3 research outputs found

    Imaging Quality Control, Methodology Harmonization and Clinical Data Management in Stress Echo 2030

    No full text
    Stress echo (SE) 2030 study is an international, prospective, multicenter cohort study that will include >10,000 patients from >= 20 centers from >= 10 countries. It represents the logical and chronological continuation of the SE 2020 study, which developed, validated, and disseminated the "ABCDE protocol" of SE, more suitable than conventional SE to describe the complex vulnerabilities of the contemporary patient within and beyond coronary artery disease. SE2030 was started with a recruitment plan from 2021 to 2025 (and follow-up to 2030) with 12 subprojects (ranging from coronary artery disease to valvular and post-COVID-19 patients). With these features, the study poses particular challenges on quality control assurance, methodological harmonization, and data management. One of the significant upgrades of SE2030 compared to SE2020 was developing and implementing a Research Electronic Data Capture (REDCap)-based infrastructure for interactive and entirely web-based data management to integrate and optimize reproducible clinical research data. The purposes of our paper were: first, to describe the methodology used for quality control of imaging data, and second, to present the informatic infrastructure developed on RedCap platform for data entry, storage, and management in a large-scale multicenter study

    Stress Echo 2030 : the novel ABCDE-(FGLPR) protocol to define the future of imaging

    No full text

    Stress echo 2030: The novel ABCDE-(FGLPR) protocol to define the future of imaging

    Get PDF
    With stress echo (SE) 2020 study, a new standard of practice in stress imaging was developed and disseminated: The ABCDE protocol for functional testing within and beyond CAD. ABCDE protocol was the fruit of SE 2020, and is the seed of SE 2030, which is articulated in 12 projects: 1-SE in coronary artery disease (SECAD); 2-SE in diastolic heart failure (SEDIA); 3-SE in hypertrophic cardiomyopathy (SEHCA); 4-SE post-chest radiotherapy and chemotherapy (SERA); 5-Artificial intelligence SE evaluation (AI-SEE); 6-Environmental stress echocardiography and air pollution (ESTER); 7-SE in repaired Tetralogy of Fallot (SETOF); 8-SE in post-COVID-19 (SECOV); 9: Recovery by stress echo of conventionally unfit donor good hearts (RESURGE); 10-SE for mitral ischemic regurgitation (SEMIR); 11-SE in valvular heart disease (SEVA); 12-SE for coronary vasospasm (SESPASM). The study aims to recruit in the next 5 years (2021-2025)≥10,000 patients followed for≥5 years (up to 2030) from≥20 quality-controlled laboratories from≥10 countries. In this COVID-19 era of sustainable health care delivery, SE2030 will provide the evidence to finally recommend SE as the optimal and versatile imaging modality for functional testing anywhere, any time, and in any patient
    corecore