660 research outputs found

    Enhanced drag in pipe turbulent flow by an aqueous electrolyte: an electroviscous effect

    Get PDF
    Drag enhancement is reported for turbulent pipe flow of aqueous electrolyte solutions. No electroviscous effect was obtained with laminar flow. Nor was any unusual pressure drop observed for laminar or turbulent flow of non-electrolyte aqueous solutions such as sugar. An electroviscous theory was advanced that predicted the drag enhancement for a 1/1 electrolyte solution. The theory depended on consideration of Debye length

    Mechanical Entanglement via Detuned Parametric Amplification

    Full text link
    We propose two schemes to generate entanglement between a pair of mechanical oscillators using parametric amplification. In contrast to existing parametric drive-based protocols, both schemes operate in the steady-state. Using a detuned parametric drive to maintain equilibrium and to couple orthogonal quadratures, our approach can be viewed as a two-mode extension of previous proposals for parametric squeezing. We find that robust steady-state entanglement is possible for matched oscillators with well-controlled coupling. In addition, one of the proposed schemes is robust to differences in the damping rates of the two oscillators.Comment: 13 pages, 2 figure

    Detuned Mechanical Parametric Amplification as a Quantum Non-Demolition Measurement

    Full text link
    Recently it has been demonstrated that the combination of weak-continuous position detection with detuned parametric driving can lead to significant steady-state mechanical squeezing, far beyond the 3 dB limit normally associated with parametric driving. In this work, we show the close connection between this detuned scheme and quantum non-demolition (QND) measurement of a single mechanical quadrature. In particular, we show that applying an experimentally realistic detuned parametric drive to a cavity optomechanical system allows one to effectively realize a QND measurement despite being in the bad-cavity limit. In the limit of strong squeezing, we show that this scheme offers significant advantages over standard backaction evasion, not only by allowing operation in the weak measurement and low efficiency regimes, but also in terms of the purity of the mechanical state.Comment: 17 pages, 2 figure

    Minimum requirements for feedback enhanced force sensing

    Full text link
    The problem of estimating an unknown force driving a linear oscillator is revisited. When using linear measurement, feedback is often cited as a mechanism to enhance bandwidth or sensitivity. We show that as long as the oscillator dynamics are known, there exists a real-time estimation strategy that reproduces the same measurement record as any arbitrary feedback protocol. Consequently some form of nonlinearity is required to gain any advantage beyond estimation alone. This result holds true in both quantum and classical systems, with non-stationary forces and feedback, and in the general case of non-Gaussian and correlated noise. Recently, feedback enhanced incoherent force sensing has been demonstrated [Nat. Nano. \textbf{7}, 509 (2012)], with the enhancement attributed to a feedback induced modification of the mechanical susceptibility. As a proof-of-principle we experimentally reproduce this result through straightforward filtering.Comment: 5 pages + 2 pages of Supplementary Informatio

    Adaptive homodyne measurement of optical phase

    Get PDF
    We present an experimental demonstration of the power of real-time feedback in quantum metrology, confirming a theoretical prediction by Wiseman regarding the superior performance of an adaptive homodyne technique for single-shot measurement of optical phase. For phase measurements performed on weak coherent states with no prior knowledge of the signal phase, we show that the variance of adaptive homodyne estimation approaches closer to the fundamental quantum uncertainty limit than any previously demonstrated technique. Our results underscore the importance of real-time feedback for reaching quantum performance limits in coherent telecommunication, precision measurement and information processing.Comment: RevTex4, color PDF figures (separate files), submitted to PR

    Continuous quantum error correction via quantum feedback control

    Get PDF
    We describe a protocol for continuously protecting unknown quantum states from decoherence that incorporates design principles from both quantum error correction and quantum feedback control. Our protocol uses continuous measurements and Hamiltonian operations, which are weaker control tools than are typically assumed for quantum error correction. We develop a cost function appropriate for unknown quantum states and use it to optimize our state-estimate feedback. Using Monte Carlo simulations, we study our protocol for the three-qubit bit-flip code in detail and demonstrate that it can improve the fidelity of quantum states beyond what is achievable using quantum error correction when the time between quantum error correction cycles is limited.Comment: 12 pages, 6 figures, REVTeX; references fixe

    Application of Room Temperature Ionic Liquids to the Development of Electrochemical Lipase Biosensing Systems for Water-Insoluble Analytes

    Get PDF
    Biosensors have been prepared by modification of glassy carbon electrodes with functionalised multiwalled carbon nanotubes (MWCNT) dispersed in the room temperature ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethane)sulfonimide (BmimNTF2) and with lipase cross-linked with glutaraldehyde. The biosensor was applied to the determination of olive oil triglycerides by cyclic voltammetry. A phosphate buffer (pH 7.0) / BmimNO3 mixture is a better electrolyte than aqueous buffer alone. The response signal in the buffer-BmimNO3 mixture was found to increase with the number of cycles until a constant current was achieved. The calibration curve obtained exhibited a sigmoid-shape and a fourparameter model was used to fit the data which gave a limit of detection of 0.11 ÎŒg mL−1. Close inspection of such calibration curves showed two distinct linear regions indicating changes in the mechanism of the electrochemical response. Overall, the oxidative analytical response was found to be due to phenolic compounds present in the olive oil, released in the presence of lipase, rather than due to triglycerides per se. It was also found that there were no interferences from either cholesterol or glycerol. A possible mechanism of olive oil determination at a MWCNT-BmimNTF2/Lip biosensor is proposed
    • 

    corecore