122 research outputs found
Stress compensation by gap monolayers for stacked InAs/GaAs quantum dots solar cells
In this work we report the stacking of 10 and 50 InAs quantum dots layers using 2 monolayers of GaP for stress compensation and a stack period of 18 nm on GaAs (001) substrates. Very good structural and optical quality is found in both samples. Vertical alignment of the dots is observed by transmission electron microscopy suggesting the existence of residual stress around them. Photocurrent measurements show light absorption up to 1.2 ÎŒm in the nanostructures together with a reduction in the blue response of the device. As a result of the phosphorus incorporation in the barriers, a very high thermal activation energy (431 meV) has also been obtained for the quantum dot emission
Magnetic fields inferred by Solar Orbiter: A comparison between SO/PHI-HRT and SDO/HMI
The High Resolution Telescope (HRT) of the Polarimetric and Helioseismic
Imager on board the Solar Orbiter spacecraft (SO/PHI) and the Helioseismic and
Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO) both infer
the photospheric magnetic field from polarised light images. SO/PHI is the
first magnetograph to move out of the Sun--Earth line and will provide
unprecedented access to the Sun's poles. This provides excellent opportunities
for new research wherein the magnetic field maps from both instruments are used
simultaneously. We aim to compare the magnetic field maps from these two
instruments and discuss any possible differences between them. We used data
from both instruments obtained during Solar Orbiter's inferior conjunction on 7
March 2022. The HRT data were additionally treated for geometric distortion and
degraded to the same resolution as HMI. The HMI data were re-projected to
correct for the separation between the two observatories.
SO/PHI-HRT and HMI produce remarkably similar line-of-sight magnetograms, with
a slope coefficient of , an offset below G, and a Pearson correlation
coefficient of . However, SO/PHI-HRT infers weaker line-of-sight fields
for the strongest fields. As for the vector magnetic field, SO/PHI-HRT was
compared to both the -second and -second HMI vector magnetic field:
SO/PHI-HRT has a closer alignment with the -second HMI vector. In the weak
signal regime ( G), SO/PHI-HRT measures stronger and more horizontal
fields than HMI, very likely due to the greater noise in the SO/PHI-HRT data.
In the strong field regime ( G), HRT infers lower field strengths
but with similar inclinations (a slope of ) and azimuths (a slope of
). The slope values are from the comparison with the HMI -second
vector.Comment: 10 pages, 5 figures, accepted for publication in A&A; manuscript is a
part of Astronomy & Astrophysics special issue: Solar Orbiter First Results
(Nominal Mission Phase
Prognostic Value of D-dimer to Lymphocyte Ratio (DLR) in Hospitalized Coronavirus Disease 2019 (COVID-19) Patients: A Validation Study in a National Cohort
Background: This study aimed to validate the role of the D-dimer to lymphocyte ratio (DLR) for mortality prediction in a large national cohort of hospitalized coronavirus disease 2019 (COVID-19) patients. Methods: A retrospective, multicenter, observational study that included hospitalized patients due to SARS-CoV-2 infection in Spain was conducted from March 2020 to March 2022. All biomarkers and laboratory indices analyzed were measured once at admission. Results: A total of 10,575 COVID-19 patients were included in this study. The mean age of participants was 66.9 (+/- 16) years, and 58.6% (6202 patients) of them were male. The overall mortality rate was 16.3% (n = 1726 patients). Intensive care unit admission was needed in 10.5% (n = 1106 patients), non-invasive mechanical ventilation was required in 8.8% (n = 923 patients), and orotracheal intubation was required in 7.5% (789 patients). DLR presented a c-statistic of 0.69 (95% CI, 0.68-0.71) for in-hospital mortality with an optimal cut-off above 1. Multivariate analysis showed an independent association for in-hospital mortality for DLR > 1 (adjusted OR 2.09, 95% CI 1.09-4.04; p = 0.03); in the same way, survival analysis showed a higher mortality risk for DLR > 1 (HR 2.24; 95% CI 2.03-2.47; p < 0.01). Further, no other laboratory indices showed an independent association for mortality in multivariate analysis. Conclusions: This study confirmed the usefulness of DLR as a prognostic biomarker for mortality associated with SARS-CoV-2 infection, being an accessible, cost-effective, and easy-to-use biomarker in daily clinical practice
Wavefront error of PHI/HRT on Solar Orbiter at various heliocentric distances
We use wavefront sensing to characterise the image quality of the the High
Resolution Telescope (HRT) of the Polarimetric and Helioseismic Imager (SO/PHI)
data products during the second remote sensing window of the Solar Orbiter (SO)
