26 research outputs found

    Very low noise AC/DC power supply systems for large detector arrays

    Get PDF
    In this work, we present the first part of the power supply system for the CUORE and LUCIFER arrays of bolometric detectors. For CUORE, it consists of AC/DC commercial power supplies (0–60 V output) followed by custom DC/DC modules (48 V input, ±5 V to ±13.5 V outputs). Each module has 3 floating and independently configurable output voltages. In LUCIFER, the AC/DC + DC/DC stages are combined into a commercial medium-power AC/DC source. At the outputs of both setups, we introduced filters with the aim of lowering the noise and to protect the following stages from high voltage spikes that can be generated by the energy stored in the cables after the release of accidental short circuits. Output noise is very low, as required: in the 100 MHz bandwidth the RMS level is about 37 μVRMS (CUORE setup) and 90 μVRMS (LUCIFER setup) at a load of 7 A, with a negligible dependence on the load current. Even more importantly, high frequency switching disturbances are almost completely suppressed. The efficiency of both systems is above 85%. Both systems are completely programmable and monitored via CAN bus (optically coupled)

    The STRIP instrument of the Large Scale Polarization Explorer: microwave eyes to map the Galactic polarized foregrounds

    Get PDF
    In this paper we discuss the latest developments of the STRIP instrument of the "Large Scale Polarization Explorer" (LSPE) experiment. LSPE is a novel project that combines ground-based (STRIP) and balloon-borne (SWIPE) polarization measurements of the microwave sky on large angular scales to attempt a detection of the "B-modes" of the Cosmic Microwave Background polarization. STRIP will observe approximately 25% of the Northern sky from the "Observatorio del Teide" in Tenerife, using an array of forty-nine coherent polarimeters at 43 GHz, coupled to a 1.5 m fully rotating crossed-Dragone telescope. A second frequency channel with six-elements at 95 GHz will be exploited as an atmospheric monitor. At present, most of the hardware of the STRIP instrument has been developed and tested at sub-system level. System-level characterization, starting in July 2018, will lead STRIP to be shipped and installed at the observation site within the end of the year. The on-site verification and calibration of the whole instrument will prepare STRIP for a 2-years campaign for the observation of the CMB polarization.Comment: 17 pages, 15 figures, proceedings of the SPIE Astronomical Telescopes + Instrumentation conference "Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX", on June 15th, 2018, Austin (TX

    Sheets of vertically aligned BaTiO<sub>3</sub> nanotubes reduce cell proliferation but not viability of NIH-3T3 cells

    Get PDF
    All biomaterials initiate a tissue response when implanted in living tissues. Ultimately this reaction causes fibrous encapsulation and hence isolation of the material, leading to failure of the intended therapeutic effect of the implant. There has been extensive bioengineering research aimed at overcoming or delaying the onset of encapsulation. Nanotechnology has the potential to address this problem by virtue of the ability of some nanomaterials to modulate interactions with cells, thereby inducing specific biological responses to implanted foreign materials. To this effect in the present study, we have characterised the growth of fibroblasts on nano-structured sheets constituted by BaTiO3, a material extensively used in biomedical applications. We found that sheets of vertically aligned BaTiO3 nanotubes inhibit cell cycle progression - without impairing cell viability - of NIH-3T3 fibroblast cells. We postulate that the 3D organization of the material surface acts by increasing the availability of adhesion sites, promoting cell attachment and inhibition of cell proliferation. This finding could be of relevance for biomedical applications designed to prevent or minimize fibrous encasement by uncontrolled proliferation of fibroblastic cells with loss of material-tissue interface underpinning long-term function of implants

    Evaluation of the safety and efficacy of the organic acids lactic and acetic acids to reduce microbiological surface contamination on pork carcasses and pork cuts

    Get PDF
    Studies evaluating the safety and efficacy of lactic and acetic acids to reduce microbiological surface contamination on pork carcasses pre-chill and pork meat cuts post-chill were assessed. Lactic acid treatments consisted of 2–5% solutions at temperatures of up to 80°C applied to carcasses by spraying or up to 55°C applied on cuts by spraying or dipping. Acetic acid treatments consisted of 2–4% solutions at temperatures of up to 40°C applied on carcasses by spraying or on cuts by spraying or dipping. The maximum treatment duration was 30 s. The Panel concluded that: [1] the treatments are of no safety concern, provided that the substances comply with the European Union specifications for food additives; [2] spraying of pork carcasses pre-chill with lactic acid was efficacious compared to untreated control, but based on the available data, the Panel could not conclude whether lactic acid was more efficacious than water treatment when spraying of pork carcasses pre-chill or pork meat cuts post-chill. The Panel concluded that dipping of pork meat cuts post-chill in lactic acid was more efficacious than water treatment. However, it could not conclude on the efficacy of acetic acid treatment of pork carcasses pre-chill and/or pork meat cuts post-chill; [3] the potential selection and emergence of bacteria with reduced susceptibility to biocides and/or resistance to therapeutic antimicrobials linked to the use of the substances is unlikely as long as Good Hygienic Practices are implemented; and [4] the release of both organic acids is not of concern for the environment, assuming that wastewaters released by the slaughterhouses are treated, if necessary, to counter the potentially low pH caused by lactic or acetic acid, in compliance with local rules.info:eu-repo/semantics/publishedVersio

