2,454 research outputs found
Investigating On-Orbit Attitude Determination Anomalies for the Solar Dynamics Observatory Mission
The Solar Dynamics Observatory (SDO) was launched on February 11, 2010 from Kennedy Space Center on an Atlas V launch vehicle into a geosynchronous transfer orbit. SDO carries a suite of three scientific instruments, whose observations are intended to promote a more complete understanding of the Sun and its effects on the Earth's environment. After a successful launch, separation, and initial Sun acquisition, the launch and flight operations teams dove into a commissioning campaign that included, among other things, checkout and calibration of the fine attitude sensors and checkout of the Kalman filter (KF) and the spacecraft s inertial pointing and science control modes. In addition, initial calibration of the science instruments was also accomplished. During that process of KF and controller checkout, several interesting observations were noticed and investigated. The SDO fine attitude sensors consist of one Adcole Digital Sun Sensor (DSS), two Galileo Avionica (GA) quaternion-output Star Trackers (STs), and three Kearfott Two-Axis Rate Assemblies (hereafter called inertial reference units, or IRUs). Initial checkout of the fine attitude sensors indicated that all sensors appeared to be functioning properly. Initial calibration maneuvers were planned and executed to update scale factors, drift rate biases, and alignments of the IRUs. After updating the IRU parameters, the KF was initialized and quickly reached convergence. Over the next few hours, it became apparent that there was an oscillation in the sensor residuals and the KF estimation of the IRU bias. A concentrated investigation ensued to determine the cause of the oscillations, their effect on mission requirements, and how to mitigate them. The ensuing analysis determined that the oscillations seen were, in fact, due to an oscillation in the IRU biases. The low frequencies of the oscillations passed through the KF, were well within the controller bandwidth, and therefore the spacecraft was actually following the oscillating biases, resulting in movement of the spacecraft on the order of plus or minus 20 arcsec. Though this level of error met the ACS attitude knowledge requirement of [35, 70, 70] arcsec, 3 sigma, the desire of the ACS and instrument teams was to remove as much of the oscillation as possible. The Kearfott IRUs have an internal temperature controller, designed to maintain the IRU temperature at a constant temperature of approximately 70 C, thus minimizing the change in the bias drift and scale factors of the mechanical gyros. During ground testing of the observatory, it was discovered that the 83-Hz control cycle of the IRU heaters put a tremendous amount of stress on the spacecraft battery. Analysis by the power systems team indicated that the constant charge/discharge on the battery due to the IRU thermal control cycle could potentially limit the life of the battery. After much analysis, the decision was made not to run the internal IRU heaters. Analysis of on orbit data revealed that the oscillations in the IRU bias had a connection to the temperature of the IRU; changes in IRU temperature resulted in changes in the amplitude and period of the IRU biases. Several mitigating solutions were investigated, the result of which was to tune the KF with larger IRU noise assumptions which allows the KF to follow and correct for the time-varying IRU biases
Aquilegia, Vol. 28 No. 3, May-June-July 2004: Newsletter of the Colorado Native Plant Society
https://epublications.regis.edu/aquilegia/1102/thumbnail.jp
Recommended from our members
T Oligo-Primed Polymerase Chain Reaction (TOP-PCR): A Robust Method for the Amplification of Minute DNA Fragments in Body Fluids.
Body fluid DNA sequencing is a powerful noninvasive approach for the diagnosis of genetic defects, infectious agents and diseases. The success relies on the quantity and quality of the DNA samples. However, numerous clinical samples are either at low quantity or of poor quality due to various reasons. To overcome these problems, we have developed T oligo-primed polymerase chain reaction (TOP-PCR) for full-length nonselective amplification of minute quantity of DNA fragments. TOP-PCR adopts homogeneous "half adaptor" (HA), generated by annealing P oligo (carrying a phosphate group at the 5' end) and T oligo (carrying a T-tail at the 3' end), for efficient ligation to target DNA and subsequent PCR amplification primed by the T oligo alone. Using DNA samples from body fluids, we demonstrate that TOP-PCR recovers minute DNA fragments and maintains the DNA size profile, while enhancing the major molecular populations. Our results also showed that TOP-PCR is a superior method for detecting apoptosis and outperforms the method adopted by Illumina for DNA amplification
Anxiety and Depression in Autistic College Students: The Freshman Survey Results
Objective
Mental health among undergraduate students is a growing concern in higher education, but relatively little is known about the mental health of autistic college students. In order to better understand the unique needs of this population, the present study examines whether demographic and psychosocial correlates of anxiety and depression differ in autistic first-year college students and their non-autistic peers.
Methods
Secondary data analysis was conducted utilizing population-weighted data of full-time college students in their first year attending four-year colleges and universities in 2016, 2018, and 2019. Autistic and non-autistic students who self-identified as having frequent anxiety or depression were compared in terms of demographic characteristics, physical and emotional health, and academic aspirations and achievement.
Results
The majority of first-year students with frequent anxiety or depression in this sample tended to be white and had parents who completed a bachelor's degree or went to graduate school, with higher rates of male students in the autistic group. While autistic college freshmen with frequent anxiety or depression self-report lower overall quality of physical health (below average or lowest 10% reported by 57.3% vs. 37.1%) and higher rates of learning disabilities (25.3% vs. 4.6%) and psychological disorders (62.3% vs. 29.3%), these students also tend to outperform their non-autistic peers on standardized academic testing.
