644 research outputs found

    A numerical analysis of an Active Magnetic Regenerative Refrigerant system with a multi-layer regenerator

    No full text
    Abstract The Active Magnetic Regenerative Refrigeration (AMRR) cycle is a special kind of regenerator for the magnetic refrigerator, in which the magnetic material matrix works both as a refrigerating medium and as a heat regenerating medium, while the fluid flowing in the porous matrix works as a heat transfer medium. The performance of an AMRR cycle depends strongly on the behaviour of the adiabatic magnetization temperature change as a function of material temperature in the flow direction of the regenerator. In the present paper, a practical model for predicting the performance and efficiency of an AMRR cycle has been developed. The model simulates both the ferromagnetic material and the entire cycle of an AMR operating in conformity with a Brayton regenerative cycle. The model simulates different kinds of layered regenerators operating at their optimal operation point. The program study the Gd-x Tb1-x alloys as constituent materials for the regenerator over the temperature range 275 – 295 K, and Gdx Dy1-x alloys in the temperature range 260 – 280 K. With this model, the refrigeration capacity, the power consumption and consequently the coefficient of performance can be predicted. The results show a greater COP for the refrigerator based on the magnetocaloric technology compared with the COP of a classical vapour compression plant working between the same thermal levels

    Refrigeration plant exergetic analysis varying the compressor capacity

    Get PDF
    The paper presents an exergetic analysis of a vapour compressor refrigeration plant when the refrigeration capacity is controlled by varying the compressor speed. The aim is performance evaluation of both the whole plant and its individual components. The analysis of the exergy flow destroyed in each device of the plant varying the compressor speed has been carried out in order to determine the relative irreversibility of the plant components. The vapour compression plant is subjected to a commercially available cold store. The compressor working with R22, R407C and R507 and designed for a revolution speed corresponding to 50 Hz supply current frequency, has been used varying the frequency in the range 30–50 Hz. In this range, the most suitable working fluids proposed as substitutes of R22, as R407C (R32/R125/R134a 23/25/52% in mass), R507 (R125/R143A 50/50% in mass) and R417A (R125/R134a/R600 46.6/50/3.4% in mass), have been tested. The variable-speed compressor is fitted with a pulse-width modulated source inverter (PWM) predominantly used in medium power applications due to its relatively low cost and high efficiency. The basic difference between variable speed refrigeration and conventional refrigeration systems is in the control of the system capacity at part-load conditions. The conventional refrigeration systems are characterized by compressor on/off cycles arising from by the thermostatic control. On the contrary when the inverter is used the capacity of the refrigeration system is matched to the load regulating the compressor motor speed. When the control of the compressor capacity is obtained by varying its speed there is an energy saving with respect to the thermostatic control. The best results of the exergetic analysis have been obtained using R22 followed by the non-azeotropic mixture designed as R407C that confirms, among the fluid candidates R22 substitution a better performance, shown also at the compressor nominal speed

    Zeolite-based monoliths for water softening by ion exchange/precipitation process

    Get PDF
    In this work, the design of a monolithic softener obtained by geopolymer gel conversion is proposed. The softener used consists in a geopolymeric macroporous matrix functionalized by the co-crystallization of zeolite A and X in mixture. The dual nature of the proposed material promotes a softening process based on the synergistic effect of cation exchange and alkaline precipitation. A softening capacity of 90% and 54% for Ca2+ and Mg2+ respectively was attained in 24 h. In fact, the softener reported a Cation Exchange Capacity (CEC) value of 4.43 meq g−1. Technical features such as density, porosity and mechanical resistance were also measured. The use of this monolithic softener can improve performance and sustainability of hardness removal from tap water, reducing the production of sludge and adding the possibility to partially regenerate or reuse it

    Individual metering and submetering for cooling application

    Get PDF
    In 2012 the Energy Efficiency Directive (EED) has set mandatory installation of individual metering and submetering systems for accounting thermal energy consumption in buildings where centralized heating/cooling sources are present, when technically feasible and cost efficient. As a consequence, direct thermal energy meters or indirect heat accounting systems have spread widely in residential buildings, for metering and sub-metering in space heating applications. On the other hand, individual metering of thermal energy in space cooling is a difficult task, due to the very different types of cooling systems and to the lack of technical and legal metrology regulation. In this paper possible solutions available for direct metering and submetering of different types of centralized cooling systems are discussed. Indeed, for direct metering application, the cooling fluid flow metering is a particularly crucial issue due to small pipe diameters and different fluid properties. Thus, the authors carried out an experimental comparison between a Coriolis flow-meter and an ultrasonic clamp-on flow-meter in the cooling fluid circuit of a direct expansion system. Tests have been performed at different operative temperature differences between flow and return, showing relative errors within ± 10%

    A Comprehensive Energy Model for an Optimal Design of a Hybrid Refrigerated Van

    Get PDF
    The path towards decarbonization requires a progressive adaptation of all refrigeration systems, but only stationary ones have been intensely studied to improve their environmental performance. However, refrigerated transport is vital in the cold chain and must be considered in the green transition. In this paper, we propose a model for a hybrid refrigerated van that includes photovoltaic panels and electric batteries to decrease total greenhouse gas emissions from the engine. Thermal, electrical, and battery sub-models are considered and integrated into the comprehensive hybrid solar-powered refrigerated van model. Different technologies are compared, including lithium and lead-acid batteries and three different types of photovoltaic panels. The model was validated regarding van fuel consumption, showing a 4% deviation. Single and multiple delivery scenarios are considered to assess the energy, economic, and environmental benefits. Monthly CO2,e emissions could be reduced by 20% compared to a standard refrigerated van. Despite the environmental benefits provided by this sustainable solution, the payback period is still too long (above 20 years) because of the necessary investment to adapt the vehicle and considering fuel and electricity prices currently