    Detection chain and electronic readout of the QUBIC instrument

    Get PDF
    The Q and U Bolometric Interferometer for Cosmology (QUBIC) Technical Demonstrator (TD) aiming to shows the feasibility of the combination of interferometry and bolometric detection. The electronic readout system is based on an array of 128 NbSi Transition Edge Sensors cooled at 350mK readout with 128 SQUIDs at 1K controlled and amplified by an Application Specific Integrated Circuit at 40K. This readout design allows a 128:1 Time Domain Multiplexing. We report the design and the performance of the detection chain in this paper. The technological demonstrator unwent a campaign of test in the lab. Evaluation of the QUBIC bolometers and readout electronics includes the measurement of I-V curves, time constant and the Noise Equivalent Power. Currently the mean Noise Equivalent Power is ~ 2 x 10⁻¹⁶ W/√Hz

    Extensive assessment of metrics on RNA secondary structures and relative ensembles

    No full text
    The ability to properly compare RNA secondary conformations is of prominent importance in many RNA structural investigations, and particularly in the study of non-coding RNAs (ncRNAs). Several different metrics have been proposed to catch topological dissimilarities between RNA secondary structures, but so far specific metric features have not been assessed yet against extensive datasets. The choice of proper metrics is also crucial for the characterization of structural ensembles, so to be able to proficiently analyze them. The current availability of large ncRNA databases has made it possible to perform an extensive comparison of different metrics. Correlation analysis has uncovered the relative descriptive power of such metrics, providing indications on their possible practical use in different contexts

    EFSA's compendium of botanicals

    No full text
    <p>EFSA’s Compendium of Botanicals is a database of botanicals that are reported to contain naturally occurring substances of possible concern for human health when present in food.</p> <p>The compendium is not intended to conclude on the safety or non-safety of the listed botanical species but to help with the safety assessment of botanicals and botanical preparations intended for use in food, including supplements, by facilitating hazard identification.</p> <p>The compendium does not list all bioactive substances present in a given botanical and their potential health effects, nor does it flag botanicals or botanical substances of possible concern for animal health when used as feed or feed additives. However, where adverse effects reported on animal health were found in the literature, they are reported in the compendium.</p> <p>Information provided by the Compendium:</p> <ul> <li>The <strong>Botanical Species</strong>. The taxonomy database “the Plant List” was taken as a reference. If not found in this database, or where the scientific name of the botanical was not officially accepted (“unresolved”), ARSGRIN was used. If still unsuccessful, the International Plant Name Index was consulted.</li> <li>The <strong>Family</strong>. In many cases, botanicals from a given family contain similar groups of compounds. Therefore, knowing the family name may provide indications of the possible presence of similar compounds in other species not included in the compendium. The Plant List database was used as the main source of information.</li> <li>The<strong> Plant Part</strong> in which the compounds of concern were reported to be present, or for which adverse effect(s) was reported without any identification of substances of concern.</li> <li>The <strong>Preparation, </strong>including essential oils, linked to the presence of a substance of possible concern or an adverse effect.</li> <li>The <strong>Substances or chemical groups of concern</strong> when they were identified. This compendium is intended for hazard identification, whereas risk assessment would require additional information on the concentration of the substance of possible concern in the product on the market, as well as the level of exposure of the consumer to this substance.</li> <li>The <strong>Effect Description</strong> found in the scientific literature when they could not be associated to any of the compound(s) of concern. The toxicity of the compound(s) of concern will be characterized in a next phase of development of the compendium.</li> <li>The <strong>Reference</strong> retrieved from literature searches for the data given, and/or standard reference textbooks providing monographs or more general scientific information for the botanicals considered.</li> </ul

    Experimental investigation on the mechanical behavior of polyurethane PICCs after long-term conservation in in vivo-like conditions

    No full text
    Introduction: In a previous paper, the authors investigated the mechanical behavior of several commercial polyurethane peripherally inserted central venous catheters (PICCs) in their 'brand new' condition. The present study represents a second step of the research activity and aims to investigate possible modifications of the PICC mechanical response, induced by long-term conservation in in vivo-like conditions, particularly when used to introduce oncologic drugs. Methods: Eight 5 Fr single-lumen catheters from as many different vendors, were examined. Several specimens were cut from each of them and kept in a bath at 37°C for 1, 2, 3 and 6 months. Two fluids were used to simulate in vivo-like conditions, i.e. ethanol and Ringer-lactate solutions, the first being chosen in order to reproduce a typical chemical environment of oncologic drugs. The test plan included swelling analyses, uniaxial tensile tests and dynamic mechanical thermal analysis (DMTA). Results and conclusions: All tested samples were chemically and mechanically stable in the studied conditions, as no significant weight variation was observed even after six months of immersion in ethanol solution. Uniaxial tensile tests confirmed such a response. For each PICC, very similar curves were obtained from samples tested after different immersion durations in the two fluid solutions, particularly for strains lower than 10%
    corecore