21 research outputs found

    Measurement of the mean central optical depth of galaxy clusters via the pairwise kinematic Sunyaev-Zel'dovich effect with SPT-3G and des

    Get PDF
    We infer the mean optical depth of a sample of optically selected galaxy clusters from the Dark Energy Survey via the pairwise kinematic Sunyaev-Zel'dovich (KSZ) effect. The pairwise KSZ signal between pairs of clusters drawn from the Dark Energy Survey Year-3 cluster catalog is detected at 4.1σ in cosmic microwave background temperature maps from two years of observations with the SPT-3G camera on the South Pole Telescope. After cuts, there are 24,580 clusters in the ∼1,400 deg2 of the southern sky observed by both experiments. We infer the mean optical depth of the cluster sample with two techniques. The optical depth inferred from the pairwise KSZ signal is τ¯e=(2.97±0.73)×10-3, while that inferred from the thermal SZ signal is τ¯e=(2.51±0.55stat±0.15syst)×10-3. The two measures agree at 0.6σ. We perform a suite of systematic checks to test the robustness of the analysis

    Measurements of B-mode polarization of the cosmic microwave background from 500 square degrees of SPTpol data

    Get PDF
    We report a B-mode power spectrum measurement from the cosmic microwave background (CMB) polarization anisotropy observations made using the SPTpol instrument on the South Pole Telescope. This work uses 500 deg2 of SPTpol data, a five-fold increase over the last SPTpol B-mode release. As a result, the bandpower uncertainties have been reduced by more than a factor of two, and the measurement extends to lower multipoles: 52320

    Pulse-chase analysis for studies of MHC class II biosynthesis, maturation, and peptide loading

    No full text
    Pulse-chase analysis is a commonly used technique for studying the synthesis, processing and transport of proteins. Cultured cells expressing proteins of interest are allowed to take up radioactively labeled amino acids for a brief interval (“pulse”), during which all newly synthesized proteins incorporate the label. The cells are then returned to non-radioactive culture medium for various times (“chase”), during which proteins may undergo conformational changes, trafficking, or degradation. Proteins of interest are isolated (usually by immunoprecipitation) and resolved by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), and the fate of radiolabeled molecules is examined by autoradiography. This chapter describes a pulse-chase protocol suitable for studies of major histocompatibility complex (MHC) class II biosynthesis and maturation. We discuss how results are affected by the recognition by certain anti-class II antibodies of distinct class II conformations associated with particular biosynthetic states. Our protocol can be adapted to follow the fate of many other endogenously synthesized proteins, including viral or transfected gene products, in cultured cells

    An Improved Measurement of the Secondary Cosmic Microwave Background Anisotropies from the SPT-SZ plus SPTpol Surveys

    No full text
    Abstract We report new measurements of millimeter-wave power spectra in the angular multipole range 2000 ≤ ℓ ≤ 11,000 (angular scales ). By adding 95 and 150 GHz data from the low-noise 500 deg2 SPTpol survey to the SPT-SZ three-frequency 2540 deg2 survey, we substantially reduce the uncertainties in these bands. These power spectra include contributions from the primary cosmic microwave background, cosmic infrared background, radio galaxies, and thermal and kinematic Sunyaev–Zel’dovich (SZ) effects. The data favor a thermal SZ (tSZ) power at 143 GHz of and a kinematic SZ (kSZ) power of . This is the first measurement of kSZ power at ≥3σ. However, different assumptions about the CIB or SZ models can reduce the significance down to 2.4σ in the worst case. We study the implications of the measured kSZ power for the epoch of reionization under the Calabrese et al. model for the kSZ power spectrum and find the duration of reionization to be ( at 95% confidence), when combined with our previously published tSZ bispectrum measurement. The upper limit tightens to if the assumed homogeneous kSZ power is increased by 25% (∼0.5 μK2) and relaxes to if the homogeneous kSZ power is decreased by the same amount
    corecore