6 research outputs found

    Urban Facades: Integration of TiO2 coating into facade elements of historical buildings in Athens for air purification purposes

    No full text
    In the last few decades, air pollution constitutes a major global problem that results in adverse effects on human’s health, nature and the built environment. Many abatement strategies have been adopted for its combat in all these different fields. This graduation project focuses on the built environment and tackles the application of TiO2 on facades of existing buildings with historical significance in the city of Athens. TiO2 is a promising photocatalytic material, capable of neutralizing air pollutants via the mechanism of photocatalysis and under certain environmental conditions. Its use aims at a wider application in urban landscapes, in order to alleviate the air pollution levels. This widespread application can be achieved by the creation of 3 different TiO2 application levels that can be applied on the different facade components. The choice of application is realized mainly via the assessment of their NOx efficiency, the assessment of values employed in the field of conservation as well as their effect on cost. This evaluation takes place through a number of steps that a designer can follow for the selection of the suitable level as well as for the components that can eventually be modified.In the current thesis, this set of steps/roadmap is presented and validated with the help of an actual case study, where the balconies are the main chosen facade element undergoing alterations of the 2nd level. It goes without saying that the flow can be followed and applied for different components, different buildings or even in different cities and locations. Athens is simply a representative example for this cause. Since the main goal of the project is the optimum performance of TiO2, a series of different balcony panels are designed via the manipulation of surface area and roughness, two very crucial factors for the successful activation of photocatalysis and pollutant neutralization. The panels undergo 3 different analyses: radiation, wind and NOx removal with a successive evaluation, resulting in one ideal geometry, whose NOx levels are compared to those prior to its implementation and those of the 1st application level.The final part of the graduation project focuses on the results yielded by these different analyses and the conclusions that are pointed out and could prove pivotal for a designer. After the application of the panels to the chosen street canyon, the evaluation of the NOx abatement efficiency, the value and cost of each tested scenario, results indicate that the 2nd application level of TiO2 is more efficient than the 1st in terms of NOx removal efficiency. Nevertheless, a combination of both levels could considerably balance all 3 criteria, namely the aspect of NOx removal, values and cost.Keywords: Urban Facades I Air Pollution I TiO2 I Air Purification I Historical SignificanceArchitecture, Urbanism and Building Sciences | Building Technolog

    Comparative pharmacokinetics of the three echinocandins in ICU patients

    No full text
    International audienceAbstract Background We conducted a prospective study in ICU patients of two tertiary hospitals in order to determine basic pharmacokinetic (PK) parameters, associated variation and target attainment rates for anidulafungin, micafungin and caspofungin. Methods Serum samples from patients treated for 7 days with the standard doses of anidulafungin (N = 13), micafungin (N = 14) or caspofungin (N = 7) were analysed by validated chromatographic methods. PK parameters determined with non-compartmental analysis were correlated with demographic, laboratory and disease severity characteristics. The percentages of patients attaining drug exposures described in the summary of product characteristics (SmPC) documents and preclinical PK/PD targets for stasis were estimated. Results The median (range) AUC24 was 101.46 (54.95–274.15) mg·h/L for anidulafungin, 79.35 (28.00–149.30) mg·h/L for micafungin and 48.46 (19.44–103.69) mg·h/L for caspofungin. The interindividual variability of anidulafungin, micafungin and caspofungin AUC24 was 46%–58%, attributed mainly to variability in volume of distribution (V), clearance (CL) and in both V and CL, respectively. Significant correlations were found between anidulafungin AUC24 and BMI (rs = −0.670, P = 0.012) and liver enzymes (rs = 0.572–0.665, P = 0.013–0.041) and between caspofungin Cmin and transaminase levels (rs = −0.775 to −0.786, P = 0.036–0.041). Less than 50% of our patients attained the corresponding SmPC median AUC24s and none of the patients attained the PK/PD targets for Candida albicans and Candida parapsilosis. Conclusions Anidulafungin exposure in ICU patients was comparable with that reported in non-ICU patients and in healthy volunteers. Micafungin exposure was comparable to that of other patients but ∼30% lower than that in healthy volunteers, whereas caspofungin exposure was rather low (∼50% lower than in healthy volunteers). Larger interindividual variability (50%–60%) was recorded in ICU patients compared with other groups for all three echinocandins

