53 research outputs found

    Assessment of the kidneys: magnetic resonance angiography, perfusion and diffusion

    Get PDF
    Renal magnetic resonance (MR) imaging has undergone major improvements in the past several years. This review focuses on the technical basics and clinical applications of MR angiography (MRA) with the goal of enabling readers to acquire high-resolution, high quality renal artery MRA. The current role of contrast agents and their safe use in patients with renal impairment is discussed. In addition, an overview of promising techniques on the horizon for renal MR is provided. The clinical value and specific applications of renal MR are critically discussed

    Women in radiology: gender diversity is not a metric-it is a tool for excellence.

    Get PDF
    Women in Focus: Be Inspired was a unique programme held at the 2019 European Congress of Radiology that was structured to address a range of topics related to gender and healthcare, including leadership, mentoring and the generational progression of women in medicine. In most countries, women constitute substantially fewer than half of radiologists in academia or private practice despite frequently accounting for at least half of medical school enrolees. Furthermore, the proportion of women decreases at higher academic ranks and levels of leadership, a phenomenon which has been referred to as a "leaky pipeline". Gender diversity in the radiologic workplace, including in academic and leadership positions, is important for the present and future success of the field. It is a tool for excellence that helps to optimize patient care and research; moreover, it is essential to overcome the current shortage of radiologists. This article reviews the current state of gender diversity in academic and leadership positions in radiology internationally and explores a wide range of potential reasons for gender disparities, including the lack of role models and mentorship, unconscious bias and generational changes in attitudes about the desirability of leadership positions. Strategies for both individuals and institutions to proactively increase the representation of women in academic and leadership positions are suggested. KEY POINTS: • Gender-diverse teams perform better. Thus, gender diversity throughout the radiologic workplace, including in leadership positions, is important for the current and future success of the field. • Though women now make up roughly half of medical students, they remain underrepresented among radiology trainees, faculty and leaders. • Factors leading to the gender gap in academia and leadership positions in Radiology include a lack of role models and mentors, unconscious biases, other societal barriers and generational changes

    Detection of local recurrence with 3-tesla MRI after radical prostatectomy: A useful method for radiation treatment planning?

    Get PDF
    Background/Aim: Salvage radiotherapy improves biochemical control in patients with recurrence of prostate cancer after prostatectomy. Radiotherapy target volumes of the prostatic fossa are based on empirical data and differ between different guidelines. Localization of recurrence with multiparametric magnetic resonance imaging (MRI) might be a feasible approach to localize recurrent lesions. Patients and Methods: Twenty-one patients with biochemical recurrence after radical prostatectomy were included (median prostate-specific antigen (PSA) =0.17 ng/ml). Multi-parametric MRI was performed using a 3-T MR system. Results: Lesions were detected in seven patients with a median PSA of 0.86 ng/ml (minimum= 0.31 ng/ml). Patients without detectable recurrence had a median PSA of 0.12 ng/ml. All patients with detectable lesions responded to radiotherapy. Eleven out of 14 patients without detectable recurrence also responded. Plasma flow in suspicious lesions was correlated with PSA level. Conclusion: Detection of recurrence at the prostatic fossa with our approach was possible in a minority of patients with a low PSA level. Clinical relevance of plasma flow in suspicious lesions should be further investigated

    Women in radiology: gender diversity is not a metric—it is a tool for excellence

    Get PDF
    Abstract: Women in Focus: Be Inspired was a unique programme held at the 2019 European Congress of Radiology that was structured to address a range of topics related to gender and healthcare, including leadership, mentoring and the generational progression of women in medicine. In most countries, women constitute substantially fewer than half of radiologists in academia or private practice despite frequently accounting for at least half of medical school enrolees. Furthermore, the proportion of women decreases at higher academic ranks and levels of leadership, a phenomenon which has been referred to as a “leaky pipeline”. Gender diversity in the radiologic workplace, including in academic and leadership positions, is important for the present and future success of the field. It is a tool for excellence that helps to optimize patient care and research; moreover, it is essential to overcome the current shortage of radiologists. This article reviews the current state of gender diversity in academic and leadership positions in radiology internationally and explores a wide range of potential reasons for gender disparities, including the lack of role models and mentorship, unconscious bias and generational changes in attitudes about the desirability of leadership positions. Strategies for both individuals and institutions to proactively increase the representation of women in academic and leadership positions are suggested. Key Points: • Gender-diverse teams perform better. Thus, gender diversity throughout the radiologic workplace, including in leadership positions, is important for the current and future success of the field. • Though women now make up roughly half of medical students, they remain underrepresented among radiology trainees, faculty and leaders. • Factors leading to the gender gap in academia and leadership positions in Radiology include a lack of role models and mentors, unconscious biases, other societal barriers and generational changes

    Comparison of Dynamic and Liver-Specific Gadoxetic Acid Contrast-Enhanced MRI versus Apparent Diffusion Coefficients

