54 research outputs found

    Characteristics presented by patients on their first appointment at the Glaucoma Sector of Universidade Federal de São Paulo (UNIFESP) - UNIFESP

    Get PDF
    PURPOSE: To evaluate characteristics of glaucoma patients at our university hospital facility. METHODS: This is a retrospective study that shows comprehensive clinical factors presented by patients on their first appointment at the Universidade Federal de São Paulo (UNIFESP) - UNIFESP Glaucoma Department, from January 2000 through January 2001. The data originated from a social, demographic and comprehensive analysis of our prerecorded files. RESULTS: The group consisted of elderly people, mostly Caucasian, female, married and retired, or with a domestic lifestyle, about 89% from the state of São Paulo. It was observed that 928 (56.44%) of the studied eyes presented visual acuity lower than 1.0 logMAR and that 689 (41.9%) of the studied eyes displayed visual acuity above or equal to 1.0 logMAR. The advanced optic-disk cup, above or equal to 0.8, was found in 42.03% of the studied eyes. A significant number of patients displayed advanced pathological conditions. CONCLUSIONS: It was observed that 41.9% of the cases presented blindness in one eye from the very onset, and that 42.03% of the eyes presented advanced cup above or equal to 0.8, suggesting advanced glaucoma.OBJETIVO: Avaliar as características clínicas dos pacientes portadores de glaucoma em um serviço universitário de referência. MÉTODOS: Realizou-se um estudo retrospectivo e descritivo de 822 prontuários de pacientes atendidos pela primeira vez no Setor de Glaucoma da Universidade Federal de São Paulo (UNIFESP) - UNIFESP, no período de janeiro de 2000 a janeiro de 2001. Os dados obtidos de cada paciente foram oriundos de uma avaliação dos prontuários destes pacientes. Avaliaram-se alguns dados sociodemográficos e características clínicas dos pacientes glaucomatosos deste setor. RESULTADOS: A amostra era composta, em sua maioria, por pacientes idosos, brancos, femininos, casados e aposentados ou do lar, com cerca de 89,65% procedentes do estado de São Paulo. Encontrou-se neste estudo, 56,44% dos olhos avaliados com acuidade visual menor que 1,0 logMAR. Os casos com acuidade visual maior ou igual a 1,0 logMAR corresponderam a 41,9% dos olhos. A escavação do disco óptico já se encontrava avançada (maior ou igual a 0,8) em 691 (42,03%) olhos, sendo que em 324 (19,7%) existia uma escavação total do nervo óptico. CONCLUSÃO: Observou-se que o número de pacientes em estado avançado da doença era considerável, e que 41,90% dos pacientes atendidos pela primeira vez apresentavam cegueira em pelo menos um dos olhos e que 42,03% apresentavam escavações do disco óptico maiores ou iguais que 0,8, sugerindo casos avançados de glaucoma.Universidade Federal de São Paulo (UNIFESP) Setor de GlaucomaUNIFESP, Setor de GlaucomaSciEL

    Ciclopexia direta em ciclodiálise pós-traumática com hipotonia ocular persistente -acompanhamento por biomicroscopia ultrassônica (UBM)

    Get PDF
    Cyclodialysis is a relatively rare condition usually caused by ocular injury; however, it can also be caused iatrogenically during intraocular surgery. Hypotony maculopathy is the most important complication and the primary reason for visual loss. Clinical diagnosis using gonioscopy may be difficult, and ultrasound biomicroscopy (UBM) can be an alternative. There are different kinds of treatments, and the optimal one remains controversial. Here we describe a case of traumatic cyclodialysis with persistent ocular hypotony treated by direct cyclopexy, as illustrated by UBM performed before and after surgery.Ciclodiálise é uma condição relativamente rara, geralmente devido a um trauma ocular, mas também pode ser causada iatrogenicamente como consequência de cirurgia intraocular. A maculopatia hipotônica é a complicação mais importante e a principal razão para a perda visual nessa situação. O diagnóstico clínico por gonioscopia pode ser difícil e a biomicroscopia ultrassônica (UBM) pode ser uma alternativa. Existem diferentes tipos de tratamentos e algumas controvérsias sobre a melhor opção. Neste relato, nós descrevemos um caso de ciclodiálise traumática com hipotonia ocular persistente tratado por cyclopexia direta avaliado por UBM antes e depois da cirurgia.Universidade Federal de São Paulo (UNIFESP) Department of Ophthalmology Ocular Trauma sectionUniversidade Federal de São Paulo (UNIFESP) Department of Ophthalmology Glaucoma sectionUNIFESP, Department of Ophthalmology Ocular Trauma sectionUNIFESP, Department of Ophthalmology Glaucoma sectionSciEL