    Weaning from mechanical ventilation in intensive care units across 50 countries (WEAN SAFE): a multicentre, prospective, observational cohort study

    No full text
    Background Current management practices and outcomes in weaning from invasive mechanical ventilation are poorly understood. We aimed to describe the epidemiology, management, timings, risk for failure, and outcomes of weaning in patients requiring at least 2 days of invasive mechanical ventilation. Methods WEAN SAFE was an international, multicentre, prospective, observational cohort study done in 481 intensive care units in 50 countries. Eligible participants were older than 16 years, admitted to a participating intensive care unit, and receiving mechanical ventilation for 2 calendar days or longer. We defined weaning initiation as the first attempt to separate a patient from the ventilator, successful weaning as no reintubation or death within 7 days of extubation, and weaning eligibility criteria based on positive end-expiratory pressure, fractional concentration of oxygen in inspired air, and vasopressors. The primary outcome was the proportion of patients successfully weaned at 90 days. Key secondary outcomes included weaning duration, timing of weaning events, factors associated with weaning delay and weaning failure, and hospital outcomes. This study is registered with ClinicalTrials.gov, NCT03255109. Findings Between Oct 4, 2017, and June 25, 2018, 10 232 patients were screened for eligibility, of whom 5869 were enrolled. 4523 (77·1%) patients underwent at least one separation attempt and 3817 (65·0%) patients were successfully weaned from ventilation at day 90. 237 (4·0%) patients were transferred before any separation attempt, 153 (2·6%) were transferred after at least one separation attempt and not successfully weaned, and 1662 (28·3%) died while invasively ventilated. The median time from fulfilling weaning eligibility criteria to first separation attempt was 1 day (IQR 0–4), and 1013 (22·4%) patients had a delay in initiating first separation of 5 or more days. Of the 4523 (77·1%) patients with separation attempts, 2927 (64·7%) had a short wean (≤1 day), 457 (10·1%) had intermediate weaning (2–6 days), 433 (9·6%) required prolonged weaning (≥7 days), and 706 (15·6%) had weaning failure. Higher sedation scores were independently associated with delayed initiation of weaning. Delayed initiation of weaning and higher sedation scores were independently associated with weaning failure. 1742 (31·8%) of 5479 patients died in the intensive care unit and 2095 (38·3%) of 5465 patients died in hospital. Interpretation In critically ill patients receiving at least 2 days of invasive mechanical ventilation, only 65% were weaned at 90 days. A better understanding of factors that delay the weaning process, such as delays in weaning initiation or excessive sedation levels, might improve weaning success rates

    Weaning from mechanical ventilation in intensive care units across 50 countries (WEAN SAFE): a multicentre, prospective, observational cohort study

