    Effects of three silane primers and five adhesive agents on the bond strength of composite material for a computer-aided design and manufacturing system

    Get PDF
    Objective: The objective of this study was to evaluate the effects of combinations of silane primers and adhesive agents on the bond strength of a composite block for a computer-aided design and manufacturing system. Material and Methods: Three silane primers [Clearfil Ceramic Primer (CP), Super-Bond PZ Primer (PZ), and GC Ceramic Primer II (GP)] were used in conjunction with five adhesive agents [G-Premio Bond (P-Bond), Repair Adhe Adhesive (R-Adhesive), Super-Bond D-Liner Dual (SB-Dual), Super-Bond C&B (SB-Self), and SB-Dual without tributylborane derivative (SB-Light)]. The surface of a composite block (Gradia Block) was ground with silicon carbide paper. After treatment with a silane primer, a adhesive agent was applied to each testing specimen. The specimens were then bonded with a light-curing resin composite. After 24 h, the shear bond strength values were determined and compared using a post hoc test (α=0.05, n=8/group). We also prepared control specimens without primer (No primer) and/or without adhesive agent (No adhesive). Results:PZ/SB-Dual and GP/SB-Dual presented the highest bond strength, followed by GP/P-Bond, CP/SB-Dual, CP/R-Adhesive, No primer/SB-Dual, GP/R-Adhesive, CP/P-Bond, No primer/R-Adhesive, PZ/R-Adhesive, CP/SB-Self, PZ/P-Bond, PZ/SB-Self, and GP/SB-Self in descending order of bond strength. No primer/P-Bond, No primer/SB-Self, and all specimens in the SB-Light and No adhesive groups presented the lowest bond strengths. Conclusion: A dual-curing adhesive agent (SB-Dual) containing a tributylborane derivative in combination with a silane primer (GP or PZ) presents a greater bond strength between the composite block and the repairing resin composite than the comparators used in the study

    Effects of three silane primers and five adhesive agents on the bond strength of composite material for a computer-aided design and manufacturing system

    Get PDF
    Objective: The objective of this study was to evaluate the effects of combinations of silane primers and adhesive agents on the bond strength of a composite block for a computer-aided design and manufacturing system. Material and Methods: Three silane primers [Clearfil Ceramic Primer (CP), Super-Bond PZ Primer (PZ), and GC Ceramic Primer II (GP)] were used in conjunction with five adhesive agents [G-Premio Bond (P-Bond), Repair Adhe Adhesive (R-Adhesive), Super-Bond D-Liner Dual (SB-Dual), Super-Bond C&B (SB-Self), and SB-Dual without tributylborane derivative (SB-Light)]. The surface of a composite block (Gradia Block) was ground with silicon carbide paper. After treatment with a silane primer, a adhesive agent was applied to each testing specimen. The specimens were then bonded with a light-curing resin composite. After 24 h, the shear bond strength values were determined and compared using a post hoc test (α=0.05, n=8/group). We also prepared control specimens without primer (No primer) and/or without adhesive agent (No adhesive). Results: PZ/SB-Dual and GP/SB-Dual presented the highest bond strength, followed by GP/P-Bond, CP/SB-Dual, CP/R-Adhesive, No primer/SB-Dual, GP/R-Adhesive, CP/P-Bond, No primer/RAdhesive, PZ/R-Adhesive, CP/SB-Self, PZ/P-Bond, PZ/SB-Self, and GP/SB-Self in descending order of bond strength. No primer/P-Bond, No primer/SB-Self, and all specimens in the SB-Light and No adhesive groups presented the lowest bond strengths. Conclusion: A dual-curing adhesive agent (SB-Dual) containing a tributylborane derivative in combination with a silane primer (GP or PZ) presents a greater bond strength between the composite block and the repairing resin composite than the comparators used in the study

    Effects of cleaning methods for custom abutment surfaces on gene expression of human gingival fibroblasts

    Get PDF
    The aim of this study was to develop an effective method for cleaning implant abutments made by computer-aided design and computer-aided manufacturing techniques and to investigate the effect of decontamination in vitro. Briefly, a newly developed reagent (PK) and/or vacuum plasma (Plasma) were used to clean the surfaces of zirconia disks, and the effects of this decontamination were evaluated by X-ray photoelectron spectroscopy. Human gingival fibroblasts (HGFs) were cultured on sample disks for 6, 24, and 48 h. We evaluated cell attachment and gene expression of the acute inflammatory cytokines interleukin-6 and vascular endothelial growth factor A, and type 1 collagen. In the PK and PK+Plasma groups, surface contaminants were reduced by washing. In addition, HGF attachments was increased in the PK and PK+Plasma groups. Gene expressions of interleukin-6 and vascular endothelial growth factor A were lower at 6 h. Gene expression of type 1 collagen was increased at all time points after seeding. These results suggest that decontamination of implant abutment surfaces is important in initial HGF attachment and may improve the biological seal of peri-implant soft tissue

    Effects of three silane primers and five adhesive agents on the bond strength of composite material for a computer-aided design and manufacturing system

