67 research outputs found

    Validity and Reliability of Dermoscopic Criteria Used to Differentiate Nevi From Melanoma: A Web-Based International Dermoscopy Society Study.

    Get PDF
    IMPORTANCE: The comparative diagnostic performance of dermoscopic algorithms and their individual criteria are not well studied. OBJECTIVES: To analyze the discriminatory power and reliability of dermoscopic criteria used in melanoma detection and compare the diagnostic accuracy of existing algorithms. DESIGN, SETTING, AND PARTICIPANTS: This was a retrospective, observational study of 477 lesions (119 melanomas [24.9%] and 358 nevi [75.1%]), which were divided into 12 image sets that consisted of 39 or 40 images per set. A link on the International Dermoscopy Society website from January 1, 2011, through December 31, 2011, directed participants to the study website. Data analysis was performed from June 1, 2013, through May 31, 2015. Participants included physicians, residents, and medical students, and there were no specialty-type or experience-level restrictions. Participants were randomly assigned to evaluate 1 of the 12 image sets. MAIN OUTCOMES AND MEASURES: Associations with melanoma and intraclass correlation coefficients (ICCs) were evaluated for the presence of dermoscopic criteria. Diagnostic accuracy measures were estimated for the following algorithms: the ABCD rule, the Menzies method, the 7-point checklist, the 3-point checklist, chaos and clues, and CASH (color, architecture, symmetry, and homogeneity). RESULTS: A total of 240 participants registered, and 103 (42.9%) evaluated all images. The 110 participants (45.8%) who evaluated fewer than 20 lesions were excluded, resulting in data from 130 participants (54.2%), 121 (93.1%) of whom were regular dermoscopy users. Criteria associated with melanoma included marked architectural disorder (odds ratio [OR], 6.6; 95% CI, 5.6-7.8), pattern asymmetry (OR, 4.9; 95% CI, 4.1-5.8), nonorganized pattern (OR, 3.3; 95% CI, 2.9-3.7), border score of 6 (OR, 3.3; 95% CI, 2.5-4.3), and contour asymmetry (OR, 3.2; 95% CI, 2.7-3.7) (P < .001 for all). Most dermoscopic criteria had poor to fair interobserver agreement. Criteria that reached moderate levels of agreement included comma vessels (ICC, 0.44; 95% CI, 0.40-0.49), absence of vessels (ICC, 0.46; 95% CI, 0.42-0.51), dark brown color (ICC, 0.40; 95% CI, 0.35-0.44), and architectural disorder (ICC, 0.43; 95% CI, 0.39-0.48). The Menzies method had the highest sensitivity for melanoma diagnosis (95.1%) but the lowest specificity (24.8%) compared with any other method (P < .001). The ABCD rule had the highest specificity (59.4%). All methods had similar areas under the receiver operating characteristic curves. CONCLUSIONS AND RELEVANCE: Important dermoscopic criteria for melanoma recognition were revalidated by participants with varied experience. Six algorithms tested had similar but modest levels of diagnostic accuracy, and the interobserver agreement of most individual criteria was poor

    Validity and reliability of dermoscopic criteria used to differentiate nevi from melanoma aweb-based international dermoscopy society study

    Get PDF
    IMPORTANCE The comparative diagnostic performance of dermoscopic algorithms and their individual criteria are not well studied. OBJECTIVES To analyze the discriminatory power and reliability of dermoscopic criteria used in melanoma detection and compare the diagnostic accuracy of existing algorithms. DESIGN, SETTING, AND PARTICIPANTS Thiswas a retrospective, observational study of 477 lesions (119 melanomas [24.9%] and 358 nevi [75.1%]), which were divided into 12 image sets that consisted of 39 or 40 images per set. A link on the International Dermoscopy Society website from January 1, 2011, through December 31, 2011, directed participants to the study website. Data analysis was performed from June 1, 2013, through May 31, 2015. Participants included physicians, residents, and medical students, and there were no specialty-Type or experience-level restrictions. Participants were randomly assigned to evaluate 1 of the 12 image sets. MAIN OUTCOMES AND MEASURES Associations with melanoma and intraclass correlation coefficients (ICCs) were evaluated for the presence of dermoscopic criteria. Diagnostic accuracy measures were estimated for the following algorithms: The ABCD rule, the Menzies method, the 7-point checklist, the 3-point checklist, chaos and clues, and CASH (color, architecture, symmetry, and homogeneity). RESULTS A total of 240 participants registered, and 103 (42.9%) evaluated all images. The 110 participants (45.8%) who evaluated fewer than 20 lesions were excluded, resulting in data from 130 participants (54.2%), 121 (93.1%) of whom were regular dermoscopy users. Criteria associated with melanoma included marked architectural disorder (odds ratio [OR], 6.6; 95%CI, 5.6-7.8), pattern asymmetry (OR, 4.9; 95%CI, 4.1-5.8), nonorganized pattern (OR, 3.3; 95%CI, 2.9-3.7), border score of 6 (OR, 3.3; 95%CI, 2.5-4.3), and contour asymmetry (OR, 3.2; 95%CI, 2.7-3.7) (P &lt; .001 for all). Most dermoscopic criteria had poor to fair interobserver agreement. Criteria that reached moderate levels of agreement included comma vessels (ICC, 0.44; 95%CI, 0.40-0.49), absence of vessels (ICC, 0.46; 95%CI, 0.42-0.51), dark brown color (ICC, 0.40; 95%CI, 0.35-0.44), and architectural disorder (ICC, 0.43; 95%CI, 0.39-0.48). The Menziesmethod had the highest sensitivity for melanoma diagnosis (95.1%) but the lowest specificity (24.8%) compared with any other method (P &lt; .001). The ABCD rule had the highest specificity (59.4%). All methods had similar areas under the receiver operating characteristic curves. CONCLUSIONS AND RELEVANCE Important dermoscopic criteria for melanoma recognition were revalidated by participants with varied experience. Six algorithms tested had similar but modest levels of diagnostic accuracy, and the interobserver agreement of most individual criteria was poor

