19 research outputs found

    Role of the tricuspid regurgitation after mitraclip and transcatheter aortic valve implantation: a systematic review and meta-analysis

    Get PDF
    Treatment of tricuspid regurgitation (TR) is common after surgery for mitral and/or aortic valves. The prognostic role of moderate to severe TR in patients undergoing mitraclip or transcatheter aortic valve implantation (TAVI) is not well-defined. Thus, the aim of this article is to perform a systematic review and meta-analysis of articles valuing the prognostic role of TR for patients undergoing mitraclip and TAVI

    Incremental value of contrast myocardial perfusion to detect intermediate versus severe coronary artery stenosis during stress-echocardiography

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We aimed to compare the incremental value of contrast myocardial perfusion imaging (MPI) for the detection of intermediate versus severe coronary artery stenosis during dipyridamole-atropine echocardiography (DASE).</p> <p>Wall motion (WM) assessment during stress-echocardiography demonstrates suboptimal sensitivity to detect coronary artery disease (CAD), particularly in patients with isolated intermediate (50%-70%) coronary stenosis.</p> <p>Methods</p> <p>We performed DASE with MPI in 150 patients with a suspected chest pain syndrome who were given clinical indication to coronary angiography.</p> <p>Results and discussion</p> <p>When CAD was defined as the presence of a ≄50% stenosis, the addition of MPI increased sensitivity (+30%) and decreased specificity (-14%), with a final increase in total diagnostic accuracy (+16%, p < 0.001). The addition of MPI data substantially increased the sensitivity to detect patients with isolated intermediate stenosis from 37% to 98% (p < 0.001); the incremental sensitivity was much lower in patients with severe stenosis, from 85% to 96% (p < 0.05), at the expense of a higher decrease in specificity and a final decrease in total diagnostic accuracy (-18%, p < 0.001).</p> <p>Conclusions</p> <p>The addition of MPI on top of WM analysis during DASE increases the diagnostic sensitivity to detect obstructive CAD, whatever its definition (≄50% or > 70% stenosis), but it is mainly driven by the sensitivity increase in the intermediate group (50%-70% stenosis).</p> <p>The total diagnostic accuracy increased only when defining CAD as ≄50% stenosis, since in patients with severe stenosis (> 70%) the decrease in specificity is not counterbalanced by the minor sensitivity increase.</p

    Predicting needlestick and sharps injuries in nursing students: Development of the SNNIP scale

    Get PDF
    © 2020 The Authors. Nursing Open published by John Wiley & Sons Ltd. Aim: To develop an instrument to investigate knowledge and predictive factors of needlestick and sharps injuries (NSIs) in nursing students during clinical placements. Design: Instrument development and cross-sectional study for psychometric testing. Methods: A self-administered instrument including demographic data, injury epidemiology and predictive factors of NSIs was developed between October 2018–January 2019. Content validity was assessed by a panel of experts. The instrument's factor structure and discriminant validity were explored using principal components analysis. The STROBE guidelines were followed. Results: Evidence of content validity was found (S-CVI 0.75; I-CVI 0.50–1.00). A three-factor structure was shown by exploratory factor analysis. Of the 238 participants, 39% had been injured at least once, of which 67.3% in the second year. Higher perceptions of “personal exposure” (4.06, SD 3.78) were reported by third-year students. Higher scores for “perceived benefits” of preventive behaviours (13.6, SD 1.46) were reported by second-year students

    Predicting needlestick and sharps injuries in nursing students: Development of the SNNIP scale

    Get PDF

    Safety of contrast flash-replenishment stress echocardiography in 500 patients with a chest pain episode of undetermined origin within the last 5 days

    No full text
    Safety concerns regarding the use of echo-contrast agents during baseline and SE in patients with recent chest pain have been raised. The purpose of the present study was to provide evidence regarding the safety of flash-replenishment contrast dipyridamole-atropine echocardiography (DASE) in such patients. Five hundred consecutive individuals who presented to the Emergency Department with chest pain, normal electrocardiograms (ECG) and troponin I were selected based on a less than 5 days interval between chest pain episode and performance of contrast flash-replenishment DASE. Analysis of myocardial perfusion with SonoVue(C) infusion after dipyridamole was routinely added on top of standard wall motion assessment during DASE. Adverse events (AEs) were reported according to standardized terminology and then compared with a historical control group in which contrast was not used. No deaths, myocardial infarctions, sustained arrhythmias, or any other life-threatening events were observed. Adverse events were not significantly different between the study group and the control group. In the selected subgroup of patients (n = 149) who underwent coronary angiography, accuracy of DASE with additional perfusion assessment was higher (88%, 95% C.I. 83-93%) than without (72%, 95% C.I. 65-79%). DASE with SonoVue(C) infusion for myocardial perfusion assessment was exceptionally safe even when routinely performed within the first 5 days following a chest pain episode of undetermined origin in subjects without ECG and troponin abnormalities

    Contrast Stress-Echocardiography Predicts Cardiac Events in Patients with Suspected Acute Coronary Syndrome but Nondiagnostic Electrocardiogram and Normal 12-Hour Troponin

