110 research outputs found

    Future demand for primary hip and knee arthroplasty in Scotland

    Get PDF
    ACKNOWLEDGEMENTS The authors are grateful to the Scottish Arthroplasty Project for the data utilised in this manuscript. No funding was received for this study.Peer reviewedPublisher PD

    Novel use of Steinman pin in removal of broken interlocking screws

    Get PDF
    Broken screws after interlocking nailing of long bones are commonly seen in Orthopaedic practice. Removal of such screws can be difficult particularly the distal part which is often held within the bone. We describe a simple technique of using Steinman pin to aid removal of broken screws in a case of non-union fracture tibia with broken interlocking nail and screws. Steinman pin being easily available and the reproducible technique make it a useful aid for removal of broken interlocking screws

    A systematic review of tranexamic acid in hip fracture surgery

    Get PDF
    Aim: To systematically examine and quantify the efficacy and safety of Tranexamic acid in hip fracture surgery.  Methods: A systematic literature search was conducted using Medline, EMBASE, AMED, CiNAHL, and the Cochrane Central Registry of Controlled Trials. Two assessors independently screened search outputs for potentially relevant articles which met the eligibility criteria. The primary outcome measure was requirement of post-operative blood transfusion. Risk of bias assessment was performed using the Cochrane Collaboration’s risk of bias tool for RCT’s and the ROBINS-I tool for observational studies. Meta-analysis was performed to estimate risk ratio (RR), risk difference (RD) and mean difference (MD) values for dichotomous and continuous data outcomes respectively. The interpretation of each outcome was made using the GRADE approach.  Results: Of 102 studies identified, seven met the inclusion criteria including a total of 770 participants (TXA: 341; Control: 429). On meta-analysis, intra-venous TXA resulted in a 46% risk reduction in blood transfusion requirement compared to a placebo/control group (RR:0.54; 95% CI: 0.35 to 0.85; I2: 78%; Inconsistency (Chi2) p=<0.0001; N=750). There was also a significantly higher post-operative haemoglobin for TXA versus placebo/control (MD:0.81; 95% CI: 0.45 to 1.18; I2: 46%; Inconsistency (Chi2) p=0.10; N=638). There was no increased risk of thromboembolic events (RD:0.01; 95% CI: -0.03, 0.05; I2: 68%; Inconsistency (Chi2) p=0.007, N=683).  Conclusion: There is moderate quality evidence that TXA reduces blood transfusion in hip fracture surgery, with low quality evidence suggesting no increased risk of thrombotic events. These findings are consistent with TXA use in other orthopaedic procedures

    A New Method for Investigating Osteoarthritis using Fast Field Cycling Nuclear Magnetic Resonance

    Get PDF
    ACKNOWLEDGEMENTS We acknowledge ARUK (Versus Arthritis) for funding this study (grant number 19869) and the NHS Grampian Biorepository for the access to cartilage samples. BWCK received a Foulkes Foundation Fellowship. This project has also received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 668119 (project “IDentIFY”) and NHS Grampian endowments. This work received support from the EURELAX COST Action CA15209, supported by COST (European Cooperation in Science and Technology).Peer reviewedPublisher PD

    A longitudinal study of muscle rehabilitation in the lower leg after cast removal using Magnetic Resonance Imaging and strength assessment

    Get PDF
    Acknowledgements We thank the A&E nurses and plaster technicians for identifying suitable patients, the MRI radiographers for performing the scanning, Dr Scott Semple for invaluable help in some of the pilot studies and Mr E. C. Stevenson for constructing the footrest used in the scanner. We are very grateful to the dedicated patients themselves who gave considerable amounts of time to come in for scanning, exercise and assessment during the course of this study.Peer reviewedPublisher PD

    Adult onset global loss of the fto gene alters body composition and metabolism in the mouse.

