29 research outputs found

    The Utility and Safety of a Continuous Glucose Monitoring System (CGMS) in Asphyxiated Neonates during Therapeutic Hypothermia

    No full text
    Background: The present study was designed to assess the feasibility and reliability of a Continuous Glucose Monitoring System (CGMS) in a population of asphyxiated neonates during therapeutic hypothermia. Methods: This non-randomized feasibility study was conducted in the Neonatal Intensive Care Unit (NICU) facilities of Fondazione Policlinico A. Gemelli IRCSS. Infants matching the criteria for hypothermic treatment were included in this study and were connected to the CGMS (Medtronic, Northridge, CA, USA) within the first 12 h of life. Hypoglycemia was defined as a glucose value ≤ 47 mg/dL, and hyperglycemia was defined as a glucose value ≥ 180 mg/dL. Data obtained via the CGMS were compared with those obtained via a point-of-care blood glucometer (GTX). Results: The two measuring techniques were compared using the Modified Clarke Error Grid (MCEG). Sixteen infants were enrolled. The sensor had an average (standard deviation) duration of 93 (38) h. We collected 119 pairs of glycemia values (CGMVs) from the CGMS vs. GTX measurements. The CGMS detected twenty-five episodes of hypoglycemia and three episodes of hyperglycemia. All the CGMVs indicating hyperglycemia matched with the blood sample taken via the point-of-care glucometer. Conclusions: The use of a CGMS would be useful as it could detect more episodes of disglycemia than standard care. Our data show poor results in terms of the accuracy of the CGMS in this particular setting

    Lung Ultrasound in the Early Diagnosis and Management of the Mild Form of Meconium Aspiration Syndrome: A Case Report

    No full text
    MAS is a common cause of neonatal respiratory distress in term and post-term neonates. Meconium staining of the amniotic fluid occurs in about 10–13% of normal pregnancies, and about 4% of these infants develop respiratory distress. In the past, MAS was diagnosed mainly on the basis of history, clinical symptoms, and chest radiography. Several authors have addressed the ultrasonographic assessment of the most common respiratory patterns in neonates. In particular, MAS is characterised by a heterogeneous alveolointerstitial syndrome, subpleural abnormalities with multiple lung consolidations, characterised by a hepatisation aspect. We present six cases of infants with a clinical history of meconium-stained fluid who presented with respiratory distress at birth. Lung ultrasound allowed the diagnosis of MAS in all the studied cases, despite the mild clinical picture. All children had the same ultrasound pattern with diffuse and coalescing B-lines, pleural line anomalies, air bronchograms, and subpleural consolidations with irregular shapes. These patterns were distributed in different areas of the lungs. These signs are specific enough to distinguish between MAS and other causes of neonatal respiratory distress, allowing the clinician to optimise therapeutic management

    Internet Addiction: Starting the Debate on Health and Well-Being of Children Overexposed to Digital Media

    No full text
    Previous articles have discussed the importance of children’s well-being and its role in different areas of children’s health, such as well-child care and child-friendly health care. The goal of this commentary is to raise pediatricians’ awareness on the risks of children’s overexposure to digital media. It is important to protect the psychological and emotional health of children from uncontrolled external influences to preserve their well-being. Authors also emphasize the importance of alerting parents and tutors to the risks related to the unrefrained use of the Internet
    corecore