    No full text
    BACKGROUND: No large study has demonstrated that any stress test can risk-stratify future hard cardiac events (cardiac death or myocardial infarction) in patients with suspected acute coronary syndromes (ACS), nondiagnostic electrocardiographic (ECG) findings, and normal troponin levels. The aim of this study was to test the hypothesis that combined contrast wall motion and myocardial perfusion echocardiographic assessment (cMCE) during stress echocardiography can predict long-term hard cardiac events in patients with suspected ACS, nondiagnostic ECG findings, and normal troponin. METHODS: A total of 545 patients referred for contrast stress echocardiography from the emergency department for suspected ACS but nondiagnostic ECG findings and normal troponin levels at 12 hours were followed up for cardiac events. Patients underwent dipyridamole-atropine echocardiography with adjunctive myocardial perfusion imaging using a commercially available ultrasound contrast medium (SonoVue). RESULTS: During a median follow-up period of 12 months, 25 cardiac events (4.6%) occurred (no deaths, 12 nonfatal myocardial infarctions, 13 episodes of unstable angina). Abnormal findings on cMCE were the most significant predictor of both hard cardiac events (hazard ratio, 22.8; 95% confidence interval, 2.9-176.7) and the combined (cardiac death, myocardial infarction, or unstable angina requiring revascularization) end point (hazard ratio, 10.7; 95% confidence interval,3.7-31.3). The inclusion of the cMCE variable significantly improved multivariate models, determining lower Akaike information criterion values and higher discrimination ability. CONCLUSIONS: cMCE during contrast stress echocardiography provided independent information for predicting hard and combined cardiac events beyond that predicted by stress wall motion abnormalities in patients with suspected ACS, nondiagnostic ECG findings, and normal troponin levels.-

    How new imaging techniques can aid in defining the cardiovascular profile of the high-risk patient

    Get PDF
    Cardiovascular prevention has been developed in the last eight years producing an ever increasing amount of data requiring frequent updating. Studies using angiography to determine change in coronary obstruction have indicated progression, stabilization, or regression of coronary lesions associated with changes in plasma lipids and lipoproteins. Moreover, the guidelines on arterial hypertension published in 2007 listed the risk factors affecting prognosis but even by 2009 an update modified not only the list of risks, but even the philosophy behind the thought process which introduced as essential element in the prognosis of hypertension the ascertained existence of a damaged organ. Thus, the documentation of atherosclerotic vascular disease (plaques) and the quantification of its extension in the arterial tree became a determinant in the definition of cardiovascular risk. Magnetic Resonance (MRI) and coronary computed tomography (coro CT) applied to the heart and large vessels are the most promising methods

    Performance of Synthetic Extracellular Volume Fraction in Different Cardiac Phenotypes From a Prospective Cohort of Patients Referred for Cardiac Magnetic Resonance

    No full text
    Background A synthetic myocardial extracellular volume fraction (sECV) can be obtained without blood hematocrit (Hct) by using the linear relationship between Hct and the longitudinal relaxation time of blood. Concerns have been raised about the widespread clinical application of this approach. Purpose To assess the relationship between measured ECV (m-ECV) and sECV, using both a published model and a locally derived one. Study Type Single-center, prospective. Field Strength/Sequence A 1.5 T/modified Look Locker (MOLLI) sequence. Subjects Fifty-two healthy subjects and 113 patients (76 with and 37 without a hypertrophic cardiac phenotype). Assessment Three ECV values were obtained for each patient: 1) measured ECV (m-ECV), using Hct from a venous blood sample; 2) Fent-synthetic ECV (F-sECV), using the equation proposed by Fent et al; and 3) Local-synthetic ECV (L-sECV), using the equation obtained from a local derivation cohort comprising 83 subjects. Statistical Tests Shapiro-Wilk test, analysis of variance, Kruskal Wallis test, Pearson correlation, Bland-Altman analysis, univariate and multivariable regression analysis. Results In the validation cohort (N = 82), Bland-Altmann analysis revealed an excellent agreement between m-ECV and L-sECV with a statistically insignificant bias (-0.1%, limits of agreement: -2.8% and 2.6%; P = 0.528), while in the overall population (N = 165), the mean bias between m-ECV and F-sECV was small but significant (1.2%, limits of agreement: -1.5% and 3.9%, P &lt; 0.05). F-sECV bias was significantly higher for measured Hct (m-Hct) values &lt;0.372 (2.3% vs. 1.0%, P &lt; 0.05). Among the phenotype subgroups, amyloidotic patients showed a higher bias compared to others, both with F-sECV and L-sECV (2.3% vs. 1.1%, P &lt; 0.05 and 1.1% vs. 0.2%, P &lt; 0.05, respectively). Data Conclusion Although synthetic ECV performs well in an external cohort, the use of a local formula further improves the accuracy of ECV estimate over a broad spectrum of cardiac phenotypes. Local sECV performs better for a wider range of Hct values, compared to the published model. Amyloidosis is the only group associated with a lower accuracy. Level of Evidence 5 Technical Efficacy Stage
    corecore