12 research outputs found

    Measuring mechanical cues for modeling the stromal matrix in 3D cell cultures

    No full text
    Publisher Copyright: © 2024 The Royal Society of Chemistry.A breast-cancer tumor develops within a stroma, a tissue where a complex extracellular matrix surrounds cells, mediating the cancer progression through biomechanical and -chemical cues. Current materials partially mimic the stromal matrix in 3D cell cultures but methods for measuring the mechanical properties of the matrix at cell-relevant-length scales and stromal-stiffness levels are lacking. Here, to address this gap, we developed a characterization approach that employs probe-based microrheometry and Bayesian modeling to quantify length-scale-dependent mechanics and mechanical heterogeneity as in the stromal matrix. We examined the interpenetrating network (IPN) composed of alginate scaffolds (for adjusting mechanics) and type-1 collagen (a stromal-matrix constituent). We analyzed viscoelasticity: absolute-shear moduli (stiffness/elasticity) and phase angles (viscous and elastic characteristics). We determined the relationship between microrheometry and rheometry information. Microrheometry reveals lower stiffness at cell-relevant scales, compared to macroscale rheometry, with dependency on the length scale (10 to 100 μm). These data show increasing IPN stiffness with crosslinking until saturation (≃15 mM of Ca2+). Furthermore, we report that IPN stiffness can be adjusted by modulating collagen concentration and interconnectivity (by polymerization temperature). The IPNs are heterogeneous structurally (in SEM) and mechanically. Interestingly, increased alginate crosslinking changes IPN heterogeneity in stiffness but not in phase angle, until the saturation. In contrast, such changes are undetectable in alginate scaffolds. Our nonlinear viscoelasticity analysis at tumor-cell-exerted strains shows that only the softer IPNs stiffen with strain, like the stromal-collagen constituent. In summary, our approach can quantify the stromal-matrix-related viscoelasticity and is likely applicable to other materials in 3D culture.Peer reviewe

    Association between self-reported hypertension onset age and electrocardiographic left ventricular hypertrophy

    Get PDF
    Published: 19 October 202

    Magnetic microrheometry of tumor-relevant stiffness levels and probabilistic quantification of viscoelasticity differences inside 3D cell culture matrices.

    No full text
    The progression of breast cancer involves cancer-cell invasions of extracellular matrices. To investigate the progression, 3D cell cultures are widely used along with different types of matrices. Currently, the matrices are often characterized using parallel-plate rheometry for matrix viscoelasticity, or liquid-like viscous and stiffness-related elastic characteristics. The characterization reveals averaged information and sample-to-sample variation, yet, it neglects internal heterogeneity within matrices, experienced by cancer cells in 3D culture. Techniques using optical tweezers and magnetic microrheometry have measured heterogeneity in viscoelasticity in 3D culture. However, there is a lack of probabilistic heterogeneity quantification and cell-size-relevant, microscale-viscoelasticity measurements at breast-tumor tissue stiffness up to ≃10 kPa in Young's modulus. Here, we have advanced methods, for the purpose, which use a magnetic microrheometer that applies forces on magnetic spheres within matrices, and detects the spheres displacements. We present probabilistic heterogeneity quantification using microscale-viscoelasticity measurements in 3D culture matrices at breast-tumor-relevant stiffness levels. Bayesian multilevel modeling was employed to distinguish heterogeneity in viscoelasticity from the effects of experimental design and measurement errors. We report about the heterogeneity of breast-tumor-relevant agarose, GrowDex, GrowDex-collagen and fibrin matrices. The degree of heterogeneity differs for stiffness, and phase angle (i.e. ratio between viscous and elastic characteristics). Concerning stiffness, agarose and GrowDex show the lowest and highest heterogeneity, respectively. Concerning phase angle, fibrin and GrowDex-collagen present the lowest and the highest heterogeneity, respectively. While this heterogeneity information involves softer matrices, probed by ≃30 μm magnetic spheres, we employ larger ≃100 μm spheres to increase magnetic forces and acquire a sufficient displacement signal-to-noise ratio in stiffer matrices. Thus, we show pointwise microscale viscoelasticity measurements within agarose matrices up to Young's moduli of 10 kPa. These results establish methods that combine magnetic microrheometry and Bayesian multilevel modeling for enhanced heterogeneity analysis within 3D culture matrices

    Incidence rates, correlates, and prognosis of electrocardiographic P-wave abnormalities - a nationwide population-based study

    Get PDF
    Background: Scant data exist on incidence rates, correlates, and prognosis of electrocardiographic P-wave abnormalities in the general population. Methods: We recorded ECG and measured conventional cardiovascular risk factors in 5667 Finns who were followed up for incident atrial fibrillation (AF). We obtained repeat ECGs from 3089 individuals I I years later. Results: The incidence rates of prolonged P-wave duration, abnormal P terminal force (PTF), left P-wave axis deviation, and right P-wave axis deviation were 16.0%, 7.4%, 3.4%, and 2.2%, respectively. Older age and higher BMI were associated with incident prolonged P-wave duration and abnormal PTF (P Conclusions: Modifiable risk factors associate with P-wave abnormalities that are common and may represent intermediate steps of atrial cardiomyopathy on a pathway leading to AF. (C) 2017 Elsevier Inc. All rights reserved.Peer reviewe

    Characterizing Aptamers with Reconfigurable Chiral Plasmonic Assemblies

    No full text
    | openaire: EC/H2020/713645/EU//BioMEPAptamers have emerged as versatile affinity ligands and as promising alternatives to protein antibodies. However, the inconsistency in the reported affinities and specificities of aptamers has greatly hindered the development of aptamer-based applications. Herein, we present a strategy to characterize aptamers by using DNA origami-based chiral plasmonic assemblies as reporters and establishing a competitive hybridization reaction-based thermodynamic model. We demonstrate the characterization of several DNA aptamers, including aptamers for small molecules and macromolecules, as well as aptamers with high and low affinities. The presented characterization scheme can be readily adapted to a wide selection of aptamers. We anticipate that our approach will advance the development of aptamer-based applications by enabling reliable and reproducible characterization of aptamers.Peer reviewe

    Light-Responsive Dynamic DNA-Origami-Based Plasmonic Assemblies

    No full text
    https://doi.org/10.1002/anie.202014963DNA nanotechnology offers a versatile toolbox for precise spatial and temporal manipulation of matter on the nanoscale. However, rendering DNA-based systems responsive to light has remained challenging. Herein, we describe the remote manipulation of native (non-photoresponsive) chiral plasmonic molecules (CPMs) using light. Our strategy is based on the use of a photoresponsive medium comprising a merocyanine-based photoacid. Upon exposure to visible light, the medium decreases its pH, inducing the formation of DNA triplex links, leading to a spatial reconfiguration of the CPMs. The process can be reversed simply by turning the light off and it can be repeated for multiple cycles. The degree of the overall chirality change in an ensemble of CPMs depends on the CPM fraction undergoing reconfiguration, which, remarkably, depends on and can be tuned by the intensity of incident light. Such a dynamic, remotely controlled system could aid in further advancing DNA-based devices and nanomaterials.Peer reviewe
    corecore