical imaging. These composites have demonstrated high ultrasound generation performance showing clinically relevant detail, when applied as macroscale OpUS transmitters comprising both concave and planar surfaces, however, less research has been invested into the translation of this material's technology to fabricate fiber‐optic transmitters for image guidance of minimally invasive interventions. Here, are reported two fabrication methods of nanocomposites composed of CSNPs embedded within polydimethylsiloxane (PDMS) deposited onto fiber‐optic end‐faces using two different optimized fabrication methods: “All‐in‐One” and “Direct Deposition.” Both types of nanocomposite exhibit a smooth, black domed structure with a maximum dome thickness of 50 µm, broadband optical absorption (>98% between 500 and 1400 nm) and both nanocomposites generated high peak‐to‐peak ultrasound pressures (>3 MPa) and wide bandwidths (>29 MHz). Further, high‐resolution (<40 µm axial resolution) B‐mode ultrasound imaging of ex vivo lamb brain tissue demonstrating how CSNP‐PDMS OpUS transmitters can allow for high fidelity minimally invasive imaging of biological tissues is demonstrated
    corecore