590 research outputs found
Infrared spectroscopy of cataclysmic variables: III. Dwarf novae below the period gap and novalike variables
We present K-band spectra of the short-period dwarf novae YZ Cnc, LY Hya, BK
Lyn, T Leo, SW UMa and WZ Sge, the novalike variables DW UMa, V1315 Aql, RW
Tri, VY Scl, UU Aqr and GP Com, and a series of field dwarf stars with spectral
types ranging from K2-M6.
The spectra of the dwarf novae are dominated by emission lines of HI and HeI.
The large velocity and equivalent widths of these lines, in conjunction with
the fact that the lines are double-peaked in the highest inclination systems,
indicate an accretion disc origin. In the case of YZ Cnc and T Leo, for which
we obtained time-resolved data covering a complete orbital cycle, the emission
lines show modulations in their equivalent widths which are most probably
associated with the bright spot (the region where the gas stream collides with
the accretion disc). There are no clear detections of the secondary star in any
of the dwarf novae below the period gap, yielding upper limits of 10-30% for
the contribution of the secondary star to the observed K-band flux. In
conjunction with the K-band magnitudes of the dwarf novae, we use the derived
secondary star contributions to calculate lower limits to the distances to
these systems.
The spectra of the novalike variables are dominated by broad, single-peaked
emission lines of HI and HeI - even the eclipsing systems we observed do not
show the double-peaked profiles predicted by standard accretion disc theory.
With the exception of RW Tri, which exhibits NaI, CaI and 12CO absorption
features consistent with a M0V secondary contributing 65% of the observed
K-band flux, we find no evidence for the secondary star in any of the novalike
variables. The implications of this result are discussed.Comment: 13 pages, 5 figures, to appear in MNRA
UBVRI photopolarimetry of the long period eclipsing AM Herculis binary V1309
We report simultaneous UBVRI photo-polarimetric observations of the long
period (7.98 h) AM Her binary V1309 Ori. The length and shape of the eclipse
ingress and egress varies from night to night. We suggest this is due to the
variation in the brightness of the accretion stream. By comparing the phases of
circular polarization zero-crossovers with previous observations, we confirm
that V1309 Ori is well synchronized, and find an upper limit of 0.002 percent
for the difference between the spin and orbital periods. We model the
polarimetry data using a model consisting of two cyclotron emission regions at
almost diametrically opposite locations, and centered at colatitude 35 (deg)
and 145 (deg) on the surface of the white dwarf. We also present archive X-ray
observations which show that the negatively polarised accretion region is X-ray
bright.Comment: 11 pages, 12 figures (2 colour), Fig1 and Fig 4 are in lower
resolution than in original paper, accepted for publication in Monthly
Notices of the Royal Astronomical Societ
The Quiescent Spectrum of the AM CVn star CP Eri
We used the 6.5m MMT to obtain a spectrum of the AM CVn star CP Eri in
quiescence. The spectrum is dominated by He I emission lines, which are clearly
double peaked with a peak-to-peak separation of ~1900 km/s. The spectrum is
similar to that of the longer period AM CVn systems GP Com and CE 315, linking
the short and the long period AM CVn systems. In contrast with GP Com and CE
315, the spectrum of CP Eri does not show a central 'spike' in the line
profiles, but it does show lines of SiII in emission. The presence of these
lines indicates that the material being transferred is of higher metallicity
than in GP Com and CE 315, which, combined with the low proper motion of the
system, probably excludes a halo origin of the progenitor of CP Eri. We
constrain the primary mass to M_1>0.27 M_sun and the orbital inclination to 33
degr < i < 80 degr. The presence of the He I lines in emission opens up the
possibility for phase resolved spectroscopic studies which allows a
determination of the system parameters and a detailed study of helium accretion
disks under highly varying circumstances.Comment: 12 pages, 2 figures, accepted for publication in ApJ Letter
The secondary star and distance of the polar V1309 Ori
The first phase-resolved JHK light curves of the eclipsing polar (AM Herculis
binary) V1309 Ori are presented and interpreted. We separate the contributions
from the secondary star and from other sources with the aim of determining a
photometric distance. Simple model calculations show that the accretion stream
and the cyclotron source on the accreting white dwarf are minor contributors to
the infrared light, allowing an accurate determination of spectral type and
absolute flux of the secondary star. The unilluminated backside of the
secondary star as seen in eclipse has spectral type dM0 to dM0+. Its dereddened
magnitude is K = 13.58 at orbital phase phi = 0 (eclipse). Using the calibrated
surface brightness of M-stars and the published mass of the secondary, M2 =
0.46 Msun, we obtain a distance d = 600 +/- 25 pc which scales as M2^(1/2). The
radius of the Roche-lobe filling secondary exceeds the main-sequence radius of
an M0 star by 21 +11/-6 %. The debated origin of the infrared light of V1309
Ori has been settled in favor of the secondary star as the main contributor and
an accurate distance has been derived that will place estimates of the
luminosity and synchronization time scale on a more secure basis.Comment: 5 pages, 3 figures, accepted for publication in Astronomy and
Astrophysic
Investigation of the hydrodynamic properties of a new MRI-resistant programmable hydrocephalus shunt.