nominal mission phase. Our ultimate aims are to reconstruct the HRT data by
deconvolving with the HRT point spread function (PSF) and to correct for the
effects of optical aberrations on the data. We use a pair of focused--defocused
images to compute the wavefront error and derive the PSF of HRT by means of a
phase diversity (PD) analysis. The wavefront error of HRT depends on the
orbital distance of SO to the Sun. At distances \,au, the wavefront error
is small, and stems dominantly from the inherent optical properties of HRT. At
distances \,au, the thermo-optical effect of the Heat Rejection Entrance
Window (HREW) becomes noticeable. We develop an interpolation scheme for the
wavefront error that depends on the thermal variation of the HREW with the
distance of SO to the Sun. We also introduce a new level of image
reconstruction, termed `aberration correction', which is designed to reduce the
noise caused by image deconvolution while removing the aberrations caused by
the HREW. The computed PSF via phase diversity significantly reduces the
degradation caused by the HREW in the near-perihelion HRT data. In addition,
the aberration correction increases the noise by a factor of only
compared to the factor of increase that results from the usual PD
reconstructions
The ratio of horizontal to vertical displacement in solar oscillations estimated from combined SO/PHI and SDO/HMI observations
In order to make accurate inferences about the solar interior using
helioseismology, it is essential to understand all the relevant physical
effects on the observations. One effect to understand is the (complex-valued)
ratio of the horizontal to vertical displacement of the p- and f-modes at the
height at which they are observed. Unfortunately, it is impossible to measure
this ratio directly from a single vantage point, and it has been difficult to
disentangle observationally from other effects. In this paper we attempt to
measure the ratio directly using 7.5 hours of simultaneous observations from
the Polarimetric and Helioseismic Imager on board Solar Orbiter and the
Helioseismic and Magnetic Imager on board the Solar Dynamics Observatory. While
image geometry problems make it difficult to determine the exact ratio, it
appears to agree well with that expected from adiabatic oscillations in a
standard solar model. On the other hand it does not agree with a commonly used
approximation, indicating that this approximation should not be used in
helioseismic analyses. In addition, the ratio appears to be real-valued.Comment: Accepted for publication in Astronomy & Astrophysics. 8 pages, 8
figure
Intensity contrast of solar network and faculae close to the solar limb, observed from two vantage points
The brightness of faculae and network depends on the angle at which they are
observed and the magnetic flux density. Close to the limb, assessment of this
relationship has until now been hindered by the increasingly lower signal in
magnetograms. This preliminary study aims at highlighting the potential of
using simultaneous observations from different vantage points to better
determine the properties of faculae close to the limb. We use data from the
Solar Orbiter/Polarimetric and Helioseismic Imager (SO/PHI), and the Solar
Dynamics Observatory/Helioseismic and Magnetic Imager (SDO/HMI), recorded at
angular separation of their lines of sight at the Sun. We use
continuum intensity observed close to the limb by SO/PHI and complement it with
the co-observed from SDO/HMI, originating closer to disc centre
(as seen by SDO/HMI), thus avoiding the degradation of the magnetic field
signal near the limb. We derived the dependence of facular brightness in the
continuum on disc position and magnetic flux density from the combined
observations of SO/PHI and SDO/HMI. Compared with a single point of view, we
were able to obtain contrast values reaching closer to the limb and to lower
field strengths. We find the general dependence of the limb distance at which
the contrast is maximum on the flux density to be at large in line with single
viewpoint observations, in that the higher the flux density is, the closer the
turning point lies to the limb. There is a tendency, however, for the maximum
to be reached closer to the limb when determined from two vantage points. We
note that due to the preliminary nature of this study, these results must be
taken with caution. Our analysis shows that studies involving two viewpoints
can significantly improve the detection of faculae near the solar limb and the
determination of their brightness contrast relative to the quiet Sun
Coronal voids and their magnetic nature
Context:
Extreme ultraviolet (EUV) observations of the quiet solar atmosphere reveal extended regions of weak emission compared to the ambient quiescent corona. The magnetic nature of these coronal features is not well understood.
