451 research outputs found

    ASCA Observations of OAO 1657-415 and its Dust-Scattered X-Ray Halo

    Full text link
    We report on two ASCA observations of the high-mass X-ray binary pulsar OAO 1657-415. A short observation near mid-eclipse caught the source in a low-intensity state, with a weak continuum and iron emission dominated by the 6.4-keV fluorescent line. A later, longer observation found the source in a high-intensity state and covered the uneclipsed through mid-eclipse phases. In the high-intensity state, the non-eclipse spectrum has an absorbed continuum component due to scattering by material near the pulsar and 80 per cent of the fluorescent iron emission comes from less than 19 lt-sec away from the pulsar. We find a dust-scattered X-ray halo whose intensity decays through the eclipse. We use this halo to estimate the distance to the source as 7.1 +/- 1.3 kpc.Comment: Accepted for publication in MNRA

    LISA pathfinder micronewton cold gas thrusters: in-flight characterization

    Get PDF
    The LISA Pathfinder (LPF) mission has demonstrated the ability to limit and measure the fluctuations in acceleration between two free falling test masses down to sub-femto-g levels. One of the key elements to achieve such a level of residual acceleration is the drag free control. In this scheme the spacecraft is used as a shield against any external disturbances by adjusting its relative position to a reference test mass. The actuators used to move the spacecraft are cold gas micropropulsion thrusters. In this paper, we report in-flight characterization of these thrusters in term of noise and artefacts during science operations using all the metrology capabilities of LISA Pathfinder. Using the LISA Pathfinder test masses as an inertial reference frame, an average thruster noise of ~0.17¿¿µN/Hz is observed and decomposed into a common (coherent) and an uncorrelated component. The very low noise and stability of the onboard metrology system associated with the quietness of the space environment allowed the measurement of the thruster noise down to ~20¿¿µHz, more than an order of magnitude below any ground measurement. Spectral lines were observed around ~1.5¿¿mHz and its harmonics and around 55 and 70 mHz. They are associated with the cold gas system itself and possibly to a clock synchronization issue. The thruster noise-floor exhibits an excess of ~70% compared to characterization that have been made on ground on a single unit and without the feeding system. However this small excess has no impact on the LPF mission performance and is compatible with the noise budget for the upcoming LISA gravitational wave observatory. Over the whole mission, nominal, and extension, the thrusters showed remarkable stability for both the science operations and the different maneuvers necessary to maintain LPF on its orbit around L1. It is therefore concluded that a similar cold gas system would be a viable propulsion system for the future LISA mission.Peer ReviewedPostprint (author's final draft

    Novel methods to measure the gravitational constant in space

    Get PDF
    We present two novel methods, tested by LISA Pathfinder, to measure the gravitational constant G for the first time in space. Experiment 1 uses electrostatic suspension forces to measure a change in acceleration of a test mass due to a displaced source mass. Experiment 2 measures a change in relative acceleration between two test masses due to a slowly varying fuel tank mass. Experiment 1 gave a value of G=6.71±0.42(×10-11)¿¿m3¿s-2¿kg-1 and experiment 2 gave 6.15±0.35(×10-11)¿¿m3¿s-2¿kg-1, both consistent with each other to 1s and with the CODATA 2014 recommended value of 6.67408±0.00031(×10-11)¿¿m3¿s-2¿kg-1 to 2s. We outline several ideas to improve the results for a future experiment, and we suggest that a measurement in space would isolate many terrestrial issues that could be responsible for the inconsistencies between recent measurements.Peer ReviewedPostprint (published version

    Temperature stability in the sub-milliHertz band with LISA Pathfinder

    Get PDF
    This article has been accepted for publication in "Monthly notices of the royal astronomical society" published by Oxford University Press.LISA Pathfinder (LPF) was a technology pioneering mission designed to test key technologies required for gravitational wave detection in space. In the low frequency regime (milliHertz and below), where space-based gravitational wave observatories will operate, temperature fluctuations play a crucial role since they can couple into the interferometric measurement and the test masses’ free-fall accuracy in many ways. A dedicated temperature measurement subsystem, with noise levels in 10¿µK¿Hz-1/2 down to 1¿mHz was part of the diagnostics unit onboard LPF. In this paper we report on the temperature measurements throughout mission operations, characterize the thermal environment, estimate transfer functions between different locations, and report temperature stability (and its time evolution) at frequencies as low as 10¿µHz, where typically values around 1¿K¿Hz-1/2 were measured.Peer ReviewedPreprin

