36 research outputs found

    A negative expiratory pressure test during wakefulness for evaluating the risk of obstructive sleep apnea in patients referred for sleep studies

    Get PDF
    OBJECTIVE: Obstructive sleep apnea is characterized by increased upper airway collapsibility during sleep. The present study investigated the use of the negative expiratory pressure test as a method to rule out obstructive sleep apnea. METHODS: Flow limitation was evaluated in 155 subjects. All subjects underwent a diurnal negative expiratory pressure test and a nocturnal sleep study. The severity of sleep apnea was determined based on the apneahypopnea index. Flow limitation was assessed by computing the exhaled volume at 0.2, 0.5, and 1.0 s (V0.2, V0.5, and V1.0, respectively) during the application of a negative expiratory pressure and expressed as a percentage of the previous exhaled volume. Receiver-operating characteristic curves were constructed to identify the optimal threshold volume at 0.2, 0.5, and 1.0 s for obstructive sleep apnea detection. RESULTS: Mean expiratory volumes at 0.2 and 0.5 s were statistically higher (p <0.01) in healthy subjects than in all obstructive sleep apneic groups. Increasing disease severity was associated with lower expiratory volumes. The V0.2 (%) predictive parameters for the detection of sleep apnea were sensitivity (81.1%), specificity (93.1%), PPV (98.1%), and NPV (52.9%). Sensitivity and NPV were 96.9% and 93.2%, respectively, for moderate-to-severe obstructive sleep apnea, and both were 100% for severe obstructive sleep apnea. CONCLUSION: Flow limitation measurement by V 0.2 (%) during wakefulness may be a very reliable method to identify obstructive sleep apnea when the test is positive and could reliably exclude moderate and severe obstructive sleep apnea when the test is negative. The negative expiratory pressure test appears to be a useful screening test for suspected obstructive sleep apnea

    Extreme REM Rebound during Continuous Positive Airway Pressure Titration for Obstructive Sleep Apnea in a Depressed Patient

    No full text
    A 20% increase in REM sleep duration has been proposed as a threshold to identify REM rebound in patients with obstructive sleep apnea (OSA) who start continuous positive airway pressure (CPAP) treatment. We describe the case of one patient with OSA who showed an unexpectedly high degree of REM rebound during titration of CPAP. A 34-year-old man was diagnosed with OSA. He remained untreated for many years, during which he developed systemic hypertension, depression, and severe daytime somnolence. When he was reevaluated sixteen years later, his Epworth sleepiness score was 18, and his OSA had greatly worsened (apnea/hypopnea index: 47, lowest nocturnal saturation: 57%). He underwent a successful CPAP titration during nocturnal polysomnography. Electroencephalographic analysis of the sleep recording revealed a huge amount of REM sleep, accounting for 72% of the total sleep time. When asked, the patient referred that he had suddenly interrupted paroxetine assumption three days before the polysomnography. The very large REM rebound observed in this patient could be due to additional effects of initiation of CPAP therapy and suspension of antidepressive treatment. This case does not report any dangerous consequence, but sudden antidepressive withdrawal could be dangerous for patients with OSA who develop hypoventilation during REM sleep with CPAP application
    corecore