24 research outputs found

    MNE’s Regional Location Choice - A Comparative Perspective on East Germany, the Czech Republic and Poland

    Get PDF
    The focus of this article is the empirical identification of factors influencing Foreign Direct Investment (FDI) in transition economies on a regional level (NUTS 2). The analysis is designed as benchmark between three neighboring post-communist regions, i.e. East Germany, the Czech Republic and Poland. Their different transition paths have not only resulted in economic differences. We can also observe today that the importance of pull factors for FDI varies significantly across the regions. This analysis shows that in comparison with Poland and the Czech Republic, East Germany’s major benefit is its purchasing power, its geographical proximity to West European markets, and its modern infrastructure. Furthermore, the analysis suggests that intra-industry linkages such as specialization and agglomeration economies are relevant factors for the location decision of foreign investors. This result can help to explain the regional divergence of FDI streams in transition economies.multinational enterprises, international business, regional economic activity: growth, development, and changes, discrete choice

    The "Free Voters": A Decent Alternative for Conservatives?

    Get PDF
    The Free Voters (Freie Wähler) party is becoming a more serious competitor in the German party system. It gained parliamentary representation in the Rhineland Palatine in 2021 and has been governing with the Christian Social Union in Bavaria since 2018. In addition, the Free Voters party now holds two of the 96 German parliamentary member positions in the European Parliament and is, at the federal level, the extraparliamentary opposition party with the greatest number of votes. Nevertheless, there has, to date, been no analysis examining people's motives for voting for the Free Voters or exploring their future openness to voting for the party. This article addresses this oversight by identifying factors, based on population-representative data from the 2021 Bundestag elections, that favour openness and voting for this increasingly influential party. Our analysis shows that a more general dissatisfaction with democratic outputs, a conservative attitude, and low perceptions of spatial distance from the political positions of the Free Voters have significant positive effects.Die Freien Wähler entwickeln sich zu einem ernstzunehmenden Konkurrenten im deutschen Parteiensystem. Sie sind 2021 in den rheinland-pfälzischen Landtag eingezogen und regieren seit 2018 gemeinsam mit der CSU in Bayern. Zudem stellen die Freien Wähler mittlerweile zwei der 96 deutschen Abgeordneten im Europäischen Parlament und sind auf Bundesebene die stimmenstärkste außerparlamentarische Oppositionspartei. Dennoch gibt es bisher keine Analyse, die die Motive der Wähler:innen für die Wahl der Freien Wähler oder eine mögliche zukünftige Bereitschaft, die Partei zu wählen, untersucht. Dieser Artikel behebt dieses Defizit, indem er auf der Grundlage von bevölkerungsrepräsentativen Daten zur Bundestagswahl 2021 Faktoren identifiziert, die die Offenheit und die Stimmabgabe für diese zunehmend einflussreiche Partei begünstigen. Unsere Analyse zeigt, dass eine allgemeinere Unzufriedenheit mit der demokratischen Performanz, eine konservative Grundhaltung sowie eine geringe wahrgenommene räumliche Distanz zu den politischen Positionen der Freien Wähler positive Effekte haben

    Selective inactivation of hypomethylating agents by SAMHD1 provides a rationale for therapeutic stratification in AML.

    Get PDF
    Hypomethylating agents decitabine and azacytidine are regarded as interchangeable in the treatment of acute myeloid leukemia (AML). However, their mechanisms of action remain incompletely understood, and predictive biomarkers for HMA efficacy are lacking. Here, we show that the bioactive metabolite decitabine triphosphate, but not azacytidine triphosphate, functions as activator and substrate of the triphosphohydrolase SAMHD1 and is subject to SAMHD1-mediated inactivation. Retrospective immunohistochemical analysis of bone marrow specimens from AML patients at diagnosis revealed that SAMHD1 expression in leukemic cells inversely correlates with clinical response to decitabine, but not to azacytidine. SAMHD1 ablation increases the antileukemic activity of decitabine in AML cell lines, primary leukemic blasts, and xenograft models. AML cells acquire resistance to decitabine partly by SAMHD1 up-regulation. Together, our data suggest that SAMHD1 is a biomarker for the stratified use of hypomethylating agents in AML patients and a potential target for the treatment of decitabine-resistant leukemia

