3 research outputs found

    IV Brazilian Guidelines for autoantibodies on HEp-2 cells

    Get PDF
    Objective: the Fourth Brazilian Consensus for Autoantibodies Screening in HEp-2 Cells (ANA) was held in Vitoria, Espirito Santo, and aimed to discuss strategies and recommendations about the technique, standardization, interpretation and quality control of the indirect immunofluorescence reaction on HEp-2 cells.Methods: Twenty three ANA experts from university centers and private laboratories in different areas from Brazil discussed and agreed upon recommendations for the fourth edition of the Brazilian Consensus for Autoantibodies Screening in HEp-2 Cells.Results and conclusion: the 4th ANA Consensus included three novel patterns into the existing algorithm (cytoplasmic Rods and Rings, nuclear Quasi-homogeneous, and CENP-F). Emphasis was given to the need of attention in describing the peculiar mixed pattern elicited by anti-DNA topoisomerase I (Scl-70) autoantibodies, comprising nuclear fine specked, nucleolar homogeneous pattern, NOR staining in metaphase plates, and cytoplasmic fine speckled patterns. the group also emphasized the need for continuous quality control in indirect immunofluorescence assays, the establishment of screening dilutions, as well as conjugate titration. An alert was made regarding the heterogeneity of commercial kits in defining patterns and the use of solid phase methodologies to determine the presence of autoantibodies. (C) 2014 Elsevier Editora Ltda. All rights reserved.Objetivo: O IV Consenso Brasileiro para Pesquisa de Autoanticorpos em Células HEp-2 (FAN) realizado em Vitória (ES), no dia 18 de setembro de 2012, objetivou discutir estratégias e recomendações relacionadas ao procedimento técnico, à padronização e à interpretação dos resultados da pesquisa de autoanticorpos em células HEp-2. Métodos: Participaram do evento 23 pesquisadores e especialistas de Universidades e laboratórios brasileiros. Foram abordados diferentes tópicos, discutidos amplamente a fim de se estabelecer recomendações específicas. Resultados e conclusão: O IV Consenso integrou à árvore de decisão o padrão citoplasmático em Anéis e Bastões, o padrão nuclear pontilhado Quasi-homogêneo (QH) e o padrão misto CENP-F. Discutiu-se ainda a necessidade de atenção para a classificação do padrão misto relacionado à presença de anticorpos anti-DNA topoisomerase I (Scl-70), compreendendo os componentes nuclear pontilhado fino, nucleolar homogêneo, NOR na placa metafásica e citoplasmático pontilhado fino. Foram sugeridas diretrizes para o controle de qualidade do teste, diluição de triagem e diluição de esgotamento, e foi emitido alerta quanto à necessidade de atenção em relação à heterogeneidade de substratos disponíveis no mercado e a utilização de metodologias automatizadas para detecção de autoanticorpos.Albert Einstein Medicina DiagnosticaAlka TecnologiaAmaral Costa LaboratorioConselho Federal de BiomedicinaDASAEuroimmun BrasilGrupo FleuryHemagenMedivaxOlimpusPadrao Laboratorio ClinicPontificia Universidade Catolica de Goias - PUC-GoiasSociedade Brasileira de Patologia Clinica e Medicina LaboratorialSociedade Brasileira de ReumatologiaThermo ScientificWama DiagnosticaWerfen Group - Werfen MedicalHermes PardiniConselho Regional de Biomedicina - 3a RegiaoPUC Goias, Goiania, Go, BrazilFleury Med & Saude, São Paulo, BrazilUniversidade Federal de São Paulo UNIFESP, Discipline Rheumatol, São Paulo, BrazilUniv Fed Uberlandia, Hosp Clin, Serv Rheumatol, BR-38400 Uberlandia, MG, BrazilClin Doencas Reumat Porto Alegre, Ctr Diagnost Med & Rheuma, Porto Alegre, RS, BrazilAmaral Costa Med Diagnost, Belem, PA, BrazilUniv São Paulo, Fac Med, Hosp Clin, Lab Invest Med, São Paulo, BrazilUniv São Paulo, Fac Med, Hosp Clin, Lab Cent, São Paulo, BrazilHosp Israelita Albert Einstein, Dept Clin Pathol, São Paulo, BrazilInst Hermes Pardini, Belo Horizonte, MG, BrazilUniv São Paulo, Fac Med, São Paulo, BrazilUniv Fed Minas Gerais, Fac Med, Belo Horizonte, MG, BrazilUniv Catolica Brasilia, Brasilia, DF, BrazilUniv Fed Goias, Fac Med, Goiania, Go, BrazilUniv Sul Santa Catarina UNISUL, Florianopolis, SC, BrazilUniv Vale do Itajai UNIVALE, Florianopolis, SC, BrazilUniv Fed Espirito Santo, Vitoria, ES, BrazilEBMSP, Salvador, BA, BrazilGrp DASA, São Paulo, BrazilEscola Super Ciencias Saude Dist Fed, Brasilia, DF, BrazilLab Sabin, Brasilia, DF, BrazilUniversidade Federal de São Paulo UNIFESP, Discipline Rheumatol, São Paulo, BrazilWeb of Scienc

    IV Consenso Brasileiro para pesquisa de autoanticorpos em células HEp-2

    Get PDF
    Objetivo: O IV Consenso Brasileiro para Pesquisa de Autoanticorpos em Células HEp-2 (FAN) realizado em Vitória (ES), no dia 18 de setembro de 2012, objetivou discutir estratégias e recomendações relacionadas ao procedimento técnico, à padronização e à interpretação dos resultados da pesquisa de autoanticorpos em células HEp-2. Métodos: Participaram do evento 23 pesquisadores e especialistas de Universidades e laboratórios brasileiros. Foram abordados diferentes tópicos, discutidos amplamente a fim de se estabelecer recomendações específicas. Resultados e conclusão: O IV Consenso integrou à árvore de decisão o padrão citoplasmático em Anéis e Bastões, o padrão nuclear pontilhado Quasi-homogêneo (QH) e o padrão misto CENP-F. Discutiu-se ainda a necessidade de atenção para a classificação do padrão misto relacionado à presença de anticorpos anti-DNA topoisomerase I (Scl70), compreendendo os componentes nuclear pontilhado fino, nucleolar homogêneo, NOR na placa metafásica e citoplasmático pontilhado fino. Foram sugeridas diretrizes para o controle de qualidade do teste, diluição de triagem e diluição de esgotamento, e foi emitido alerta quanto à necessidade de atenção em relação à heterogeneidade de substratos disponíveis no mercado e a utilização de metodologias automatizadas para detecção de autoanticorpos
    corecore