201 research outputs found
Which are the most reliable predictors of recurrence of atrial fibrillation after transcatheter ablation?: a meta-analysis.
Context: Transcatheter ablation of atrial fibrillation (AF) has undergone important development, with acceptable midterm results in terms of the safety and recurrence. A meta-analysis was performed to identify the periprocedural complications, midterm success rates and predictors of recurrence after AF ablation. Methods and results: 4357 patients with paroxysmal AF, 1083 with persistent AF and 1777 with long standing AF were included. The pooled analysis showed that there was an in-hospital complication rate of tamponade requiring drainage of 0.99% (0.44-1.54; CI 99%), stroke with neurological persistent impairment of 0.22% (0.04-0.47; CI 99%), and stroke without of 0.36% (0.03-0.70; CI 99%) After a follow up of 22 (13-28) months and 1.23 (1.19-1.5; CI 99%) procedures per patient, the AF recurrence rate was 31.20% (24.87-34.81; CI 99%). The persistent AF patients exhibited a greater risk of recurrence after the first ablation (OR 1.78 [1.14, 2.77] CI 99%), but a trend towards non significance was present in the patients with more than one procedure (OR 1.69 [0.95, 3.00] CI 99%). The most powerful predictors of an AF ablation failure in the overall population were a recurrence within 30-days (OR 4.30; 2.00-10.80), valvular AF (OR 5.20; 2.22-9.50) and a left atrium diameter of more than 50 mm (OR 5.10 2.00-12.90; all CI 95%). Conclusions: Persistent AF remains burdened from higher recurrence rates, however not so following redo-procedures. Three predictors, valvular AF, a left atrium diameter longer than 50 mm and recurrence within 30 days, could be appraised to drive selection of patients and therapeutic strategy. (C) 2012 Elsevier Ireland Ltd. All rights reserved
A switchable controlled-NOT gate in a spin-chain NMR quantum computer
A method of switching a controlled-NOT gate in a solid-stae NMR quantum
computer is presented. Qubits of I=1/2 nuclear spins are placed periodically
along a quantum spin chain (1-D antiferromagnet) having a singlet ground state
with a finite spin gap to the lowest excited state caused by some quantum
effect. Irradiation of a microwave tuned to the spin gap energy excites a
packet of triplet magnons at a specific part of the chain where control and
target qubits are involved. The packet switches on the Suhl-Nakamura
interaction between the qubits, which serves as a controlled NOT gate. The
qubit initialization is achieved by a qubit initializer consisting of
semiconducting sheets attached to the spin chain, where spin polarizations
created by the optical pumping method in the semiconductors are transferred to
the spin chain. The scheme allows us to separate the initialization process
from the computation, so that one can optimize the computation part without
being restricted by the initialization scheme, which provides us with a wide
selection of materials for a quantum computer.Comment: 8 pages, 5 figure
Specific, sensitive and rapid detection of human plasmodium knowlesi infection by loop-mediated isothermal amplification (LAMP) in blood samples
<p>Abstract</p> <p>Background</p> <p>The emergence of <it>Plasmodium knowlesi </it>in humans, which is in many cases misdiagnosed by microscopy as <it>Plasmodium malariae </it>due to the morphological similarity has contributed to the needs of detection and differentiation of malaria parasites. At present, nested PCR targeted on <it>Plasmodium </it>ssrRNA genes has been described as the most sensitive and specific method for Plasmodium detection. However, this method is costly and requires trained personnel for its implementation. Loop-mediated isothermal amplification (LAMP), a novel nucleic acid amplification method was developed for the clinical detection of <it>P. knowlesi</it>. The sensitivity and specificity of LAMP was evaluated in comparison to the results obtained via microscopic examination and nested PCR.</p> <p>Methods</p> <p>LAMP assay was developed based on <it>P. knowlesi </it>genetic material targeting the apical membrane antigen-1 (AMA-1) gene. The method uses six primers that recognize eight regions of the target DNA and it amplifies DNA within an hour under isothermal conditions (65°C) in a water-bath.</p> <p>Results</p> <p>LAMP is highly sensitive with the detection limit as low as ten copies for AMA-1. LAMP detected malaria parasites in all confirm cases (n = 13) of <it>P. knowlesi </it>infection (sensitivity, 100%) and none of the negative samples (specificity, 100%) within an hour. LAMP demonstrated higher sensitivity compared to nested PCR by successfully detecting a sample with very low parasitaemia (< 0.01%).</p> <p>Conclusion</p> <p>With continuous efforts in the optimization of this assay, LAMP may provide a simple and reliable test for detecting <it>P. knowlesi </it>malaria parasites in areas where malaria is prevalent.</p