    Reflectance confocal microscopy and features of melanocytic lesions: An internet-based study of the reproducibility of terminology

    Get PDF
    Objective: To test the interobserver and intraobserver reproducibility of the standard terminology for description and diagnosis of melanocytic lesions in in vivo confocal microscopy. Design: A dedicated Web platform was developed to train the participants and to allow independent distant evaluations of confocal images via the Internet. Setting: Department of Dermatology, University of Modena and Reggio Emilia, Modena, Italy. Participants: The study population was composed of 15 melanomas, 30 nevi, and 5 Spitz/Reed nevi. Six expert centers were invited to participate at the study. Intervention: Evaluation of 36 features in 345 confocal microscopic images from melanocytic lesions. Main Outcome Measure: Interobserved and intraobserved agreement, by calculating the Cohen κ statistics measure for each descriptor. Results: High overall levels of reproducibility were shown for most of the evaluated features. In both the training and test sets there was a parallel trend of decreasing κ values as deeper anatomic skin levels were evaluated. All of the features, except 1, used for melanoma diagnosis, including roundish pagetoid cells, nonedged papillae, atypical cells in basal layer, cerebriform clusters, and nucleated cells infiltrating dermal papillae, showed high overall levels of reproducibility. However, less-than-ideal reproducibility was obtained for some descriptors, such as grainy appearance of the epidermis, junctional thickening, mild atypia in basal layer, plump bright cells, small bright cells, and reticulated fibers in the dermis. Conclusion: The standard consensus confocal terminology useful for the evaluation of melanocytic lesions was reproducibly recognized by independent observers. ©2009 American Medical Association. All rights reserved.This study was supported in part by a grant from the Istituto Superiore di Sanità (ISS), Italy (project No. 527/B/3A/4).Peer Reviewe

    Particulate matter exposure during pregnancy is associated with birth weight, but not gestational age, 1962-1992: a cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Exposure to air pollutants is suggested to adversely affect fetal growth, but the evidence remains inconsistent in relation to specific outcomes and exposure windows.</p> <p>Methods</p> <p>Using birth records from the two major maternity hospitals in Newcastle upon Tyne in northern England between 1961 and 1992, we constructed a database of all births to mothers resident within the city. Weekly black smoke exposure levels from routine data recorded at 20 air pollution monitoring stations were obtained and individual exposures were estimated via a two-stage modeling strategy, incorporating temporally and spatially varying covariates. Regression analyses, including 88,679 births, assessed potential associations between exposure to black smoke and birth weight, gestational age and birth weight standardized for gestational age and sex.</p> <p>Results</p> <p>Significant associations were seen between black smoke and both standardized and unstandardized birth weight, but not for gestational age when adjusted for potential confounders. Not all associations were linear. For an increase in whole pregnancy black smoke exposure, from the 1<sup>st </sup>(7.4 μg/m<sup>3</sup>) to the 25<sup>th </sup>(17.2 μg/m<sup>3</sup>), 50<sup>th </sup>(33.8 μg/m<sup>3</sup>), 75<sup>th </sup>(108.3 μg/m<sup>3</sup>), and 90<sup>th </sup>(180.8 μg/m<sup>3</sup>) percentiles, the adjusted estimated decreases in birth weight were 33 g (SE 1.05), 62 g (1.63), 98 g (2.26) and 109 g (2.44) respectively. A significant interaction was observed between socio-economic deprivation and black smoke on both standardized and unstandardized birth weight with increasing effects of black smoke in reducing birth weight seen with increasing socio-economic disadvantage.</p> <p>Conclusions</p> <p>The findings of this study progress the hypothesis that the association between black smoke and birth weight may be mediated through intrauterine growth restriction. The associations between black smoke and birth weight were of the same order of magnitude as those reported for passive smoking. These findings add to the growing evidence of the harmful effects of air pollution on birth outcomes.</p

    The Recognition Process in Dermoscopy: Analytic Approach vs Heuristic Approach

    Full text link

    Spitz Nevi

    No full text
    Few benign melanocytic lesions encountered in clinical practice elicit the level of controversy as that generated by lesions within the spectrum of Spitz nevi. Unlike melanoma, the dermoscopic structures found in Spitz nevi tend to be distributed in a symmetric and organized manner. This review highlights the melanoma-specific structures and patterns commonly seen in Spitz nevi. Knowledge of the dermoscopic structures and patterns encountered in Spitz nevi (particularly the classic symmetric starburst pattern), together with understanding of their growth dynamics, can inform the decision whether to biopsy or monitor
    corecore