    Studien zur Optimierung und Anwendung von Proteinbiochips

    No full text
    1\. Contents 1 2\. Introduction 6 3\. Objectives 25 4\. Material and Methods 27 5\. Results 51 6\. Discussion 90 7\. Summary 107 8\. Appendix 113The performance of proteins and antibody microarrays is dependent on various factors, one of which is the use of an appropriate microarray surface for the immobilisation of either protein or antibody sample. For optimisation of the technology an evaluation of the properties of 8 optimised surfaces was conducted in the context of it use in both, protein and antibody microarray technology. The comparison was performed under the same conditions as earlier studies with HSA and polyclonal anti-fibrinogen antibodies as model interaction partners. The functionality of all new slide coatings was demonstrated and the mean signal to spotted concentration ratio as well as the detection limits and the coefficients of variation were evaluated. Moreover, new concepts for slide coatings such as dendrimer and PEG-epoxy slides were assessed and improved qualities of such slide surfaces were observed. Optimal slide coatings for antibody and protein chips were proposed and the requirements for both technologies were discussed. Based on these optimisations, a new technology for the multiplex analysis for compounds on microarrays was developed, since current solutions, such as conventional microarrays, microfluidic systems and chips bearing microwells lack the possibility to screen several analytes on different immobilised binders at a time or require complicated liquid handling, surface modifications, or additional equipment. In the new approach, an immunoassay was performed using standard surfaces and machinery already available for microarray technology for multiplex analysis on a standard microscope slide without the requirement for wells or tubes to separate the samples. The new multiple spotting technique (MIST) comprises immobilisation of a binder onto a surface and subsequent spotting of the second compound, comprised in a hygroscopic buffer, on the same spot, on top of the immobilised binder. It was shown, that the analytes bind their ligands immediately, within the confined space of separate droplets on the chip surface, thereby eliminating the need for extra incubation time. Furthermore, the feasibility of the new technique was illustrated by spotting dilution rows of proteins or monoclonal and polyclonal antibodies on top of their immobilised interaction partners with a sensitivity of as little as 400 zeptomoles (240,000 molecules) of analyte. Specificity and compatibility to commonly used techniques such as total incubation was displayed by specific recognition of a protein by an equimolar mixture of antibodies and subsequent detection by a total incubation with labelled secondary antibodies. The same approach was used to facilitate the identification of high-affinity binders from a great variety of phage display- derived recombinant antibodies. While the selection process for phage displayed antibody fragments itself has been automated, the bottleneck was shifted further downstream to the identification of monoclonal binders obtained from the selections. Using the new approach recombinant antibody fragments were expressed in a single inoculation and expression step and subjected without purification directly to their immobilised antigens. Since immobilisation of the scFv�s was not possible so far due to loss of functionality, the multiplex assay represents a major improvement and allows automated high-throughput screening of phage-display derived selections with comparable sensitivity to the commonly used ELISA. Moreover, manual interaction steps were minimised and the technique was streamlined to be accessible within the automated selection procedure. ...Die Qualität von Protein- und Antiköper-Mikroarrays ist von vielen Faktoren abhängig. Ein wichtiger Faktor hierbei ist die Oberflächenchemie, welche spezifisch die jeweiligen Proteine oder Antiköper an die Oberfläche bindet. Zur Optimierung der Mikroarray-Technologie wurde ein Vergleich von acht für Protein und Antikörper Mikroarray optimierte Oberflächenchemien mit HSA und polyklonalen anti-Fibrinogen Antikörpern als Modellprotein bzw. Modellantikörper unter de ngleichen Bedingungen wie frühere Studien durchgeführt. Die Funktionalität aller Oberflächen konnte gezeigt werden, und das Verhältnis von Signal zu aufgebrachter Konzentration, sowie die Detektionslimits und Variations-Koeffizienten wurden analysiert. Weiterhin