443 research outputs found
Interview with Auctioneer John \u27Red\u27 Shaw
John Shaw discusses growing up on a farm and being in 4H, and getting involved in the auction business; specifically getting involved with agriculture sales. He also discusses how the new buyers are buying bigger sections of land and have bigger equipment, they are less likely to be small, family farms. He says the biggest change he\u27s noticed in his time is that the farms are becoming bigger and the owners are not young people, because it is so expensive to start a farm.https://digital.kenyon.edu/ffp_interviews/1038/thumbnail.jp
Review of Non-destructive Testing (NDT) Techniques and their applicability to thick walled composites
A tier 1 automotive supplier has developed a novel and unique kinetic energy recovery storage system for both retro-fitting and OEM application for public transport systems where periodic stop start behaviour is paramount. A major component of the system is a composite flywheel spinning at up to 36,000 rpm (600 Hz). Material soundness is an essential requirement of the flywheel to ensure failure does not occur. The component is particularly thick for a composite being up to 30 mm cross section in some places. The geometry, scale and material make-up pose some challenges for conventional NDT systems. Damage can arise in composite materials during material processing, fabrication of the component or in-service activities among which delamination, cracks and porosity are the most common defects. A number of non-destructive testing (NDT) techniques are effective in testing components for defects without damaging the component. NDT techniques like Ultrasonic Testing, X-Ray, Radiography, Thermography, Eddy current and Acoustic Emission are current techniques for various testing applications. Each of these techniques uses different principles to look into the material for defects. However, the geometry, physical and material properties of the component being tested are important factors in the applicability of a technique. This paper reviews these NDT techniques and compares them in terms of characteristics and applicability to composite parts
Regulatory Requirements for Staphylococcus aureus Nitric Oxide Resistance
ABSTRACT The ability of Staphylococcus aureus to resist host innate immunity augments the severity and pervasiveness of its pathogenesis. Nitric oxide (NO˙) is an innate immune radical that is critical for the efficient clearance of a wide range of microbial pathogens. Exposure of microbes to NO˙ typically results in growth inhibition and induction of stress regulons. S. aureus , however, induces a metabolic state in response to NO˙ that allows for continued replication and precludes stress regulon induction. The regulatory factors mediating this distinctive response remain largely undefined. Here, we employ a targeted transposon screen and transcriptomics to identify and characterize five regulons essential for NO˙ resistance in S. aureus : three virulence regulons not formerly associated with NO˙ resistance, SarA, CodY, and Rot, as well as two regulons with established roles, Fur and SrrAB. We provide new insights into the contributions of Fur and SrrAB during NO˙ stress and show that the S. aureus Δ sarA mutant, the most sensitive of the newly identified mutants, exhibits metabolic dysfunction and widespread transcriptional dysregulation following NO˙ exposure. Altogether, our results broadly characterize the regulatory requirements for NO˙ resistance in S. aureus and suggest an intriguing overlap between the regulation of NO˙ resistance and virulence in this well-adapted human pathogen. IMPORTANCE The prolific human pathogen Staphylococcus aureus is uniquely capable of resisting the antimicrobial radical nitric oxide (NO˙), a crucial component of the innate immune response. However, a complete understanding of how S. aureus regulates an effective response to NO˙ is lacking. Here, we implicate three central virulence regulators, SarA, CodY, and Rot, as major players in the S. aureus NO˙ response. Additionally, we elaborate on the contribution of two regulators, SrrAB and Fur, already known to play a crucial role in S. aureus NO˙ resistance. Our study sheds light on a unique facet of S. aureus pathogenicity and demonstrates that the transcriptional response of S. aureus to NO˙ is highly pleiotropic and intrinsically tied to metabolism and virulence regulation
A Comparative Integrated Geophysical Study of Horseshoe Chimney Cave, Colorado Bend State Park, Texas
An integrated geophysical study was performed over a known cave in Colorado Bend State Park (CBSP), Texas, where shallow karst features are common within the Ellenberger Limestone. Geophysical survey such as microgravity, ground penetrating radar (GPR), direct current (DC) resistivity, capacitively coupled (CC) resistivity, induced polarization (IP) and ground conductivity (GC) measurements were performed in an effort to distinguish which geophysical method worked most effectively and efficiently in detecting the presence of subsurface voids, caves and collapsed features. Horseshoe Chimney Cave (HCC), which is part of a larger network of cave systems, provides a good control environment for this research. A 50 x 50 meter grid, with 5 m spaced traverses was positioned around the entrance to HCC. Geophysical techniques listed above were used to collect geophysical data which were processed with the aid of commercial software packages. A traditional cave survey was conducted after geophysical data collection, to avoid any bias in initial data collection. The survey of the cave also provided ground truthing. Results indicate the microgravity followed by CC resistivity techniques worked most efficiently and were most cost effective, while the other methods showed varying levels of effectiveness
Bone turnover and metabolite responses to exercise in people with and without long-duration type 1 diabetes: a case-control study