//
Aims:
We study the magnetic properties of the weakly emitting extended regions, which we name coronal voids. In particular, we aim to understand whether these voids result from a reduced heat input into the corona or if they are associated with mainly unipolar and possibly open magnetic fields, similar to coronal holes.
//
Methods:
We defined the coronal voids via an intensity threshold of 75% of the mean quiet-Sun (QS) EUV intensity observed by the high-resolution EUV channel (HRIEUV) of the Extreme Ultraviolet Imager on Solar Orbiter. The line-of-sight magnetograms of the same solar region recorded by the High Resolution Telescope of the Polarimetric and Helioseismic Imager allowed us to compare the photospheric magnetic field beneath the coronal voids with that in other parts of the QS.
//
Results:
The coronal voids studied here range in size from a few granules to a few supergranules and on average exhibit a reduced intensity of 67% of the mean value of the entire field of view. The magnetic flux density in the photosphere below the voids is 76% (or more) lower than in the surrounding QS. Specifically, the coronal voids show much weaker or no network structures. The detected flux imbalances fall in the range of imbalances found in QS areas of the same size.
//
Conclusions:
We conclude that coronal voids form because of locally reduced heating of the corona due to reduced magnetic flux density in the photosphere. This makes them a distinct class of (dark) structure, different from coronal holes
Coronal voids and their magnetic nature
Context. Extreme ultraviolet (EUV) observations of the quiet solar atmosphere reveal extended regions of weak emission compared to the ambient quiescent corona. The magnetic nature of these coronal features is not well understood.Aims. We study the magnetic properties of the weakly emitting extended regions, which we name coronal voids. In particular, we aim to understand whether these voids result from a reduced heat input into the corona or if they are associated with mainly unipolar and possibly open magnetic fields, similar to coronal holes. Methods. We defined the coronal voids via an intensity threshold of 75% of the mean quiet-Sun (QS) EUV intensity observed by the high- resolution EUV channel (HRIEUV) of the Extreme Ultraviolet Imager on Solar Orbiter. The line-of-sight magnetograms of the same solar region recorded by the High Resolution Telescope of the Polarimetric and Helioseismic Imager allowed us to compare the photospheric magnetic field beneath the coronal voids with that in other parts of the QS.Results. The coronal voids studied here range in size from a few granules to a few supergranules and on average exhibit a reduced intensity of 67% of the mean value of the entire field of view. The magnetic flux density in the photosphere below the voids is 76% (or more) lower than in the surrounding QS. Specifically, the coronal voids show much weaker or no network structures. The detected flux imbalances fall in the range of imbalances found in QS areas of the same size. Conclusions. We conclude that coronal voids form because of locally reduced heating of the corona due to reduced magnetic flux density in the photosphere. This makes them a distinct class of (dark) structure, different from coronal holes
Natural History of MYH7-Related Dilated Cardiomyopathy
BACKGROUND Variants in myosin heavy chain 7 (MYH7) are responsible for disease in 1% to 5% of patients with dilated cardiomyopathy (DCM); however, the clinical characteristics and natural history of MYH7-related DCM are poorly described. OBJECTIVES We sought to determine the phenotype and prognosis of MYH7-related DCM. We also evaluated the influence of variant location on phenotypic expression. METHODS We studied clinical data from 147 individuals with DCM-causing MYH7 variants (47.6% female; 35.6 +/- 19.2 years) recruited from 29 international centers. RESULTS At initial evaluation, 106 (72.1%) patients had DCM (left ventricular ejection fraction: 34.5% +/- 11.7%). Median follow-up was 4.5 years (IQR: 1.7-8.0 years), and 23.7% of carriers who were initially phenotype-negative developed DCM. Phenotypic expression by 40 and 60 years was 46% and 88%, respectively, with 18 patients (16%) first diagnosed at <18 years of age. Thirty-six percent of patients with DCM met imaging criteria for LV noncompaction. During follow-up, 28% showed left ventricular reverse remodeling. Incidence of adverse cardiac events among patients with DCM at 5 years was 11.6%, with 5 (4.6%) deaths caused by end-stage heart failure (ESHF) and 5 patients (4.6%) requiring heart transplantation. The major ventricular arrhythmia rate was low (1.0% and 2.1% at 5 years in patients with DCM and in those with LVEF of <= 35%, respectively). ESHF and major ventricular arrhythmia were significantly lower compared with LMNA-related DCM and similar to DCM caused by TTN truncating variants. CONCLUSIONS MYH7-related DCM is characterized by early age of onset, high phenotypic expression, low left ventricular reverse remodeling, and frequent progression to ESHF. Heart failure complications predominate over ventricular arrhythmias, which are rare. (C) 2022 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation
Spectropolarimetric investigation of magnetohydrodynamic wave modes in the photosphere: First results from PHI on board Solar Orbiter
This is an Open Access article, published by EDP Sciences, under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.Context. In November 2021, Solar Orbiter started its nominal mission phase. The remote-sensing instruments on board the spacecraft acquired scientific data during three observing windows surrounding the perihelion of the first orbit of this phase. Aims. The aim of the analysis is the detection of magnetohydrodynamic (MHD) wave modes in an active region by exploiting the capabilities of spectropolarimetric measurements. Mthods. The High Resolution Telescope (HRT) of the Polarimetric and Helioseismic Imager (SO/PHI) on board the Solar Orbiter acquired a high-cadence data set of an active region. This is studied in the paper. B-Ï and phase-difference analyses are applied on line-of-sight velocity and circular polarization maps and other averaged quantities. Results. We find that several MHD modes at different frequencies are excited in all analysed structures. The leading sunspot shows a linear dependence of the phase lag on the angle between the magnetic field and the line of sight of the observer in its penumbra. The magnetic pore exhibits global resonances at several frequencies, which are also excited by different wave modes. Conclusions. The SO/PHI measurements clearly confirm the presence of magnetic and velocity oscillations that are compatible with one or more MHD wave modes in pores and a sunspot. Improvements in modelling are still necessary to interpret the relation between the fluctuations of different diagnostics. © The Authors 2023.Solar Orbiter is a space mission of international collaboration between ESA and NASA, operated by ESA. We are grateful to the ESA SOC and MOC teams for their support. The German contribution to SO/PHI is funded by the BMWi through DLR and by MPG central funds. The Spanish contribution is funded by AEI/MCIN/10.13039/501100011033/ (RTI2018-096886-C5, PID2021-125325OB-C5, PCI2022-135009-2) and ERDF âA way of making Europeâ; âCenter of Excellence Severo Ochoaâ awards to IAA-CSIC (SEV-2017-0709, CEX2021-001131-S); and a RamĂłn y Cajal fellowship awarded to DOS. The French contribution is funded by CNES. The authors wish to acknowledge scientific discussions with the Waves in the Lower Solar Atmosphere (WaLSA; https://WaLSA.team) team, which has been supported by the Research Council of Norway (project no. 262622), The Royal Society (award no. Hooke18b/SCTM), and the International Space Science Institute (ISSI Team 502).Peer reviewe
- âŠ