    Ausência de mudança no ritmo circadiano da concentração de peptídeo natriurético tipo C no humor aquoso de coelhos

    Get PDF
    PURPOSE: To determine whether there is a circadian change of the concentration of C-type natriuretic peptide (CNP) in rabbit aqueous humor. METHODS: Forty-one male white New Zealand rabbits were submitted to a 12 h light and 12 dark lighting schedule; lights on was at 0 h, lights off at 12 h. C-type natriuretic peptide was assayed at 3 light (2 h, 6 h and 10 h) and 3 dark (14,18 and 22 h) times. All groups consisted of four animals but two had more animals to increase the power of tests (6 h, n=12; 22 h, n=13). Dependence between the two eyes was tested by Pearson's correlation. The mean of two eyes was considered for analysis. Differences in concentration in pg/200 ml were evaluated by one-way ANOVA, t test and COSINOR analysis. RESULTS: There were no significant differences between the 6 analyzed groups (one-way ANOVA p=0.157). Pooled into two groups (light and dark), the C-type natriuretic peptide concentration of the light group was lower, 2.626±0.92 pg/200 ml compared with the dark group 3.02±1.16 pg/200 ml but did not reach a significant difference (t test; p=0.23). COSINOR analysis was not statistically significant (R%=7.72 p=0.209). CONCLUSION: These data demonstrate that the concentration of CNP in aqueous humor did not show a statistically significant circadian change in rabbits entrained to a 12 h light: 12 h dark lighting schedule.OBJETIVO: Verificar se há mudança na concentração circadiana de peptídeo natriurético tipo C (CNP) no humor aquoso de coelhos. MÉTODOS: Quarenta e um coelhos machos da raça New Zealand foram admitidos numa rotina de 12 horas de luz e 12 de escuridão; luzes eram acesas na hora zero e apagadas na hora 12. O peptídeo natriurético tipo C era medido em três períodos com luz acesa (2, 6 e 10 h) e 3 com luz apagada (14, 18 e 22 h). Todos os grupos tinham 4 animais com exceção de dois períodos em que o n foi incrementado para aumentar o poder dos testes (6 h, n=12; 22 h, n=13). A dependência entre os olhos foi testada por meio da correlação de Pearson. A média dos dois olhos foi usada para a análise. Diferença quanto à concentração média de peptídeo natriurético tipo C em pg/200 ml foi avaliada por meio do teste de one-way ANOVA, teste t e análise de COSINOR. RESULTADOS: Não foi encontrada diferença estatisticamente significante entre os 6 grupos analisados (one-way ANOVA; p=0,157). Reunidos em dois grupos (luz e escuridão), a concentração de peptídeo natriurético tipo C com a luz acesa foi mais baixa (2,626±0,92 pg/200 ml) quando comparada ao grupo com luz apagada (3,02±1,16 pg/200 ml) porém sem alcançar significância estatística (teste de t p=0,23). Análise de COSINOR não foi estatisticamente significante (R%=7,72 p=0,209). CONCLUSÃO: Nossos dados demonstraram que a concentração do CNP no humor aquoso de coelhos não mostrou variação circadiana estatisticamente significante quando analisadas num ritmo de luz/escuro 12/12 h.Universidade Federal de São Paulo (UNIFESP) Setor de GlaucomaUniversidade de YALEUNIFESP Departamento de OftalmologiaUNIFESP, Setor de GlaucomaUNIFESP, Depto. de OftalmologiaSciEL