    Get PDF
    Hepatic lesions often present diagnostic connundrums with conventional MR techniques. Hepatobiliary phase contrast-enhanced imaging with gadoxetic acid can aid in the characterization of such lesions. However, quantitative measures describing late-phase enhancement must be assessed relative to their accuracy of hepatic lesion classification.To compare quantitative parameters in gadoxetic acid contrast-enhanced dynamic and hepatobiliary phase imaging versus apparent diffusion coefficients in hepatic lesion characterization.57 patients with focal hepatic lesions on gadoxetic acid MR were included. Lesion enhancement at standard post-contrast time points and in the hepatobiliary phase (HB; 15 and 25 minutes post-contrast) was assessed via calculation of contrast (CR) and enhancement ratios (ER). Apparent diffusion coefficient (ADC) values were also obtained. Values for these parameters were compared among lesions and ROC analyses performed.HB enhancement was greatest with FNH and adenomas. HB ER parameters but not HB CR could distinguish HCC from benign entities (0.9 ER ROC AUC versus 0.5 CR ROC AUC). There was no statistically significant difference found between the 15 and 25 minutes HB time points in detection of any lesion (p>0.4). ADC values were statistically significantly higher with hemangiomas (p<0.05) without greater accuracy in lesion detection relative to HB phase parameters.Hepatobiliary phase gadoxetic acid contrast-enhanced MR characterizes focal hepatic lesions more accurately than ADC and conventional dynamic post-contrast time point enhancement parameters. ER values are generally superior to CR. No discernible benefit of 25 minute versus 15 minute delayed imaging is demonstrated

    In Vitro Evaluation of Acrylic Adhesives in Lymphatic Fluids-Influence of Glue Type and Procedural Parameters

    No full text
    To evaluate the embolic properties of different acrylic adhesive/iodized oil mixtures for lymphatic interventions. Polymerization of histoacryl (HA) (Bayer Healthcare) and glubran 2 (GL) (GEM) mixed with iodized oil (ratios 1:0–1:7) were investigated in lymphatic fluids with low and high triglyceride (low TG & high TG) contents. Static polymerization time and dynamic polymerization experiments with different volumes of glucose flush (1, 2 and 5 mL) were performed to simulate thoracic duct embolization. For both glues, static polymerization times were longer when the iodized oil content was increased and when performed in high TG lymphatic fluid. In the dynamic experiments, the prolongation of polymerization due to the oil content and TG levels was less pronounced for both glue types. Increased lymphatic flow rates decreased embolization times for low glue/oil ratios while preventing embolization for high glue/oil ratios. Higher glucose flush volumes increased occlusion times. Polymerization times of acrylic glue in a lymphatic fluid are prolonged by increasing the iodized oil concentration and triglyceride concentration as well as by using larger volumes of glucose flush. Increased lymphatic flow rates decrease embolization times for low glue/oil ratios and may prevent embolization for high glue/oil ratios

    Comparison of perfusion models for quantitative T1 weighted DCE-MRI of rectal cancer [Dataset]

    No full text
    Twenty-six patients with newly diagnosed rectal carcinoma underwent 3T MRI of the pelvis including a T1 weighted dynamic contrast enhanced (DCE) protocol before treatment. For eighteen patients, mean values for Plasma Flow (PF), Plasma Volume (PV) and Mean Transit Time (MTT) were obtained for three perfusion models

    Zoomed EPI-DWI of the pancreas using two-dimensional spatially-selective radiofrequency excitation pulses.

    No full text
    BACKGROUND: Implementation of DWI in the abdomen is challenging due to artifacts, particularly those arising from differences in tissue susceptibility. Two-dimensional, spatially-selective radiofrequency (RF) excitation pulses for single-shot echo-planar imaging (EPI) combined with a reduction in the FOV in the phase-encoding direction (i.e. zooming) leads to a decreased number of k-space acquisition lines, significantly shortening the EPI echo train and potentially susceptibility artifacts. PURPOSE: To assess the feasibility and image quality of a zoomed diffusion-weighted EPI (z-EPI) sequence in MR imaging of the pancreas. The approach is compared to conventional single-shot EPI (c-EPI). MATERIAL AND METHODS: 23 patients who had undergone an MRI study of the abdomen were included in this retrospective study. Examinations were performed on a 3T whole-body MR system (Magnetom Skyra, Siemens) equipped with a two-channel fully dynamic parallel transmit array (TimTX TrueShape, Siemens). The acquired sequences consisted of a conventional EPI DWI of the abdomen and a zoomed EPI DWI of the pancreas. For z-EPI, the standard sinc excitation was replaced with a two-dimensional spatially-selective RF pulse using an echo-planar transmit trajectory. Images were evaluated with regard to image blur, respiratory motion artifacts, diagnostic confidence, delineation of the pancreas, and overall scan preference. Additionally ADC values of the pancreatic head, body, and tail were calculated and compared between sequences. RESULTS: The pancreas was better delineated in every case (23/23) with z-EPI versus c-EPI. In every case (23/23), both readers preferred z-EPI overall to c-EPI. With z-EPI there was statistically significantly less image blur (p<0.0001) and respiratory motion artifact compared to c-EPI (p<0.0001). Diagnostic confidence was statistically significantly better with z-EPI (p<0.0001). No statistically significant differences in calculated ADC values were observed between the two sequences. CONCLUSION: Zoomed diffusion-weighted EPI leads to substantial image quality improvements with reduction of susceptibility artifacts in pancreatic DWI
    • …
    corecore