wurden neue Konzepte zur Herstellung der Oberflächenkopplungschemie wie PEG- Epoxy-Oberflächen und Dendrimer-Oberflächen untersucht und verbesserte Eigenschaften festgestellt. Optimale Oberflächenkopplungschemien wurden erläutert und im Hinblick auf die Anforderungen von Protein- und Antikörper- Mikroarrays diskutiert. Auf der Basis der Oberflächenoptimierung wurde weiterhin eine neue Technologie zur multiplexen Analyse von Substanzen auf Mikroarrays entwickelt, da es mit konventionellen Mikroarrays, mikrofluidischen Systemen und Nanowell-Chips entweder nicht möglich ist, gleichzeitig mehrere Analyte auf verschiedenen Bindern zu testen, oder weil hierfür komplizierte Apparaturen zur Leitung des Flüssigkeitsstroms oder zur Herstellung der Nanowells benötigt werden. In dem neuen Ansatz wurden multiplexe Immunoassays auf Mikroarray-Oberflächen ohne Vertiefungen mit Hilfe von konventionellen Spotting-Robotern durchgeführt. Das Verfahren, benannt �Multiple Spotting Technique� (MIST), umfasst hierbei die Immobilisierung des Binders auf einer Oberfläche und den anschließenden Transfer des Analyten mit Hilfe der gleichen Roboter auf die gleiche Stelle des Mikroarrays und somit auf den immobiliserten Binder. Da der Analyt sich hierbei in einem hygroskopischen Puffer befindet, entsteht ein Mikroreaktionsvolumen, in welchem der Analyt ohne zusätzliche Inkubationszeiten vom Binder gebunden wurde. Die Durchführbarkeit des Konzepts konnte durch den Transfer von Verdünnungsreihen monoklonaler und polyklonaler Antikörper auf deren immobiliserte Antigene und die anschließende Detektion der spezifischen Antikörper-Antigen Komplexe gezeigt werden. Hierbei wurden Detektionslimits von 400 Zeptomol (240.000 Antikörpermoleküle) gemessen. Die Spezifität, sowie die Kompatibilität zu gängigen Mikroarray-Techniken, wie der Gesamtinkubation, wurden durch die Aufbringung einer äquimolaren Antikörpermischung auf ein Antigen und anschließenden Gesamtinkubation mit markierten Sekundärantikörpern gezeigt, welches zur spezifischen Bildung von Antikörper-Antigen-Komplexen führte. Der gleiche Ansatz wurde auch zur Untersuchung von rekombinanten Antikörperpools von �Phage Display�-Selektionen angewandt. Während die eigentliche Selektion von rekombinanten Antikörpern mittlerweile automatisiert wurde, stellt die anschließende Identifikation positiver Binder bis heute noch einen großen Arbeitsaufwand dar. In dem neuen Ansatz werden die Antikörperfragmente-produzierenden Zellen in einem einzigen Inokulations- und Induktionsschritt im 384er Maßstab kultiviert und anschließend mit Hilfe der Multiple Spotting Technique auf die Antigene aufgebracht. Gleichzeitig wurden alle Antikörperfragmente auf Kreuzreaktivität mit Milchpulver untersucht, wodurch unspezifische Binder identifiziert werden konnten. Ein entscheidender Vorteil der MIST war hierbei, dass zusätzliche Inkubationszeiten durch die eingeschränkten Diffusionsmöglichkeiten innerhalb der Reaktionseinheiten ausgelassen werden konnten. Eine solche Untersuchung mit Hilfe von Mikroarrays war bisher nicht möglich, da die scFv's ohne Funktionsverlust nicht immobilisiert werden konnten. Der Vergleich des neuen Verfahrens mit ELISA zeigte, dass der MIST-basierte Ansatz schneller vergleichbare Sensitivitäten mit geringerem Antigenverbrauch lieferte. Weiterhin kann der neuartige Ansatz in die bestehende Automatisierung integriert werden, so dass eine schnellere Produktion von spezifischen rekombinanten Antikörpern möglich ist. ..

    Generation of High Density Protein Microarrays by Cell-free in Situ

    No full text

    Next generation of protein microarray support materials: Evaluation for protein and antibody microarray applications

    No full text
    The performance of protein and antibody microarrays is dependent on various factors, one of which is the use of an appropriate microarray surface for the immobilisation of either protein or antibody samples. We have investigated the properties of seven new surfaces in the context of both protein and antibody microarray technology. We have demonstrated the functionality of all new slide coatings and investigated the mean signal to spotted concentration ratio, determined detection limits and calculated coefficients of variation. Moreover, new concepts for slide coatings such as dendrimer and poly(ethylene glycol)-epoxy slides were evaluated and improved qualities of novel slide surfaces were observed. Optimal slide coatings for antibody and protein chips were proposed and the requirements for both technologies were discussed
    corecore