Influence of secondary neutrons induced by proton radiotherapy for cancer patients with implantable cardioverter defibrillators
<p>Abstract</p> <p>Background</p> <p>Although proton radiotherapy is a promising new approach for cancer patients, functional interference is a concern for patients with implantable cardioverter defibrillators (ICDs). The purpose of this study was to clarify the influence of secondary neutrons induced by proton radiotherapy on ICDs.</p> <p>Methods</p> <p>The experimental set-up simulated proton radiotherapy for a patient with an ICD. Four new ICDs were placed 0.3 cm laterally and 3 cm distally outside the radiation field in order to evaluate the influence of secondary neutrons. The cumulative in-field radiation dose was 107 Gy over 10 sessions of irradiation with a dose rate of 2 Gy/min and a field size of 10 × 10 cm<sup>2</sup>. After each radiation fraction, interference with the ICD by the therapy was analyzed by an ICD programmer. The dose distributions of secondary neutrons were estimated by Monte-Carlo simulation.</p> <p>Results</p> <p>The frequency of the power-on reset, the most serious soft error where the programmed pacing mode changes temporarily to a safety back-up mode, was 1 per approximately 50 Gy. The total number of soft errors logged in all devices was 29, which was a rate of 1 soft error per approximately 15 Gy. No permanent device malfunctions were detected. The calculated dose of secondary neutrons per 1 Gy proton dose in the phantom was approximately 1.3-8.9 mSv/Gy.</p> <p>Conclusions</p> <p>With the present experimental settings, the probability was approximately 1 power-on reset per 50 Gy, which was below the dose level (60-80 Gy) generally used in proton radiotherapy. Further quantitative analysis in various settings is needed to establish guidelines regarding proton radiotherapy for cancer patients with ICDs.</p
Working without a blindfold: the critical role of diagnostics in malaria control
Diagnostic testing for malaria has for many years been eschewed, lest it be an obstacle to the delivery of rapid, life-saving treatment. The approach of treating malaria without confirmatory testing has been reinforced by the availability of inexpensive treatment with few side effects, by the great difficulty of establishing quality-assured microscopy in rural and resource-poor settings, and by the preeminence of malaria as a cause of important fever in endemic regions. Within the last decade, all three of these factors have changed. More expensive artemisinin combination therapy (ACT) has been widely introduced, simple immunochromatographic tests for malaria have been developed that can be used as an alternative to microscopy by village health workers, and recognition of the health cost of mismanaging non-malarial fever is growing. In most of the world a small fraction of fever is due to malaria, and reflex treatment with ACT does not make medical or economic sense. Global malaria control efforts have been energized by the availability of new sources of funding, and by the rapid reduction in malaria prevalence in a number of settings where bed nets, indoor residual spraying with insecticides, and ACT have been systematically deployed. This momentum has been captured by a new call for malaria elimination. Without wide implementation of accurate and discriminating diagnostic testing, and reporting of results, most fever will be inappropriately managed, millions of doses of ACT will be wasted, and malaria control programmes will be blindfolded to the impact of their efforts
Tissue factor expression as a possible determinant of thromboembolism in ovarian cancer
Ovarian cancer, and clear cell carcinoma in particular, reportedly increases the risk of venous thromboembolism (VTE). However, the mechanisms remain unclear. Tissue factor (TF) supposedly represents a major factor in the procoagulant activities of cancer cells. The present study examined the involvement of TF expression in VTE for patients with ovarian cancer. Subjects comprised 32 consecutive patients (mean age 49.8 years) with histologically confirmed ovarian cancer. Presence of VTE was examined using a combination of clinical features, D-dimer levels and venous ultrasonography. Immunohistochemical analysis was used to evaluate TF expression into 4 degrees. Venous thromboembolism was identified in 10 of the 32 patients (31%), including five of the 11 patients with clear cell carcinoma. Tissue factor expression was detected in cancer tissues from 24 patients and displayed significant correlations with VTE development (P=0.0003), D-dimer concentration (P=0.003) and clear cell carcinoma (P<0.05). Multivariate analysis identified TF expression as an independent predictive factor of VTE development (P<0.05). Tissue factor (TF) expression is a possible determinant of VTE development in ovarian cancer. In particular, clear cell carcinoma may produce excessive levels of TF and is more likely to develop VTE
- …