    3d absorption-spectra of Sr I through Sr IV

    Get PDF
    The extreme ultraviolet photoabsorption spectra of neutral to three-times-ionized strontium have been recorded in a comprehensive series of experiments with the dual laser-produced plasma technique. Striking differences were found in the spectra, which can be attributed to the transfer of oscillator strength from 3d→np to 3d→nf transitions at Sr2+ due to nf wave-function contraction. In Sr and Sr+, 3d→5p transitions dominate; in Sr2+, 3d→nf transitions are most intense, while in Sr3+ the 4p subshell opens and 3d→4p transitions are the strongest features. Partial cross sections for 3d→ɛf and 3d→ɛp photoionization were calculated and compared with experiment

    LISA Pathfinder platform stability and drag-free performance

    Get PDF
    The science operations of the LISA Pathfinder mission have demonstrated the feasibility of sub-femto-g free fall of macroscopic test masses necessary to build a gravitational wave observatory in space such as LISA. While the main focus of interest, i.e., the optical axis or the x-axis, has been extensively studied, it is also of great importance to evaluate the stability of the spacecraft with respect to all the other degrees of freedom (d.o.f.). The current paper is dedicated to such a study: the exhaustive and quantitative evaluation of the imperfections and dynamical effects that impact the stability with respect to its local geodesic. A model of the complete closed-loop system provides a comprehensive understanding of each component of the in-loop coordinates spectral density. As will be presented, this model gives very good agreement with LISA Pathfinder flight data. It allows one to identify the noise source at the origin and the physical phenomena underlying the couplings. From this, the stability performance of the spacecraft with respect to its geodesic is extracted as a function of frequency. Close to 1 mHz, the stability of the spacecraft on the XSC, YSC and ZSC d.o.f. is shown to be of the order of 5.0×10-15¿¿m¿s-2¿Hz-1/2 for X, 6.0×10-14¿¿m¿s-2¿Hz-1/2 for Y, and 4.0×10-14¿¿m¿s-2¿Hz-1/2 for Z. For the angular d.o.f., the values are of the order of 3×10-12¿¿rad¿s-2¿¿Hz-1/2 for TSC, 5×10-13¿¿rad¿s-2¿¿Hz-1/2 for HSC, and 3×10-13¿¿rad¿s-2¿¿Hz-1/2 for FSC. Below 1 mHz, however, the stability performances are worsened significantly by the effect of the star tracker noise on the closed-loop system. It is worth noting that LISA is expected to be spared from such concerns, as differential wave-front sensing, an attitude sensor system of much higher precision, will be utilized for attitude control.Peer ReviewedPostprint (author's final draft

    LISA pathfinder performance confirmed in an open-loop configuration: results from the free-fall actuation mode

    Get PDF
    We report on the results of the LISA Pathfinder (LPF) free-fall mode experiment, in which the control force needed to compensate the quasistatic differential force acting on two test masses is applied intermittently as a series of "impulse" forces lasting a few seconds and separated by roughly 350 s periods of true free fall. This represents an alternative to the normal LPF mode of operation in which this balancing force is applied continuously, with the advantage that the acceleration noise during free fall is measured in the absence of the actuation force, thus eliminating associated noise and force calibration errors. The differential acceleration noise measurement presented here with the free-fall mode agrees with noise measured with the continuous actuation scheme, representing an important and independent confirmation of the LPF result. An additional measurement with larger actuation forces also shows that the technique can be used to eliminate actuation noise when this is a dominant factor.Peer ReviewedPostprint (published version

    Sequential effects in two-choice reaction time tasks: decomposition and synthesis of mechanisms