    Get PDF
    The strongest BMI-associated GWAS locus in humans is the FTO gene. Rodent studies demonstrate a role for FTO in energy homeostasis and body composition. The phenotypes observed in loss of expression studies are complex with perinatal lethality, stunted growth from weaning, and significant alterations in body composition. Thus understanding how and where Fto regulates food intake, energy expenditure, and body composition is a challenge. To address this we generated a series of mice with distinct temporal and spatial loss of Fto expression. Global germline loss of Fto resulted in high perinatal lethality and a reduction in body length, fat mass, and lean mass. When ratio corrected for lean mass, mice had a significant increase in energy expenditure, but more appropriate multiple linear regression normalisation showed no difference in energy expenditure. Global deletion of Fto after the in utero and perinatal period, at 6 weeks of age, removed the high lethality of germline loss. However, there was a reduction in weight by 9 weeks, primarily as loss of lean mass. Over the subsequent 10 weeks, weight converged, driven by an increase in fat mass. There was a switch to a lower RER with no overall change in food intake or energy expenditure. To test if the phenotype can be explained by loss of Fto in the mediobasal hypothalamus, we sterotactically injected adeno-associated viral vectors encoding Cre recombinase to cause regional deletion. We observed a small reduction in food intake and weight gain with no effect on energy expenditure or body composition. Thus, although hypothalamic Fto can impact feeding, the effect of loss of Fto on body composition is brought about by its actions at sites elsewhere. Our data suggest that Fto may have a critical role in the control of lean mass, independent of its effect on food intake

    Modeling the excitation of graphene plasmons in periodic grids of graphene ribbons: an analytical approach

    Get PDF
    We study electromagnetic scattering and subsequent plasmonic excitations in periodic grids of graphene ribbons. To address this problem, we develop an analytical method to describe the plasmon-assisted absorption of electromagnetic radiation by a periodic structure of graphene ribbons forming a diffraction grating for THz and mid-IR light. The major advantage of this method lies in its ability to accurately describe the excitation of graphene surface plasmons (GSPs) in one-dimensional (1D) graphene gratings without the use of both time-consuming, and computationally-demanding full-wave numerical simulations. We thus provide analytical expressions for the reflectance, transmittance and plasmon-enhanced absorbance spectra, which can be readily evaluated in any personal laptop with little-to-none programming. We also introduce a semi-analytical method to benchmark our previous results and further compare the theoretical data with spectra taken from experiments, to which we observe a very good agreement. These theoretical tools may therefore be applied to design new experiments and cutting-edge nanophotonic devices based on graphene plasmonics.The authors thank N. Asger Mortensen for insightful and valuable comments. PADG acknowledges financial support from Fundação para a Ciência e a Tecnologia (Portugal) from grant No. PD/BI/114376/2016. NMRP and YVB acknowledge financial support from the European Commission through the project “GrapheneDriven Revolutions in ICT and Beyond” (Ref. No. 696656). This work was partially supported by the Portuguese Foundation for Science and Technology (FCT) in the framework of the Strategic Financing UID/FIS/04650/2013. The Center for Nanostructured Graphene is sponsored by the Danish National Research Foundation, Project DNRF103

    Phonon-assisted radiofrequency absorption by gold nanoparticles resulting in hyperthermia

    Full text link
    It is suggested that in gold nanoparticles (GNPs) of about 5 nm sizes used in the radiofrequency (RF) hyperthermia, an absorption of the RF photon by the Fermi electron occurs with involvement of the longitudinal acoustic vibrational mode (LAVM), the dominating one in the distribution of vibrational density of states (VDOS). This physical mechanism helps to explain two observed phenomena: the size dependence of the heating rate (HR) in GNPs and reduced heat production in aggregated GNPs. The argumentation proceeds within the one-electron approximation, taking into account the discretenesses of energies and momenta of both electrons and LAVMs. The heating of GNPs is thought to consist of two consecutive processes: first, the Fermi electron absorbs simultaneously the RF photon and the LAVM available in the GNP; hereafter the excited electron gets relaxed within the GNP's boundary, exciting a LAVM with the energy higher than that of the previously absorbed LAVM. GNPs containing the Ta and/or Fe impurities are proposed for the RF hyperthermia as promising heaters with enhanced HRs, and GNPs with rare-earth impurity atoms are also brought into consideration. It is shown why the maximum HR values should be expected in GNPs with about 5-7 nm size.Comment: proceedings at the NATO Advanced Research workshop FANEM-2015 (Minsk, May 25-27, 2015). To be published in the final form in: "Fundamental and Applied NanoElectroMagnetics" (Springer Science + Business Media B.V.
    corecore