INTRODUCTION: Exercise acutely alters markers of bone resorption and formation. As risk of fracture is increased in patients with type 1 diabetes, understanding if exercise-induced bone turnover is affected within this population is prudent. We assessed bone turnover responses to acute exercise in individuals with long-duration type 1 diabetes and matched controls. RESEARCH DESIGN AND METHODS: Participants with type 1 diabetes (n=15; age: 38.7±13.3; glycosylated hemoglobin: 60.5±6.7 mmol/mol; diabetes duration: 19.3±11.4 years) and age-matched, fitness-matched, and body mass index-matched controls (n=15) completed 45 min of incline walking (60% peak oxygen uptake). Blood samples were collected at baseline and immediately, 30 min, and 60 min postexercise. Markers of bone resorption (β-C-terminal cross-linked telopeptide of type 1 collagen, β-CTx) and formation (procollagen type-1 amino-terminal propeptide, P1NP), parathyroid hormone (PTH), phosphate, and calcium (albumin-adjusted and ionized) were measured. Data (mean±SD) were analyzed by a mixed-model analysis of variance. RESULTS: Baseline concentrations of P1NP and β-CTx were comparable between participants with type 1 diabetes and controls. P1NP did not change with exercise (p=0.20) but β-CTx decreased (p0.39). Participants with type 1 diabetes had reduced albumin and ionized calcium at all sample points (p<0.01). CONCLUSIONS: Following exercise, participants with type 1 diabetes displayed similar time-course changes in markers of bone formation and associated metabolites, but an attenuated suppression in bone resorption. The reduced albumin and ionized calcium may have implications for future bone health. Further investigation of the interactions between type 1 diabetes, differing modalities and intensities of exercise, and bone health is warranted
Diagnostic accuracy of the Enferplex Bovine TB antibody test using individual milk samples from cattle
Bovine tuberculosis is usually diagnosed using tuberculin skin tests or at post-mortem. Recently, we have developed a serological test for bovine tuberculosis in cattle which shows a high degree of accuracy using serum samples. Here, we have assessed the performance of the test using individual bovine milk samples. The diagnostic specificity estimate using the high sensitivity setting of the test was 99.7% (95% CI: 99.2-99.9). This estimate was not altered significantly by tuberculin boosting. The relative sensitivity estimates of the test using the high sensitivity setting in milk samples from comparative skin test positive animals was 90.8% (95% CI: 87.1-93.6) with boosting. In animals with lesions, the relative sensitivity was 96.0% (95% CI: 89.6-98.7). Analysis of paired serum and milk samples from skin test positive animals showed correlation coefficients ranging from 0.756-0.955 for individual antigens used in the test. Kappa analysis indicated almost perfect agreement between serum and milk results, while McNemar marginal homogeneity analysis showed no statistically significant differences between the two media. The positive and negative likelihood ratio were 347.8 (95% CI: 112.3-1077.5) and 0.092 (95% CI: 0.07-0.13) respectively for boosted samples from skin test positive animals. The results show that the test has high sensitivity and specificity in individual milk samples and thus milk samples could be used for the diagnosis of bovine tuberculosis.</p
Diagnostic accuracy of the Enferplex Bovine Tuberculosis antibody test in cattle sera
Bovine tuberculosis is a contagious bacterial disease of worldwide economic, zoonotic and welfare importance caused mainly by Mycobacterium bovis infection. Current regulatory diagnostic methods lack sensitivity and require improvement. We have developed a multiplex serological test for bovine tuberculosis and here we provide an estimate of the diagnostic accuracy of the test in cattle. Positive and negative reference serum samples were obtained from animals from Europe and the United States of America. The diagnostic specificity estimate was 98.4% and 99.7% using high sensitivity and high specificity settings of the test respectively. Tuberculin boosting did not affect the overall specificity estimate. The diagnostic sensitivity in samples from Mycobacterium bovis culture positive animals following tuberculin boosting was 93.9%.The relative sensitivity following boosting in tuberculin test positive, lesion positive animals and interferon gamma test positive, lesion positive animals was 97.2% and 96.9% respectively. In tuberculin test negative, lesion positive animals and in interferon gamma test negative, lesion positive animals, the relative sensitivity following tuberculin boosting was 88.2% and 83.6% respectively. The results show that the test has high diagnostic sensitivity and specificity and can detect infected animals that are missed by tuberculin and interferon gamma testing
Detection of the gas–liquid two-phase flow regimes using non-intrusive microwave cylindrical cavity sensor
Gas–liquid two-phase flow phenomenon occurs in various engineering applications and the measurement of it is important. A microwave sensor in the form of a cylindrical cavity has been designed to operate between 5 and 5.7 GHz. The aim is to analyse a two phase gas–liquid flow regime in a pipeline. LabVIEW software is utilised to capture the data, process them and display the results in real time. The results have shown that the microwave sensor has successfully detected the two-phase flow regimes in both the static and dynamic flow environments with reasonable accuracy. The study has also shown the independence of the technique and its accuracy to the temperature change (28–83 °C). Several flow regimes of the gas–liquid two-phase flow have been discussed. The system is also able to detect the stratified, wavy, elongated bubbles and homogeneous flow regimes
- …