25 research outputs found

    Measurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler: time for a reassessment?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Echocardiographic measurements of left ventricular (LV) myocardial displacement may produce different results depending on the choice of employed modality and subjective adjustments during data acquisition and analysis.</p> <p>Methods</p> <p>In this study, left ventricular longitudinal systolic displacement was quantified in 57 patients (31 women and 26 men, 50 ± 16 years) using colour (colour TD) and spectral tissue Doppler (spectral TD) before and after temporal filtering (30 to 70 milliseconds in 20-millisecond steps) and changed offline gain saturation (0%, 50% and 100%), respectively. The results were compared with those obtained with anatomic M-mode.</p> <p>Results</p> <p>Whereas only minor differences occurred between the results of colour TD and anatomic M-mode measurements, spectral TD significantly overestimated the results obtained with both these methods. However, the limits of agreement between the results produced by all three studied methods were not clinically acceptable in any of the cases. The spectral TD displacement values increased along with increasing offline gain saturation whereas the effect of temporal filtering on colour Doppler measurements was insignificant.</p> <p>Conclusion</p> <p>Measurements of LV myocardial longitudinal displacement employing spectral TD, colour TD or anatomic M-mode produce different results, thus discouraging interchangeable use of these modalities. Whereas the results of spectral TD measurements can be significantly altered by changing offline gain setting, the effect of temporal filtering on colour TD measurements is insignificant, a fact that increases clinical practicality of the latter method.</p

    Visually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Visual assessment of left ventricular ejection fraction (LVEF) is often used in clinical routine despite general recommendations to use quantitative biplane Simpsons (BPS) measurements. Even thou quantitative methods are well validated and from many reasons preferable, the feasibility of visual assessment (eyeballing) is superior. There is to date only sparse data comparing visual EF assessment in comparison to quantitative methods available. The aim of this study was to compare visual EF assessment by two-dimensional echocardiography (2DE) and triplane echocardiography (TPE) using quantitative real-time three-dimensional echocardiography (RT3DE) as the reference method.</p> <p>Methods</p> <p>Thirty patients were enrolled in the study. Eyeballing EF was assessed using apical 4-and 2 chamber views and TP mode by two experienced readers blinded to all clinical data. The measurements were compared to quantitative RT3DE.</p> <p>Results</p> <p>There were an excellent correlation between eyeballing EF by 2D and TP vs 3DE (r = 0.91 and 0.95 respectively) without any significant bias (-0.5 ± 3.7% and -0.2 ± 2.9% respectively). Intraobserver variability was 3.8% for eyeballing 2DE, 3.2% for eyeballing TP and 2.3% for quantitative 3D-EF. Interobserver variability was 7.5% for eyeballing 2D and 8.4% for eyeballing TP.</p> <p>Conclusion</p> <p>Visual estimation of LVEF both using 2D and TP by an experienced reader correlates well with quantitative EF determined by RT3DE. There is an apparent trend towards a smaller variability using TP in comparison to 2D, this was however not statistically significant.</p

    Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation

    Get PDF
    BACKGROUND: Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter- and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF. METHODS: A total of 78 patients were included in this study. Fifty-five with sinus rhythm (group A) and 23 having AF (group B). 4B and SB 3DE was performed in all patients. LV volumes and EF was determined by these two modalities and inter- and intraobserver variability was analyzed. RESULTS: SB modality showed significantly lower inter- and intraobserver variability in group B in comparison to 4B when measuring LV volumes and EF, except for end-systolic volume (ESV) in intraobserver analysis. There were significant differences when calculating the LV volumes (p<0.001) and EF (p<0.05) with SB in comparison to 4B in group B. CONCLUSION: Single-beat three-dimensional full volume acquisition seems to be superior to four-beat ECG-gated acquisition in measuring left ventricular volumes and ejection fraction in patients having atrial fibrillation. The variability is significantly lower both for ejection fraction and left ventricular volumes

    Determinants and prognostic implications of the negative diastolic pulmonary pressure gradient in patients with pulmonary hypertension due to left heart disease

    Get PDF
    AIMS: The diastolic pulmonary pressure gradient (DPG) has recently been introduced as a specific marker of combined pre-capillary pulmonary hypertension (Cpc-PH) in left heart disease (LHD). However, its diagnostic and prognostic superiority compared with traditional haemodynamic indices has been challenged lately. Current recommendations explicitly denote that in the normal heart, DPG values are greater than zero, with DPG >/=7 mmHg indicating Cpc-PH. However, clinicians are perplexed by the frequent observation of DPG 0.05). Patients with large V-waves had negative and lower DPG than those without augmented V-waves (P 0.05). Positive, but normal DPG (0-6 mmHg) carried a worse 2-year prognosis for death and/or heart transplantation than DPGNEG (hazard ratio 2.97; P < 0.05). CONCLUSION: Our results advocate against DPGNEG constituting a measurement error. We propose that DPGNEG can partially be ascribed to large V-waves and carries a better prognosis than DPG within the normal positive range

    Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation

    No full text
    Abstract Background Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter- and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF. Methods A total of 78 patients were included in this study. Fifty-five with sinus rhythm (group A) and 23 having AF (group B). 4B and SB 3DE was performed in all patients. LV volumes and EF was determined by these two modalities and inter- and intraobserver variability was analyzed. Results SB modality showed significantly lower inter- and intraobserver variability in group B in comparison to 4B when measuring LV volumes and EF, except for end-systolic volume (ESV) in intraobserver analysis. There were significant differences when calculating the LV volumes (p Conclusion Single-beat three-dimensional full volume acquisition seems to be superior to four-beat ECG-gated acquisition in measuring left ventricular volumes and ejection fraction in patients having atrial fibrillation. The variability is significantly lower both for ejection fraction and left ventricular volumes.</p

    Sex differences in response to maximal exercise stress test in trained adolescents

    No full text
    Abstract Background Sex comparisons between girls and boys in response to exercise in trained adolescents are missing and we investigated similarities and differences as a basis for clinical interpretation and guidance. Methods A total of 24 adolescent females and 27 adolescent males aged 13–19 years underwent a maximal bicycle exercise stress test with measurement of cardiovascular variables, cardiac output, lung volumes, metabolic factors/lactate concentrations and breath-by-breath monitoring of ventilation, and determination of peak VO2. Results Maximum heart rate was similar in females (191 ± 9 bpm) and males (194 ± 7 bpm), cardiac index at maximum exercise was lower in females (7.0 ± 1.0 l/min/m2) than in males (8.3 ± 1.4 l/min/m2, P 2 was lower in females (2.37 ± 0.34 l/min) than in males (3.38 ± 0.49 l/min, P 2 was normalized to leg muscle mass sex differences disappeared (females: 161 ± 21 ml/min/kg vs. males: 170 ± 23 ml/min/kg). The increase in cardiac index during exercise is the key factor responsible for the greater peak VO2 in adolescent boys compared to girls. Conclusions Differences in peak VO2 in adolescent boys and girls disappear when peak VO2 is normalized to estimated leg muscle mass and therefore provide a tool to conduct individual and intersex comparisons of fitness when evaluating adolescent athletes in aerobic sports.</p

    Sex differences in response to maximal exercise stress test in trained adolescents

    Get PDF
    BACKGROUND: Sex comparisons between girls and boys in response to exercise in trained adolescents are missing and we investigated similarities and differences as a basis for clinical interpretation and guidance. METHODS: A total of 24 adolescent females and 27 adolescent males aged 13–19 years underwent a maximal bicycle exercise stress test with measurement of cardiovascular variables, cardiac output, lung volumes, metabolic factors/lactate concentrations and breath-by-breath monitoring of ventilation, and determination of peak VO(2). RESULTS: Maximum heart rate was similar in females (191 ± 9 bpm) and males (194 ± 7 bpm), cardiac index at maximum exercise was lower in females (7.0 ± 1.0 l/min/m(2)) than in males (8.3 ± 1.4 l/min/m(2), P < 0.05). Metabolic responses and RQ at maximum exercise were similar (females: 1.04 ± 0.06 vs. males: 1.05 ± 0.05). Peak VO(2) was lower in females (2.37 ± 0.34 l/min) than in males (3.38 ± 0.49 l/min, P < 0.05). When peak VO(2) was normalized to leg muscle mass sex differences disappeared (females: 161 ± 21 ml/min/kg vs. males: 170 ± 23 ml/min/kg). The increase in cardiac index during exercise is the key factor responsible for the greater peak VO(2) in adolescent boys compared to girls. CONCLUSIONS: Differences in peak VO(2) in adolescent boys and girls disappear when peak VO(2) is normalized to estimated leg muscle mass and therefore provide a tool to conduct individual and intersex comparisons of fitness when evaluating adolescent athletes in aerobic sports

    Longitudinal strain analysis for assessment of early cardiotoxicity during anthracycline treatment in childhood sarcoma: A single center experience

    No full text
    Abstract Background The growing population of long‐term childhood cancer survivors encounter a substantial burden of cardiovascular complications. The highest risk of cardiovascular complications is associated with exposure to anthracyclines and chest radiation. Longitudinal cardiovascular surveillance is recommended for childhood cancer patients; however, the optimal methods and timing are yet to be elucidated. Aims We aimed to investigate the feasibility of different echocardiographic methods to evaluate left ventricular systolic function in retrospective datasets, including left ventricular ejection fraction (LVEF), fractional shortening (FS), global longitudinal strain (GLS) and longitudinal strain (LS) as well as the incidence and timing of subclinical left ventricular dysfunction detected by these methods. Methods and Results A retrospective longitudinal study was performed with re‐analysis of longitudinal echocardiographic data, acquired during treatment and early follow‐up, including 41 pediatric sarcoma patients, aged 2.1–17.8 years at diagnosis, treated at Astrid Lindgren Children's Hospital, Stockholm, Sweden, during the period 2010–2021. All patients had received treatment according to protocols including high cumulative doxorubicin equivalent doses (≥250 mg/m2). In 68% of all 366 echocardiograms, LS analysis was feasible. Impaired LS values (40%, with concomitant impairment of either LVEF or FS in 20% and combined impairment of both LVEF and FS in <10%. Importantly, there were no cases of abnormal LVEF and FS without concomitant LS impairment. Conclusion Our findings demonstrate feasibility of LS in a majority of echocardiograms and a high incidence of impaired LS during anthracycline treatment for childhood sarcoma. We propose inclusion of LS in pediatric echocardiographic surveillance protocols
    corecore