BACKGROUND: The Polaris valve is a newly released hydrocephalus shunt that is designed to drain cerebrospinal fluid (CSF) from the brain ventricles or lumbar CSF space. The aim of this study was to bench test the properties of the Polaris shunt, independently of the manufacturer. METHODS: The Polaris Valve is a ball-on-spring valve, which can be adjusted magnetically in vivo. A special mechanism is incorporated to prevent accidental re-adjustment by an external magnetic field. The performance and hydrodynamic properties of the valve were evaluated in the UK Shunt Evaluation Laboratory, Cambridge, UK. RESULTS: The three shunts tested showed good mechanical durability over the 3-month period of testing, and a stable hydrodynamic performance over 45 days. The pressure-flow performance curves, operating, opening and closing pressures were stable. The drainage rate of the shunt increased when a negative outlet pressure (siphoning) was applied. The hydrodynamic parameters fell within the limits specified by the manufacturer and changed according to the five programmed performance levels. Hydrodynamic resistance was dependant on operating pressure, changing from low values of 1.6 mmHg/ml/min at the lowest level to 11.2 mmHg/ml/min at the highest performance level. External programming proved to be easy and reliable. Even very strong magnetic fields (3 Tesla) were not able to change the programming of the valve. However, distortion of magnetic resonance images was present. CONCLUSION: The Polaris Valve is a reliable, adjustable valve. Unlike other adjustable valves (except the Miethke ProGAV valve), the Polaris cannot be accidentally re-adjusted by an external magnetic field.RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are
Recommended from our members
Laboratory study on "intracranial hypotension" created by pumping the chamber of a hydrocephalus shunt.
BACKGROUND: It has been reported that pumping a shunt in situ may precipitate a proximal occlusion, and/or lead to ventricular over-drainage, particularly in the context of small ventricles. In the laboratory we measured the effect of pumping the pre-chamber of hydrocephalus shunts on intracranial hypotension. MATERIALS AND METHODS: A simple physical model of the CSF space in a hydrocephalic patient was constructed with appropriate compliance, CSF production and circulation. This was used to test eleven different hydrocephalus shunts. The lowest pressure obtained, the number of pumps needed to reach this pressure, and the maximum pressure change with a single pump, were recorded. RESULTS: All models were able to produce negative pressures ranging from -11.5 mmHg (Orbis-Sigma valve) to -233.1 mmHg (Sinu-Shunt). The number of pumps required reaching these levels ranged from 21 (PS Medical LP Reservoir) to 315 (Codman Hakim-Programmable). The maximum pressure change per pump ranged from 0.39 mmHg (Orbis-Sigma valve) to 23.1 (PS Medical LP Reservoir). CONCLUSION: Patients, carers and professionals should be warned that 'pumping' a shunt's pre-chamber may cause a large change in intracranial pressure and predispose the patient to ventricular catheter obstruction or other complications.RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are
Ketamine-Induced Disruption of Verbal Self-Monitoring Linked to Superior Temporal Activation
Introduction: Misattribution of distorted self-generated speech in patients with schizophrenia has been associated with increased lateral temporal activation. As a pharmacological model of schizophrenia, we tested whether ketamine would induce the same effects in healthy individuals. Methods: Participants were 8 healthy male volunteers who were nave to ketamine (mean age: 28 years). Ketamine (0.23 mg/kg bolus followed by 0.64 mg/kg/h) and placebo infusions were administered in a double-blind, randomised order, during 2 functional magnetic resonance imaging (fMRI) sessions. Each fMRI session consisted of a verbal self-monitoring task in which auditory feedback was experimentally modified. Results: Ketamine was associated with psychotic and dissociative symptoms. Participants made more misattributions of distorted self-generated speech (p <0.02) during the ketamine infusion. Ketamine led to reduced activation in the left superior temporal cortex during self-distorted speech, regardless of whether the speech was identified correctly or not, as compared to the placebo infusion. Misidentification of speech that had been distorted was not associated with any increase in brain activation in during the placebo infusion, however ketamine-induced misattributions were associated with a relative increase in left superior temporal cortex activation. Discussion: These data are consistent with the notion that self-monitoring impairments underlie psychotic symptoms and suggest that N-methyl-D-aspartate (NMDA) receptor dysfunction may mediate self-monitoring deficits and psychotic phenomena in schizophrenia
- …