186 research outputs found

    Scattering phase function spectrum makes reflectance spectrum measured from Intralipid phantoms and tissue sensitive to the device detection geometry

    Get PDF
    Reflectance spectra measured in Intralipid (IL) close to the source are sensitive to wavelength-dependent changes in reduced scattering coefficient (ΞΌβ€²s) and scattering phase function (PF). Experiments and simulations were performed using device designs with either single or separate optical fibers for delivery and collection of light in varying concentrations of IL. Spectral reflectance is not consistently linear with varying IL concentration, with PF-dependent effects observed for single fiber devices with diameters smaller than ten transport lengths and for separate source-detector devices that collected light at less than half of a transport length from the source. Similar effects are thought to be seen in tissue, limiting the ability to quantitatively compare spectra from different devices without compensation

    Optical Detection of Preneoplastic Lesions of the Central Airways

    Get PDF
    Current routine diagnosis of premalignant lesions of the central airways is hampered due to a limited sensitivity (white light bronchoscopy) and resolution (computer tomography (CT), positron emission tomography (PET)) of currently used techniques. To improve the detection of these subtle mucosal abnormalities, novel optical imaging bronchoscopic techniques have been developed over the past decade. In this review we highlight the technological developments in the field of endoscopic imaging, and describe their advantages and disadvantages in clinical use

    Extraction of Intrinsic Fluorescence from Single Fiber Fluorescence Measurements on a Turbid Medium: Experimental Validation

    Get PDF
    Abstract The detailed mechanisms associated with the influence of scattering and absorption properties on the fluorescence intensity sampled by a single optical fiber have recently been elucidated based on Monte Carlo simulated data. Here we develop an experimental single fiber fluorescence (SFF) spectroscopy setup and validate the Monte Carlo data and semi-empirical model equation that describes the SFF signal as a function of scattering. We present a calibration procedure that corrects the SFF signal for all system-related, wavelength dependent transmission efficiencies to yield an absolute value of intrinsic fluorescence. The validity of the Monte Carlo data and semi-empirical model is demonstrated using a set of fluorescent phantoms with varying concentrations of Intralipid to vary the scattering properties, yielding a wide range of reduced scattering coefficients (ΞΌβ€²s = 0–7 mm βˆ’1). We also introduce a small modification to the model to account for the case of ΞΌβ€²s = 0 mm βˆ’1 and show its relation to the experimental, simulated and theoretically calculated value of SFF intensity in the absence of scattering. Finally, we show that our method is also accurate in the presence of absorbers by performing measurements on phantoms containing red blood cells and correcting for their absorption properties

    In vivo quantification of photosensitizer fluorescence in the skin-fold observation chamber using dual-wavelength excitation and NIR imaging

    Get PDF
    A major challenge in biomedical optics is the accurate quantification of in vivo fluorescence images. Fluorescence imaging is often used to determine the pharmacokinetics of photosensitizers used for photodynamic therapy. Often, however, this type of imaging does not take into account differences in and changes to tissue volume and optical properties of the tissue under interrogation. To address this problem, a ratiometric quantification method was developed and applied to monitor photosensitizer meso-tetra (hydroxyphenyl) chlorin (mTHPC) pharmacokinetics in the rat skin-fold observation chamber. The method employs a combination of dual-wavelength excitation and dualwavelength detection. Excitation and detection wavelengths were selected in the NIR region. One excitation wavelength was chosen to be at the Q band of mTHPC, whereas the second excitation wavelength was close to its absorption minimum. Two fluorescence emission bands were used; one at the secondary fluorescence maximum of mTHPC centered on 720 nm, and one in a region of tissue autofluorescence. The first excitation wavelength was used to excite the mTHPC and autofluorescence and the second to excite only autofluorescence, so that this could be subtracted. Subsequently, the autofluorescence-corrected mTHPC image was divided by the autofluorescence signal to correct for variations in tissue optical properties. This correction algorithm in principle results in a linear relation between the corrected fluorescence and photosensitizer concentration. The limitations of the presented method and comparison with previously published and validated techniques are discussed

    In vivo quantification of photosensitizer concentration using fluorescence differential path-length spectroscopy:influence of photosensitizer formulation and tissue location

