5 research outputs found

    TÉCNICAS DE ESCOVAÇÃO DENTÁRIA

    Get PDF
    Introduction: The mechanical removal of biofilm by flossing and brushing techniques from the dental surfaces should be individually applied to each patient in order to maintain the oral health. Objective: This study aimed at reviewing the literature on toothbrushing techniques, identify and describe them according to the oral health condition and also differentiate the step-by-step procedures and show the data in a synoptic table. Methodology: The search strategy used the descriptors “oral hygiene” or “tooth brushing” and “techniques” in three databases. Articles from the last twenty years published in Portuguese and available as full text were selected. The inclusion criteria considered purpose and indication of brushing technique; position, inclination and direction of brush bristles; type and duration of brush movement. Results: Forty-eight articles were found but only two of them described the tooth brushing technique. The exploratory analysis considered twenty-one technical documents. The descriptive analysis analysed twenty-three documents but two of them were discarded because they did not attend at least three inclusion criteria listed above. Conclusion: There was disagreement on the informations found, probably due to the scarcity of a technical document on this subject. Further studies must be done to describe the importance, the indication and the way of performing the toothbrushing techniques.Introducción: La extracción mecánica del biofilm de las superficies dentales mediante cepillado, asociada al uso de hilo dental, debe ser individualizada para cada paciente para mantener la salud bucal. Objetivo: el objetivo fue revisar la literatura sobre técnicas de cepillado dental, identificar y describir las técnicas encontradas en la literatura según el estado de salud bucal, diferenciar su ejecución paso a paso y presentar los datos en un cuadro sinóptico. Metodología: La estrategia de búsqueda utilizó los descriptores "higiene bucal" o "cepillado de dientes" y "técnicas" en tres bases de datos. La investigación ha reclutado artículos de los últimos veinte años publicados en portugués y disponibles en Internet como texto completo. Los criterios de inclusión observados fueron: objetivo e indicación de la técnica de cepillado; posición, inclinación y dirección de los bristers de cepillo; tipo y duración del movimiento del pincel. Resultados: Se encontraron cuarenta y ocho artículos, pero sólo dos describieron la técnica de cepillado de dientes. Veintiún documentos técnicos fueron incluidos en el análisis exploratorio. Veintitrés documentos fueron analizados en el análisis descriptivo, pero dos fueron excluidos porque no cumplían con el mínimo de tres criterios de inclusión. Conclusión: Hubo divergencia en la información encontrada en la literatura, posiblemente debido a la escasez de un documento técnico sobre el tema, y se necesitan más estudios para reforzar la importancia, indicación y modo de realización de las técnicas de cepillado dental.Introdução: A remoção mecânica do biofilme das superfícies dentárias pela escovação, associada ao uso do fio dental, deve ser individualizada para cada paciente a fim de manter a saúde bucal. Objetivo:  revisar a literatura sobre técnicas de escovação dentária, identificar e descrever as técnicas encontradas conforme a condição de saúde bucal, diferenciar o seu passo a passo de execução e apresentar os dados em quadro sinóptico. Metodologia: A estratégia de busca usou os descritores “higiene bucal” ou "escovação dentária" e "técnicas" em três bases de dados. A pesquisa recrutou artigos dos últimos vinte anos publicados em português e disponíveis na internet com o texto completo. Os critérios de inclusão observados foram: objetivo e indicação da técnica de escovação; posição, inclinação e sentido das cerdas da escova; tipo e duração do movimento da escova. Resultados: Quarenta e oito artigos foram encontrados, mas apenas dois descreveram a técnica de escovação dentária. Na análise exploratória foram incluídos vinte e um documentos técnicos. Na análise descritiva vinte e três documentos foram analisados, mas dois foram excluídos por não atenderem o mínimo de três critérios de inclusão. Conclusão: Houve divergência nas informações encontradas na literatura, possivelmente pela escassez de documento técnico sobre o assunto, sendo necessário mais estudos que reforcem a importância, a indicação e o modo de realização das técnicas de escovação dentária

    Influência do casquete (com ou sem contato cervical com a estrutura moldada) e da moldeira de estoque, para um único elastômero, sobre a precisão dimensional de troquéis de um gesso tipo IV