    No full text
    <div><p>Abstract Objective The objective of this study was to evaluate the effects of combinations of silane primers and adhesive agents on the bond strength of a composite block for a computer-aided design and manufacturing system. Material and Methods Three silane primers [Clearfil Ceramic Primer (CP), Super-Bond PZ Primer (PZ), and GC Ceramic Primer II (GP)] were used in conjunction with five adhesive agents [G-Premio Bond (P-Bond), Repair Adhe Adhesive (R-Adhesive), Super-Bond D-Liner Dual (SB-Dual), Super-Bond C&B (SB-Self), and SB-Dual without tributylborane derivative (SB-Light)]. The surface of a composite block (Gradia Block) was ground with silicon carbide paper. After treatment with a silane primer, a adhesive agent was applied to each testing specimen. The specimens were then bonded with a light-curing resin composite. After 24 h, the shear bond strength values were determined and compared using a post hoc test (α=0.05, n=8/group). We also prepared control specimens without primer (No primer) and/or without adhesive agent (No adhesive). Results PZ/SB-Dual and GP/SB-Dual presented the highest bond strength, followed by GP/P-Bond, CP/SB-Dual, CP/R-Adhesive, No primer/SB-Dual, GP/R-Adhesive, CP/P-Bond, No primer/R-Adhesive, PZ/R-Adhesive, CP/SB-Self, PZ/P-Bond, PZ/SB-Self, and GP/SB-Self in descending order of bond strength. No primer/P-Bond, No primer/SB-Self, and all specimens in the SB-Light and No adhesive groups presented the lowest bond strengths. Conclusion A dual-curing adhesive agent (SB-Dual) containing a tributylborane derivative in combination with a silane primer (GP or PZ) presents a greater bond strength between the composite block and the repairing resin composite than the comparators used in the study.</p></div

    Efficacy and safety of an Aron Alpha method in managing giant ovarian tumors

    No full text
    Background: Giant malignant tumors have an increased risk of intraoperative rupture, which might lead to a worse disease condition and tumor recurrence. We performed a clinical study on patients with a giant ovarian mass who underwent laparoscopy combined with an Aron Alpha method. Methods: This retrospective clinical study spanned from January 2016 to September 2022 and included 23 patients with giant ovarian tumors treated with an Aron Alpha method. Results: The mean age of the subjects was 47.6 ± 17.8 years, mean tumor diameter 20.4 ± 5.8 cm, mean surgical duration 87.2 ± 33.1  min, and mean hemorrhage volume 94.1 ± 92.2 mL. No patient experienced intraoperative tumor rupture or surgery-related symptoms. Histopathology of excised samples revealed serous cyst adenoma and mucinous cystadenoma, mucinous cystadenoma of borderline malignancy and mature cystic teratoma, and endometriotic cyst adenoma in 6, 4, and 3 patients, respectively. The mean hospitalization period was 6.0 ± 1.2 days, and the hospitalization period was not extended in any subject. Conclusion: The Aron Alpha method allows tumor resection without capsular rupture and is a useful, minimally invasive surgical method for resecting giant ovarian tumors in which malignancy cannot be ruled out

    Myoma with Hypermenorrhea Treated with Ultrasound-Guided Microwave Ablation of the Inflowing Blood Vessels to the Uterine Myoma: A Case

    No full text
    Microwave endometrial ablation (MEA) is a minimally invasive treatment for uterine myoma with hypermenorrhea, which can replace conventional hysterectomy. However, cases requiring additional treatment because of postoperative recurrence are often encountered. MEA cauterizes the endometrium and is not recommended for patients who wish to preserve fertility. We present the cases of a patient with myoma-related hypermenorrhea who underwent microwave ablation of the inflowing blood vessels to the uterine myoma under transvaginal ultrasound guidance. A 43-year-old woman was diagnosed with chronic myeloid leukemia and treated with dasatinib 2 years ago. Worsening hypermenorrhea was observed after treatment initiation. Ultrasound and pelvic magnetic resonance imaging revealed a uterine myoma. Therefore, she underwent MEA under transvaginal ultrasound guidance. Visual analog scale evaluation demonstrated considerable improvement in hypermenorrhea and dysmenorrhea; the myoma size showed reduction. The postoperative course was uneventful, and the patient was discharged on the day after surgery. No postoperative complications were observed. This patient is currently undergoing infertility treatment. The microwave ablation of myoma under transvaginal ultrasound guidance can effectively and safely reduce the myoma size. These findings suggest that this method is a novel treatment option for patients with myoma-related hypermenorrhea who wish to preserve their fertility and have children

    Myoma with Hypermenorrhea Treated with Ultrasound-Guided Microwave Ablation of the Inflowing Blood Vessels to the Uterine Myoma: A Case

    No full text
    Microwave endometrial ablation (MEA) is a minimally invasive treatment for uterine myoma with hypermenorrhea, which can replace conventional hysterectomy. However, cases requiring additional treatment because of postoperative recurrence are often encountered. MEA cauterizes the endometrium and is not recommended for patients who wish to preserve fertility. We present the cases of a patient with myoma-related hypermenorrhea who underwent microwave ablation of the inflowing blood vessels to the uterine myoma under transvaginal ultrasound guidance. A 43-year-old woman was diagnosed with chronic myeloid leukemia and treated with dasatinib 2 years ago. Worsening hypermenorrhea was observed after treatment initiation. Ultrasound and pelvic magnetic resonance imaging revealed a uterine myoma. Therefore, she underwent MEA under transvaginal ultrasound guidance. Visual analog scale evaluation demonstrated considerable improvement in hypermenorrhea and dysmenorrhea; the myoma size showed reduction. The postoperative course was uneventful, and the patient was discharged on the day after surgery. No postoperative complications were observed. This patient is currently undergoing infertility treatment. The microwave ablation of myoma under transvaginal ultrasound guidance can effectively and safely reduce the myoma size. These findings suggest that this method is a novel treatment option for patients with myoma-related hypermenorrhea who wish to preserve their fertility and have children