    Get PDF
    Performance on serial tasks is influenced by first- and higher-order sequential effects, respectively due to the immediately previous and earlier trials. As response-to-stimulus interval (RSI) increases, the pattern of reaction times transits from a benefit-only mode, traditionally ascribed to automatic facilitation (AF), to a cost-benefit mode, due to strategic expectancy (SE). To illuminate the sources of such effects, we develop a connectionist network of two mutually-inhibiting neural decision units subject to feedback from previous trials. A study of separate biasing mechanisms shows that residual decision unit activity can lead only to first-order AF, but higher-order AF can result from strategic priming mediated by conflict-monitoring, which we instantiate in two distinct versions. A further mechanism mediates expectation-related biases that grow during RSI toward saturation levels determined by weighted repetition (or alternation) sequence lengths. Equipped with these mechanisms, the network, consistent with known neurophysiology, accounts for several sets of behavioral data over a wide range of RSIs. The results also suggest that practice speeds up all the mechanisms rather than adjusting their relative strengths

    Prototype finline-coupled TES bolometers for CLOVER

    Full text link
    CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz. The 97-GHz telescope has 160 feedhorns in its focal plane while the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a hexagonal array and feed a polarimeter which uses finline-coupled TES bolometers as detectors. To detect the two polarizations the 97-GHz telescope has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each. To achieve the target NEPs (1.5, 2.5, and 4.5x10^-17 W/rtHz) the detectors are cooled to 100 mK for the 97 and 150-GHz polarimeters and 230 mK for the 220-GHz polarimeter. Each detector is fabricated as a single chip to ensure a 100% operational focal plane. The detectors are contained in linear modules made of copper which form split-block waveguides. The detector modules contain 16 or 20 detectors each for compatibility with the hexagonal arrays of horns in the telescopes' focal planes. Each detector module contains a time-division SQUID multiplexer to read out the detectors. Further amplification of the multiplexed signals is provided by SQUID series arrays. The first prototype detectors for CLOVER operate with a bath temperature of 230 mK and are used to validate the detector design as well as the polarimeter technology. We describe the design of the CLOVER detectors, detector blocks, and readout, and present preliminary measurements of the prototype detectors performance.Comment: 4 pages, 6 figures; to appear in the Proceedings of the 17th International Symposium on Space Terahertz Technology, held 10-12 May 2006 in Pari

    OXBench:a benchmark for evaluation of protein multiple sequence alignment accuracy

    Get PDF
    BACKGROUND: The alignment of two or more protein sequences provides a powerful guide in the prediction of the protein structure and in identifying key functional residues, however, the utility of any prediction is completely dependent on the accuracy of the alignment. In this paper we describe a suite of reference alignments derived from the comparison of protein three-dimensional structures together with evaluation measures and software that allow automatically generated alignments to be benchmarked. We test the OXBench benchmark suite on alignments generated by the AMPS multiple alignment method, then apply the suite to compare eight different multiple alignment algorithms. The benchmark shows the current state-of-the art for alignment accuracy and provides a baseline against which new alignment algorithms may be judged.RESULTS: The simple hierarchical multiple alignment algorithm, AMPS, performed as well as or better than more modern methods such as CLUSTALW once the PAM250 pair-score matrix was replaced by a BLOSUM series matrix. AMPS gave an accuracy in Structurally Conserved Regions (SCRs) of 89.9% over a set of 672 alignments. The T-COFFEE method on a data set of families with &lt;8 sequences gave 91.4% accuracy, significantly better than CLUSTALW (88.9%) and all other methods considered here. The complete suite is available from http://www.compbio.dundee.ac.uk.CONCLUSIONS: The OXBench suite of reference alignments, evaluation software and results database provide a convenient method to assess progress in sequence alignment techniques. Evaluation measures that were dependent on comparison to a reference alignment were found to give good discrimination between methods. The STAMP Sc Score which is independent of a reference alignment also gave good discrimination. Application of OXBench in this paper shows that with the exception of T-COFFEE, the majority of the improvement in alignment accuracy seen since 1985 stems from improved pair-score matrices rather than algorithmic refinements. The maximum theoretical alignment accuracy obtained by pooling results over all methods was 94.5% with 52.5% accuracy for alignments in the 0-10 percentage identity range. This suggests that further improvements in accuracy will be possible in the future.</p
    corecore