11 research outputs found
Brain glucose concentrations in healthy humans subjected to recurrent hypoglycemia
Mechanisms responsible for hypoglycemia unawareness remain unknown. Previously, we found that patients with type 1 diabetes and hypoglycemia unawareness had increased brain glucose concentrations as measured by (1)H-magnetic resonance spectroscopy (MRS) compared with controls measured under the same metabolic condition, suggesting that an alteration in brain glucose transport and/or metabolism may play a role in the pathogenesis of hypoglycemia unawareness. To determine whether the brain glucose concentration is altered in normal subjects subjected to recurrent hypoglycemia, we compared the brain glucose concentrations measured in healthy subjects after three episodes of hypoglycemia to blunt the counterregulatory response over 24 hr and compared this value with that measured at a time remote from the antecedent hypoglycemia protocol. Sixteen subjects (9 M/7 F, age 36 +/- 10 years, mean +/- SD) underwent three hypoglycemic clamps for 30 min at 8 AM (0 hr), 5 PM (9 hr), and 7 AM (24 hr). After the third hypoglycemic clamp, subjects underwent a hyperglycemic clamp during which brain glucose concentration was measured by MRS at 4 T. Brain glucose concentration after repeated hypoglycemia was not different from the brain glucose concentration measured in the same subjects during a control study (5.1 +/- 0.8 vs. 4.5 +/- 0.5 mumol/g wet weight, respectively, P = 0.05). These observations suggest that brain glucose transport or metabolism is not altered following short episodes of recurrent hypoglycemia in healthy human volunteers
Consensus Recommendations for the Use of Automated Insulin Delivery (AID) Technologies in Clinical Practice
International audienceThe significant and growing global prevalence of diabetes continues to challenge people with diabetes (PwD), healthcare providers and payers. While maintaining near-normal glucose levels has been shown to prevent or delay the progression of the long-term complications of diabetes, a significant proportion of PwD are not attaining their glycemic goals. During the past six years, we have seen tremendous advances in automated insulin delivery (AID) technologies. Numerous randomized controlled trials and real-world studies have shown that the use of AID systems is safe and effective in helping PwD achieve their long-term glycemic goals while reducing hypoglycemia risk. Thus, AID systems have recently become an integral part of diabetes management. However, recommendations for using AID systems in clinical settings have been lacking. Such guided recommendations are critical for AID success and acceptance. All clinicians working with PwD need to become familiar with the available systems in order to eliminate disparities in diabetes quality of care. This report provides much-needed guidance for clinicians who are interested in utilizing AIDs and presents a comprehensive listing of the evidence payers should consider when determining eligibility criteria for AID insurance coverage
Human brain glycogen content and metabolism: implications on its role in brain energy metabolism
Human brain glycogen content and metabolism: implications on its role in brain energy metabolism
The adult brain relies on glucose for its energy needs and stores it in the form of glycogen, primarily in astrocytes. Animal and culture studies indicate that brain glycogen may support neuronal function when the glucose supply from the blood is inadequate and/or during neuronal activation. However, the concentration of glycogen and rates of its metabolism in the human brain are unknown. We used in vivo localized 13C-NMR spectroscopy to measure glycogen content and turnover in the human brain. Nine healthy volunteers received intravenous infusions of [1-(13)C]glucose for durations ranging from 6 to 50 h, and brain glycogen labeling and washout were measured in the occipital lobe for up to 84 h. The labeling kinetics suggest that turnover is the main mechanism of label incorporation into brain glycogen. Upon fitting a model of glycogen metabolism to the time courses of newly synthesized glycogen, human brain glycogen content was estimated at approximately 3.5 micromol/g, i.e., three- to fourfold higher than free glucose at euglycemia. Turnover of bulk brain glycogen occurred at a rate of 0.16 micromol.g-1.h-1, implying that complete turnover requires 3-5 days. Twenty minutes of visual stimulation (n=5) did not result in detectable glycogen utilization in the visual cortex, as judged from similar [13C]glycogen levels before and after stimulation. We conclude that the brain stores a substantial amount of glycogen relative to free glucose and metabolizes this store very slowly under normal physiology
Measurement of cerebral oxidative glucose consumption in patients with type 1 diabetes mellitus and hypoglycemia unawareness using 13C nuclear magnetic resonance spectroscopy
Recommended from our members
Closed-loop insulin delivery in suboptimally controlled type 1 diabetes: a multicentre, 12-week randomised trial.