    No full text
    International audienceBackground: Current management practices and outcomes in weaning from invasive mechanical ventilation are poorly understood. We aimed to describe the epidemiology, management, timings, risk for failure, and outcomes of weaning in patients requiring at least 2 days of invasive mechanical ventilation. Methods: WEAN SAFE was an international, multicentre, prospective, observational cohort study done in 481 intensive care units in 50 countries. Eligible participants were older than 16 years, admitted to a participating intensive care unit, and receiving mechanical ventilation for 2 calendar days or longer. We defined weaning initiation as the first attempt to separate a patient from the ventilator, successful weaning as no reintubation or death within 7 days of extubation, and weaning eligibility criteria based on positive end-expiratory pressure, fractional concentration of oxygen in inspired air, and vasopressors. The primary outcome was the proportion of patients successfully weaned at 90 days. Key secondary outcomes included weaning duration, timing of weaning events, factors associated with weaning delay and weaning failure, and hospital outcomes. This study is registered with ClinicalTrials.gov, NCT03255109. Findings: Between Oct 4, 2017, and June 25, 2018, 10 232 patients were screened for eligibility, of whom 5869 were enrolled. 4523 (77·1%) patients underwent at least one separation attempt and 3817 (65·0%) patients were successfully weaned from ventilation at day 90. 237 (4·0%) patients were transferred before any separation attempt, 153 (2·6%) were transferred after at least one separation attempt and not successfully weaned, and 1662 (28·3%) died while invasively ventilated. The median time from fulfilling weaning eligibility criteria to first separation attempt was 1 day (IQR 0–4), and 1013 (22·4%) patients had a delay in initiating first separation of 5 or more days. Of the 4523 (77·1%) patients with separation attempts, 2927 (64·7%) had a short wean (≤1 day), 457 (10·1%) had intermediate weaning (2–6 days), 433 (9·6%) required prolonged weaning (≥7 days), and 706 (15·6%) had weaning failure. Higher sedation scores were independently associated with delayed initiation of weaning. Delayed initiation of weaning and higher sedation scores were independently associated with weaning failure. 1742 (31·8%) of 5479 patients died in the intensive care unit and 2095 (38·3%) of 5465 patients died in hospital. Interpretation: In critically ill patients receiving at least 2 days of invasive mechanical ventilation, only 65% were weaned at 90 days. A better understanding of factors that delay the weaning process, such as delays in weaning initiation or excessive sedation levels, might improve weaning success rates. Funding: European Society of Intensive Care Medicine, European Respiratory Society

    Weaning from mechanical ventilation in intensive care units across 50 countries (WEAN SAFE): a multicentre, prospective, observational cohort study

    No full text
    Background: Current management practices and outcomes in weaning from invasive mechanical ventilation are poorly understood. We aimed to describe the epidemiology, management, timings, risk for failure, and outcomes of weaning in patients requiring at least 2 days of invasive mechanical ventilation. Methods: WEAN SAFE was an international, multicentre, prospective, observational cohort study done in 481 intensive care units in 50 countries. Eligible participants were older than 16 years, admitted to a participating intensive care unit, and receiving mechanical ventilation for 2 calendar days or longer. We defined weaning initiation as the first attempt to separate a patient from the ventilator, successful weaning as no reintubation or death within 7 days of extubation, and weaning eligibility criteria based on positive end-expiratory pressure, fractional concentration of oxygen in inspired air, and vasopressors. The primary outcome was the proportion of patients successfully weaned at 90 days. Key secondary outcomes included weaning duration, timing of weaning events, factors associated with weaning delay and weaning failure, and hospital outcomes. This study is registered with ClinicalTrials.gov, NCT03255109. Findings: Between Oct 4, 2017, and June 25, 2018, 10 232 patients were screened for eligibility, of whom 5869 were enrolled. 4523 (77·1%) patients underwent at least one separation attempt and 3817 (65·0%) patients were successfully weaned from ventilation at day 90. 237 (4·0%) patients were transferred before any separation attempt, 153 (2·6%) were transferred after at least one separation attempt and not successfully weaned, and 1662 (28·3%) died while invasively ventilated. The median time from fulfilling weaning eligibility criteria to first separation attempt was 1 day (IQR 0-4), and 1013 (22·4%) patients had a delay in initiating first separation of 5 or more days. Of the 4523 (77·1%) patients with separation attempts, 2927 (64·7%) had a short wean (≤1 day), 457 (10·1%) had intermediate weaning (2-6 days), 433 (9·6%) required prolonged weaning (≥7 days), and 706 (15·6%) had weaning failure. Higher sedation scores were independently associated with delayed initiation of weaning. Delayed initiation of weaning and higher sedation scores were independently associated with weaning failure. 1742 (31·8%) of 5479 patients died in the intensive care unit and 2095 (38·3%) of 5465 patients died in hospital. Interpretation: In critically ill patients receiving at least 2 days of invasive mechanical ventilation, only 65% were weaned at 90 days. A better understanding of factors that delay the weaning process, such as delays in weaning initiation or excessive sedation levels, might improve weaning success rates. Funding: European Society of Intensive Care Medicine, European Respiratory Society
    corecore