    No full text
    O objetivo no presente trabalho foi avaliar a fidelidade dimensional de troqueis de gesso tipo IV (Vel-Mix®), obtidos a partir de moldes de um único elastômero (Impregum® F), utilizando-se duas diferentes técnicas de moldagem (com casquete ou com moldeira de estoque). A fidelidade de cada troquel obtido foi avaliada através de uma coroa-padrão, a qual encaixava-se com alta precisão ao troquelpadrão, o qual era a estrutura original a ser moldada. Assim foram compostos os 4 seguintes grupos, com o aquecimento do molde não tendo sido efetuado apenas no primeiro deles: 1- do casquete de resina, sem contato com a porção cervical do troquel-padrão (Cstsa); 2- do casquete, também sem o referido contato (Cstca) ; 3- novamente do casquete, agora com contato (Cctca) e 4-. da moldeira de estoque perfurada (Mca). Com base nos resultados encontrados nas condições estabelecidas, após o respectivo tratamento estatístico, foi possível concluir que: 1 - o pior desempenho ocorreu com a moldeira perfurada, com um desajuste médio da ordem de 397, 70 micrometros; 2 - o casquete com toque e com aquecimento (desajuste médio de 85,37 micrometros) apresentou desempenho semelhante ao do casquete sem toque e sem aquecimento (desajuste médio de 102,38 micrometros) e 3 - o melhor desempenho ocorreu com o casquete sem toque e com aquecimento, com um desajuste médio de 0, 03 micrometros.The aim in this study was to evaluate the dimensional accuracy of dies made with a type IV stone (Vel-Mix®) dies, obtained from moulds of a sole elastomer (Impregum® F), by employing 2 different moulding techniques, with a shell or with a perforated stock tray. Stone dies accuracy was measured by means of a standard crown which could be accurately fitted to the standard die, the original structure to be moulded. In this way, the following 4 groups were stablished, with the mould heating not being done only in the first of them: 1- with the acrylic resin shell cervically not contacting the standard die; 2- with the refered shell but without that contact; 3- once more with the shell, again with that contact and 3- with the stock tray. Under the stablished conditions, after statistical treatment of results, the following conclusions could be drawn: 1- worst performance was presented by the stock tray, with a 397,70 µm mean inaccuracy; 2- the shell performance with cervical contact and heated (85,37 µm mean inaccuracy) was similar to that of it without contact and without heating (102,38 µm mean inaccuracy) and 3- better performance was presented by shell without contact and with heating, with a 0,03 µm mean inaccuracy

    Influência do casquete (com ou sem contato cervical com a estrutura moldada) e da moldeira de estoque, para um único elastômero, sobre a precisão dimensional de troquéis de um gesso tipo IV

    No full text
    O objetivo no presente trabalho foi avaliar a fidelidade dimensional de troqueis de gesso tipo IV (Vel-Mix®), obtidos a partir de moldes de um único elastômero (Impregum® F), utilizando-se duas diferentes técnicas de moldagem (com casquete ou com moldeira de estoque). A fidelidade de cada troquel obtido foi avaliada através de uma coroa-padrão, a qual encaixava-se com alta precisão ao troquelpadrão, o qual era a estrutura original a ser moldada. Assim foram compostos os 4 seguintes grupos, com o aquecimento do molde não tendo sido efetuado apenas no primeiro deles: 1- do casquete de resina, sem contato com a porção cervical do troquel-padrão (Cstsa); 2- do casquete, também sem o referido contato (Cstca) ; 3- novamente do casquete, agora com contato (Cctca) e 4-. da moldeira de estoque perfurada (Mca). Com base nos resultados encontrados nas condições estabelecidas, após o respectivo tratamento estatístico, foi possível concluir que: 1 - o pior desempenho ocorreu com a moldeira perfurada, com um desajuste médio da ordem de 397, 70 micrometros; 2 - o casquete com toque e com aquecimento (desajuste médio de 85,37 micrometros) apresentou desempenho semelhante ao do casquete sem toque e sem aquecimento (desajuste médio de 102,38 micrometros) e 3 - o melhor desempenho ocorreu com o casquete sem toque e com aquecimento, com um desajuste médio de 0, 03 micrometros.The aim in this study was to evaluate the dimensional accuracy of dies made with a type IV stone (Vel-Mix®) dies, obtained from moulds of a sole elastomer (Impregum® F), by employing 2 different moulding techniques, with a shell or with a perforated stock tray. Stone dies accuracy was measured by means of a standard crown which could be accurately fitted to the standard die, the original structure to be moulded. In this way, the following 4 groups were stablished, with the mould heating not being done only in the first of them: 1- with the acrylic resin shell cervically not contacting the standard die; 2- with the refered shell but without that contact; 3- once more with the shell, again with that contact and 3- with the stock tray. Under the stablished conditions, after statistical treatment of results, the following conclusions could be drawn: 1- worst performance was presented by the stock tray, with a 397,70 µm mean inaccuracy; 2- the shell performance with cervical contact and heated (85,37 µm mean inaccuracy) was similar to that of it without contact and without heating (102,38 µm mean inaccuracy) and 3- better performance was presented by shell without contact and with heating, with a 0,03 µm mean inaccuracy

    Effect of cervical relining of acrylic resin copings on the accuracy of stone dies obtained using a polyether impression material

    Get PDF
    The purpose of this study was to evaluate the accuracy of the respective dies after polyether elastomeric procedure in the presence or absence of cervical contact of the acrylic resin shell with the cervical region, establishing a comparison to dies obtained with stock trays. This study consisted of three groups with 10 specimens each: 1) acrylic copings without cervical contact, (cn); 2) acrylic copings with cervical contact (cc); 3) perforated stock tray, (st). The accuracy of the resulting dies was verified with the aid of a master crown, precisely fit to the master steel die. ANOVA test found statistically significant differences among groups (p<0.001). Tukey's test found that the smallest discrepancy occurred in group cn, followed by cc, while the st group presented the highest difference (cc x cn: p=0.007; st x cn: p<0.001; st x cc: p<0.001)
    corecore