    Get PDF
    In vivo measurement of photosensitizer concentrations may optimize clinical photodynamic therapy (PDT). Fluorescence differential path-length spectroscopy (FDPS) is a non-invasive optical technique that has been shown to accurately quantify the concentration of Foscan (R) in rat liver. As a next step towards clinical translation, the effect of two liposomal formulations of mTHPC, Fospeg (R) and Foslip (R), on FDPS response was investigated. Furthermore, FDPS was evaluated in target organs for head-and-neck PDT. Fifty-four healthy rats were intravenously injected with one of the three formulations of mTHPC at 0.15 mgkg(-1). FDPS was performed on liver, tongue, and lip. The mTHPC concentrations estimated using FDPS were correlated with the results of the subsequent harvested and chemically extracted organs. An excellent goodness of fit (R-2) between FDPS and extraction was found for all formulations in the liver (R-2 = 0.79). A much lower R-2 between FDPS and extraction was found in lip (R-2 = 0.46) and tongue (R-2 = 0.10). The lower performance in lip and in particular tongue was mainly attributed to the more layered anatomical structure, which influences scattering properties and photosensitizer distribution. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO. 17.6.067001

    The future of medical diagnostics: Review paper

    Get PDF
    While histopathology of excised tissue remains the gold standard for diagnosis, several new, non-invasive diagnostic techniques are being developed. They rely on physical and biochemical changes that precede and mirror malignant change within tissue. The basic principle involves simple optical techniques of tissue interrogation. Their accuracy, expressed as sensitivity and specificity, are reported in a number of studies suggests that they have a potential for cost effective, real-time, in situ diagnosis. We review the Third Scientific Meeting of the Head and Neck Optical Diagnostics Society held in Congress Innsbruck, Innsbruck, Austria on the 11th May 2011. For the first time the HNODS Annual Scientific Meeting was held in association with the International Photodynamic Association (IPA) and the European Platform for Photodynamic Medicine (EPPM). The aim was to enhance the interdisciplinary aspects of optical diagnostics and other photodynamic applications. The meeting included 2 sections: oral communication sessions running in parallel to the IPA programme and poster presentation sessions combined with the IPA and EPPM posters sessions. Β© 2011 Jerjes et al; licensee BioMed Central Ltd

    Apoptosis- and necrosis-induced changes in light attenuation measured by optical coherence tomography

    Get PDF
    Optical coherence tomography (OCT) was used to determine optical properties of pelleted human fibroblasts in which necrosis or apoptosis had been induced. We analysed the OCT data, including both the scattering properties of the medium and the axial point spread function of the OCT system. The optical attenuation coefficient in necrotic cells decreased from 2.2 ± 0.3Β mmβˆ’1 to 1.3 ± 0.6Β mmβˆ’1, whereas, in the apoptotic cells, an increase to 6.4 ± 1.7Β mmβˆ’1 was observed. The results from cultured cells, as presented in this study, indicate the ability of OCT to detect and differentiate between viable, apoptotic, and necrotic cells, based on their attenuation coefficient. This functional supplement to high-resolution OCT imaging can be of great clinical benefit, enabling on-line monitoring of tissues, e.g. for feedback in cancer treatment

    Regional perinatal mortality differences in the Netherlands; care is the question

    Get PDF
    Background. Perinatal mortality is an important indicator of health. European comparisons of perinatal mortality show an unfavourable position for the Netherlands. Our objective was to study regional variation in perinatal mortality within the Netherlands and to identify possible explanatory factors for the found differences. Methods. Our study population comprised of all singleton births (904,003) derived from the Netherlands Perinatal Registry for the period 2000-2004. Perinatal mortality including stillbirth from 22+0weeks gestation and early neonatal death (0-6 days) was our main outcome measure. Differences in perinatal mortality were calculated between 4 distinct geographical regions North-East-South-West. We tried to explain regional differences by adjustment for the demographic factors maternal age, parity and ethnicity and by socio-economic status and urbanisation degree using logistic modelling. In addition, regional differences in mode of delivery and risk selection were analysed as health care factors. Finally, perinatal mortality was analysed among five distinct clinical risk groups based on the mediating risk factors gestational age and congenital anomalies. Results. Overall perinatal mortality was 10.1 per 1,000 total births over the period 2000-2004. Perinatal mortality was elevated in the northern region (11.2 per 1,000 total births). Perinatal mortality in the eastern, western and southern region was 10.2, 10.1 and 9.6 per 1,000 total births respectively. Adjustment for demographic factors increased the perinatal mortality risk in the northern region (odds ratio 1.20, 95% CI 1.12-1.28, compared to reference western region), subsequent adjustment for socio-economic status and urbanisation explained a small part of the elevated risk (odds ratio 1.11, 95% CI 1.03-1.20). Risk group analysis showed that regional differences were absent among very preterm births (22+0- 25+6weeks gestation) and most prominent among births from 32+0gestation weeks onwards and among children with severe congenital anomalies. Among term births (37+0weeks) regional mortality differences were largest for births in women transferred from low to high risk during delivery. Conclusion. Regional differences in perinatal mortality exist in the Netherlands. These differences could not be explained by demographic or socio-economic factors, however clinical risk group analysis showed indications for a role of health care factors
    • …
    corecore