    Frequency doubling technology in patients submitted to laser-assisted in situ keratomileusis (LASIK): cost-benefit analysis

    Get PDF
    PURPOSE: To check if there is functional damage to magnocellular cells using the frequency doubling technology (FDT), after laser assisted in situ keratomileusis-LASIK intraocular pressure increase and to analyze the benefit of this test in patients undergoing refractive surgery, regarding involved costs. METHODS: Prospective study in 19 ametropic patients undergoing refractive laser assisted in situ keratomileusis surgery, at the Hospital Oftalmológico de Sorocaba. Two frequency doubling technology examinations were performed in both eyes of patients before LASIK and one examination was done after the surgery. The assessment of the difference between the measurements of MD (Delta MD) was considered the dependent variable to formulate an evaluation of multiple regression. The costs of the frequency doubling technology and LASIK were analyzed. RESULTS: There was no difference between the MD (mean deviation) and PSD (pattern standard deviation) before and after the procedure (p= 0.4454 and p= 0.9716, respectively). The continuous variables did not significantly influence Delta MD (r²= 4.1%; F= 0.15; p= 0.96). We considered 1500 LASIK surgeries during one year at the Hospital Oftalmológico de Sorocaba, and the average cost of this surgery is R373.27.ThefrequencydoublingtechnologycostsR 373.27. The frequency doubling technology costs R 13.15 for each patient. CONCLUSIONS: There was no statistically significant difference between MD and PSD (pattern standard deviation) before and after the surgery. The frequency doubling technology has high sensitivity and specificity and low cost, so it could be used in patients undergoing refractive surgery (high cost) to avoid the laser assisted in situ keratomileusis in glaucoma patients.OBJETIVO: Verificar existência de alteração funcional das células magnocelulares por meio da tecnologia de freqüência duplicada (FDT), após o incremento de pressão gerado pela técnica de laser assisted in situ keratomileusis (LASIK), e avaliar os benefícios de realizar este em pacientes candidatos à cirurgia refrativa, considerando-se os custos envolvidos nos procedimentos. MÉTODOS: Estudo prospectivo em 19 pacientes com ametropias, submetidos à cirurgia laser assisted in situ keratomileusis, no Hospital Oftalmológico de Sorocaba. Foram realizados 2 exames de tecnologia de freqüência duplicada em ambos os olhos dos pacientes antes da cirurgia por laser assisted in situ keratomileusis, e um exame após a cirurgia. A avaliação da diferença entre as medidas de MD (mean deviation) e PSD (pattern standard deviation) efetuadas pela tecnologia de freqüência duplicada antes e depois da cirurgia refrativa foram avaliadas por meio do teste de t pareado. A diferença entre as medidas de MD (Delta MD) foi considerada variável dependente para elaborações de uma avaliação de regressão múltipla. Foi realizada uma análise de custos do exame de tecnologia de freqüência duplicada e da cirurgia laser assisted in situ keratomileusis. RESULTADOS: Não houve diferença entre as medidas de MD no exame de tecnologia de freqüência duplicada antes e após o procedimento (p= 0,4454) assim como para PSD (p= 0,9716). Nenhuma variável contínua testada influiu significantemente no Delta MD (r²= 4,1%; F= 0,15; p= 0,960). Considerando a realização de 1500 cirurgias de laser assisted in situ keratomileusis ao ano no Hospital Oftalmológico de Sorocaba, o custo médio desta cirurgia é de R373,27eocustodoexamedetecnologiadefrequ¨e^nciaduplicadaeˊdeR 373,27 e o custo do exame de tecnologia de freqüência duplicada é de R 13,15 por paciente. CONCLUSÕES: Não houve diferença estatisticamente significante entre as medidas de MD no exame de tecnologia de freqüência duplicada antes e após o procedimento assim como para PSD. A tecnologia de freqüência duplicada, exame com alta sensibilidade e especificidade, e de baixo custo poderia ser utilizado como exame pré-operatório em pacientes submetidos à cirurgia refrativa (LASIK), de alto custo, com o propósito de evitar tal procedimento em pacientes com glaucoma.Universidade Federal de São Paulo (UNIFESP)Hospital Oftalmológico de Sorocaba Departamento de GlaucomaHospital Oftalmológico de SorocabaUniversidade Federal de São Paulo (UNIFESP) Departamento de GlaucomaUNIFESP, Depto. de GlaucomaSciEL