    Prevalence Survey of Healthcare-Associated Infections and Antimicrobial Use at the University Hospital ?Paolo Giaccone?, Palermo, Italy

    Get PDF
    Introduction. Healthcare-associated infections (HAIs) and antimicrobial resistance are well known major public health threats. The first goal of our study was to describe the prevalence of HAI, while the second goal was to describe the antibiotic consumption at our University Hospital, ?P. Giaccone? in Palermo, Italy. Methods. A standardized methodology for a combined Point Prevalence Survey (PPS) on healthcare-associated infections (HAIs) and antimicrobial use in European acute care hospital developed by the European Centre for Disease Prevention and Control (ECDC) was piloted across Europe. The teaching Hospital ?P. Giaccone? in Palermo, Italy, participated in the study Results. Out of 328 surveyed patients, 12 (3.6%) had an HAI and 159 (48.5%) were receiving at least one antimicro- bial agent. Prevalence results were highest in intensive care units, with 17.6% patients with HAI. Bloodstream infections represented the most common type (50%) of HAI. Surgical prophylaxis was the indication for antimicrobial prescribing in 59 (37.1%) out of 159 patients and exceeded 24 hours in 54 (91.5%) cases. Discussion. The results suggest that in our hospital there was a frequent and inappropriate use of antimicrobials, especially in the setting of surgical prophylaxis

    Expanded Total Equivalent Warming Impact analysis on experimental standalone fresh-food refrigerator

    Get PDF
    The stand-alone refrigerators for fresh food storage represent a large part of supermarket refrigeration equip-ment. In these devices, the usage of refrigerants with low Global Warming Potential allows the mitigation of the direct emissions due to refrigerant leakages. In contrast, the indirect emissions in these components are highly dependent on the refrigerant charge, leakage, and equivalent emission factors related to the electricity pro-duction mix. The most used index to evaluate the environmental impact of refrigerators is the Total Equivalent Warming Impact. Despite that this index presents limits on the fixed evaluation of many parameters such as refrigerant charge, electricity consumption and, electricity emission factor. Otherwise in this study, an accurate evaluation of refrigerators emissions has been realised by using the innovative Expanded Total Equivalent Warming Impact method to an experimental stand-alone refrigerator by using a dynamic approach to evaluate direct and indirect contributions. The environmental analysis considers four different refrigerants and four different countries of location. The results show that the indirect emissions due to electricity consumption cover the highest share of emissions. In addition, the operating years affected by low refrigerant charges are respon-sible for emissions by greater than 25% compared to other ones. The hourly equivalent emissions due to elec-tricity consumption in countries characterized by an electricity generation mix mainly based on renewable and/ or nuclear plants show an indirect environmental impact up to 5 times lower than countries with a natural gas -based electricity production mix. The study also defines new strategies to reduce the environmental impact of the stand-alone refrigerator such as the use of photovoltaic systems combined with this technology or earlier maintenance processes that could determine an equivalent emission saving of up to 38%

    Plasma-arc-flow technology for sustainable treatment of high-impact fluid waste. A graphene-based material for industrial-wastewater purification

    Get PDF
    The research presented aimed to address the treatment of fluid waste with significant environmental impact by utilizing plasma technology, specifically plasma arc flow (PAF). The goal was to develop a novel purification material based on graphene for industrial applications and to optimize the treatment process. Analysis and monitoring of a submerged arc plasma reactor were the main goals of this research. This entailed a careful examination of the incoming wastewater that needed to be treated with the goal of identifying its precise composition characteristics with the relative tolerances needed for the reactions that were to follow in the reactor. The focus of the analysis was on input-parameter optimization, production of characteristic curves, and analysis of the factors affecting hydrogen evolution in syngas. Additionally, the study investigated how to determine the best viscosity for a particular input matrix by carrying out an evaluation study. The effects of this parameter were thought to be reduced by preheating the incoming wastewater through heat recovery. The long-term objective of the research is to create filters that can purify the water used and produced in gasification processes as well as to characterize the fixed reside from the gasifier for potential conversion into graphene-based material. In addition, this work acknowledges that additional experiments are required to validate its purifying capacity on wastewater produced by various industrial processes. Moreover, the inclusion of plans to model the evolution of hydrogen in PAF using the CHEMCAD software® and defining guidelines for optimizing parameters for enhanced energy efficiency showcased the research’s ambition to expand and refine its scope. Finding the best plant solutions that can significantly reduce electricity consumption is the ultimate goal. In summary, the study demonstrated significant advancement in the analysis and optimization of fluid-waste treatment with high environmental impact through the use of plasma technology, specifically PAF. A thorough and forward-looking approach was demonstrated by the use of modeling software, experimental studies, and plans for future research. The potential creation of graphene-based filters and the use of the fixed residue as a useful material further highlight the innovativeness of this research
    • …
    corecore