BACKGROUND: The achievement of glycaemic control remains challenging for patients with type 1 diabetes. We assessed the effectiveness of day-and-night hybrid closed-loop insulin delivery compared with sensor-augmented pump therapy in people with suboptimally controlled type 1 diabetes aged 6 years and older. METHODS: In this open-label, multicentre, multinational, single-period, parallel randomised controlled trial, participants were recruited from diabetes outpatient clinics at four hospitals in the UK and two centres in the USA. We randomly assigned participants with type 1 diabetes aged 6 years and older treated with insulin pump and with suboptimal glycaemic control (glycated haemoglobin [HbA1c] 7·5-10·0%) to receive either hybrid closed-loop therapy or sensor-augmented pump therapy over 12 weeks of free living. Training on study insulin pump and continuous glucose monitoring took place over a 4-week run-in period. Eligible subjects were randomly assigned using central randomisation software. Allocation to the two study groups was unblinded, and randomisation was stratified within centre by low (<8·5%) or high (≥8·5%) HbA1c. The primary endpoint was the proportion of time that glucose concentration was within the target range of 3·9-10·0 mmol/L at 12 weeks post randomisation. Analyses of primary outcome and safety measures were done in all randomised patients. The trial is registered with ClinicalTrials.gov, number NCT02523131, and is closed to accrual. FINDINGS: From May 12, 2016, to Nov 17, 2017, 114 individuals were screened, and 86 eligible patients were randomly assigned to receive hybrid closed-loop therapy (n=46) or sensor-augmented pump therapy (n=40; control group). The proportion of time that glucose concentration was within the target range was significantly higher in the closed-loop group (65%, SD 8) compared with the control group (54%, SD 9; mean difference in change 10·8 percentage points, 95% CI 8·2 to 13·5; p<0·0001). In the closed-loop group, HbA1c was reduced from a screening value of 8·3% (SD 0·6) to 8·0% (SD 0·6) after the 4-week run-in, and to 7·4% (SD 0·6) after the 12-week intervention period. In the control group, the HbA1c values were 8·2% (SD 0·5) at screening, 7·8% (SD 0·6) after run-in, and 7·7% (SD 0·5) after intervention; reductions in HbA1c percentages were significantly greater in the closed-loop group compared with the control group (mean difference in change 0·36%, 95% CI 0·19 to 0·53; p<0·0001). The time spent with glucose concentrations below 3·9 mmol/L (mean difference in change -0·83 percentage points, -1·40 to -0·16; p=0·0013) and above 10·0 mmol/L (mean difference in change -10·3 percentage points, -13·2 to -7·5; p<0·0001) was shorter in the closed-loop group than the control group. The coefficient of variation of sensor-measured glucose was not different between interventions (mean difference in change -0·4%, 95% CI -1·4% to 0·7%; p=0·50). Similarly, total daily insulin dose was not different (mean difference in change 0·031 U/kg per day, 95% CI -0·005 to 0·067; p=0·09) and bodyweight did not differ (mean difference in change 0·68 kg, 95% CI -0·34 to 1·69; p=0·19). No severe hypoglycaemia occurred. One diabetic ketoacidosis occurred in the closed-loop group due to infusion set failure. Two participants in each study group had significant hyperglycaemia, and there were 13 other adverse events in the closed-loop group and three in the control group. INTERPRETATION: Hybrid closed-loop insulin delivery improves glucose control while reducing the risk of hypoglycaemia across a wide age range in patients with suboptimally controlled type 1 diabetes. FUNDING: JDRF, NIHR, and Wellcome Trust
Recommended from our members
Young Children Have Higher Variability of Insulin Requirements: Observations During Hybrid Closed-Loop Insulin Delivery.
OBJECTIVE: To quantify age-related variability of insulin needs during day and night closed-loop insulin delivery. RESEARCH DESIGN AND METHODS: We retrospectively analyzed data from hybrid closed-loop studies involving young children (1-6 years old, n = 20), children (7-12 years, n = 21), adolescents (13-17 years, n = 15), and adults (>18 years, n = 58) with type 1 diabetes. The coefficient of variation quantified variability of insulin needs during 3 weeks of unrestricted-living hybrid closed-loop use. RESULTS: Data from 2,365 nights and 2,367 days in 114 participants were analyzed. The coefficient of variation of insulin delivery was higher in young children compared with adults (mean difference at nighttime 10.7 percentage points [95% CI 2.9-18.4], P = 0.003; daytime 6.4 percentage points [95% CI 2.0-10.9], P = 0.002) and compared with adolescents (mean difference at nighttime 10.2 percentage points [95% CI 0.0-20.4], P = 0.049; daytime 7.0 percentage points [95% CI 1.1-12.8], P = 0.014). CONCLUSIONS: Diabetes management in young children is complicated by higher variability in insulin requirements, supporting fast-track clinical practice adoption of closed-loop in this vulnerable population