    Razão escavação/disco simulada: uma ferramenta para oftalmologistas

    Get PDF
    PURPOSE: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. METHODS: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. RESULTS: There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). CONCLUSION: Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.OBJETIVO: Avaliar e comparar a habilidade de observadores em medir a razão escavação/disco (CDR) por meio de figuras esquemáticas. MÉTODOS: Em um estudo prospectivo, randomizado e mascarado, 43 imagens representado CDR horizontais e verticais entre 0,2 e 0,9 foram desenvolvidas e apresentadas em uma tela de computador para 171 participantes. RESULTADOS: Para todos os intervalos de CDR a concordância foi satisfatória para análise kappa (0,755 e 0,730 para CDR horizontais e verticais, respectivamente) e para concordância de Lin (R=0,88 e R=0,86 para medidas horizontais e verticais respectivamente). No entanto, a concordância foi fraca para valores intermediários de CDR. A pior concordância ocorreu para CDR horizontais e verticais entre 0,4 e 0,6. CONCLUSÃO: Apesar da boa concordância geral entre as respostas corretas e as respostas dadas pelos participantes, a concordância absoluta para valores intermediários de CDR mostrou-se muito fraca tanto para figuras horizontais como verticais.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq

    Evaluation of the use of eye drops in patients with glaucoma

    Get PDF
    PURPOSE:To identify the most important variables interfering with the correct topical administration of antiglaucomatous drugs. METHODS: Forty glaucomatous patients under clinical treatment were interviewed and observed while applying antiglaucomatous drugs. The following variables were analyzed: sex; age; income; washing of the hands; number of drops; motor abnormalities; availability of another person to apply the drug; place of the globe reached; bottle-eye contact; previous instruction; positioning for application; development of a burning sensation, pain or irritation. Using the questionary, the variables were correlated with the quality of instillation. RESULTS: Among all variables, only the availability of another person to apply the drug and the existence of a burning sensation, pain or eye irritation showed statistically important correlation to proper instillation. CONCLUSION: The presence of a companion and the development of burning sensation affected the quality of instillation.OBJETIVO: Identificação das principais variáveis que interferem na qualidade de instilação correta de colírio antiglaucomatoso. MÉTODOS: Realizou-se estudo transversal em 40 pacientes glaucomatosos sob tratamento clínico com uso de colírio, aplicando-se um questionário e realizando-se observações quanto à instilação. Foram investigadas as seguintes variáveis: sexo; escolaridade; idade; condições sócioeconômicas; lavagem das mãos; número de gotas por aplicação; alteração motora; pessoa que aplica o colírio; local da aplicação; contato do frasco com as pálpebras, a conjuntiva e a córnea; instrução pregressa; posição de aplicação; ardor, dor ou irritação ocular após a aplicação e acuidade visual. A partir do questionário e das observações, as variáveis citadas foram correlacionadas com a qualidade de instilação. O modelo de análise foi a regressão logística binária. RESULTADOS: Dentre todas as variáveis em questão, apenas a pessoa que aplica o colírio e a sensação de ardor, dor ou irritação ocular mostraram-se estatisticamente significativas para uma adequada instilação de colírio. CONCLUSÃO: A presença de um acompanhante e o ardor à instilação do colírio influenciaram significativamente na qualidade de instilação do mesmo.Universidade Federal de São Paulo (UNIFESP) Departamento de OftalmologiaUniversidade Federal de São Paulo (UNIFESP) Setor de OftalmologiaUniversidade Federal de São Paulo (UNIFESP) Setor de GlaucomaUNIFESP, Depto. de OftalmologiaUNIFESP, Setor de OftalmologiaUNIFESP, Setor de GlaucomaSciEL
    • …
    corecore