Conclusion
As autistic students are investing in themselves through their education and future careers, practitioners and researchers alike should be investing in accessible physical and mental health services in order to help set autistic students up for success in college and beyond
Information and communication technology to link criminal justice reentrants to HIV care in the community
The United States has the world’s highest prison population, and an estimated one in seven HIV-positive persons in the USA passes through a correctional facility annually. Given this, it is critical to develop innovative and effective approaches to support HIV treatment and retention in care among HIV-positive individuals involved in the criminal justice (CJ) system. Information and communication technologies (ICTs), including mobile health (mHealth) interventions, may offer one component of a successful strategy for linkage/retention in care. We describe CARE+ Corrections, a randomized controlled trial (RCT) study now underway in Washington, that will evaluate the combined effect of computerized motivational interview counseling and postrelease short message service (SMS) text message reminders to increase antiretroviral therapy (ART) adherence and linkage and retention in care among HIV-infected persons involved in the criminal justice system. In this report, we describe the development of this ICT/mHealth intervention, outline the study procedures used to evaluate this intervention, and summarize the implications for the mHealth knowledge base
High expression FUT1 and B3GALT5 is an independent predictor of postoperative recurrence and survival in hepatocellular carcinoma.
Cancer may arise from dedifferentiation of mature cells or maturation-arrested stem cells. Previously we reported that definitive endoderm from which liver was derived, expressed Globo H, SSEA-3 and SSEA-4. In this study, we examined the expression of their biosynthetic enzymes, FUT1, FUT2, B3GALT5 and ST3GAL2, in 135 hepatocellular carcinoma (HCC) tissues by qRT-PCR. High expression of either FUT1 or B3GALT5 was significantly associated with advanced stages and poor outcome. Kaplan Meier survival analysis showed significantly shorter relapse-free survival (RFS) for those with high expression of either FUT1 or B3GALT5 (P = 0.024 and 0.001, respectively) and shorter overall survival (OS) for those with high expression of B3GALT5 (P = 0.017). Combination of FUT1 and B3GALT5 revealed that high expression of both genes had poorer RFS and OS than the others (P < 0.001). Moreover, multivariable Cox regression analysis identified the combination of B3GALT5 and FUT1 as an independent predictor for RFS (HR: 2.370, 95% CI: 1.505-3.731, P < 0.001) and OS (HR: 2.153, 95% CI: 1.188-3.902, P = 0.012) in HCC. In addition, the presence of Globo H, SSEA-3 and SSEA-4 in some HCC tissues and their absence in normal liver was established by immunohistochemistry staining and mass spectrometric analysis
Dome-Shaped Ellipsoidal Reflector Antenna for UHF-RFID Readers with Confined Near-Field Detection Region
This letter proposes and demonstrates the concept of ellipsoidal reflector antennas for radio frequency identification reader applications at UHF band. The antenna can be potentially integrated with environmental structures to confine the reader detection region. The energy bounding characteristics result from the dual-focus feature of an ellipsoidal reflector in its near-field region, as the feed located at one of the two foci can create a focused field distribution around the other focus. An axial energy focusing is, thus, formed to confine the energy in a restricted region (near-field beam focusing), also minimizing the interference effects outside of the targeted area. Both numerical simulations and experimental results are presented to demonstrate the feasibility of this antenna concept
Recommended from our members
Family-Centered Care: Current Applications and Future Directions in Pediatric Health Care
Family-centered care (FCC) is a partnership approach to health care decision-making between the family and health care provider. FCC is considered the standard of pediatric health care by many clinical practices, hospitals, and health care groups. Despite widespread endorsement, FCC continues to be insufficiently implemented into clinical practice. In this paper we enumerate the core principles of FCC in pediatric health care, describe recent advances applying FCC principles to clinical practice, and propose an agenda for practitioners, hospitals, and health care groups to translate FCC into improved health outcomes, health care delivery, and health care system transformation
Solar Dynamics Observatory On-Orbit Jitter Testing, Analysis, and Mitigation Plans
The Solar Dynamics Observatory (SDO) was designed to understand the Sun and the Sun s influence on Earth. SDO was launched on February 11, 2010 carrying three scientific instruments: the Atmospheric Imaging Assembly (AIA), the Helioseismic and Magnetic Imager (HMI), and the Extreme Ultraviolet Variability Experiment (EVE). Both AIA and HMI are sensitive to high frequency pointing perturbations and have sub-arcsecond level line-of-sight (LOS) jitter requirements. Extensive modeling and analysis efforts were directed in estimating the amount of jitter disturbing the science instruments. To verify the disturbance models and to validate the jitter performance prior to launch, many jitter-critical components and subassemblies were tested either by the mechanism vendors or at the NASA Goddard Space Flight Center (GSFC). Although detailed analysis and assembly level tests were performed to obtain good jitter predictions, there were still several sources of uncertainties in the system. The structural finite element model did not have all the modes correlated to test data at high frequencies (greater than 50 Hz). The performance of the instrument stabilization system was not known exactly but was expected to be close to the analytical model. A true disturbance-to-LOS observatory level test was not available due to the tight schedule of the flight spacecraft, the cost in time and manpower, difficulties in creating gravity negation systems, and risks of damaging flight hardware. To protect the observatory jitter performance against model uncertainties, the SDO jitter team devised several on-orbit jitter reduction plans in addition to reserve margins on analysis results. Since some of these plans severely restricted the capabilities of several spacecraft components (e.g. wheels and High Gain Antennas), the SDO team performed on-orbit jitter tests to determine which jitter reduction plans, if any, were necessary to satisfy science LOS jitter requirements. The SDO on-orbit jitter tests were designed to satisfy the following four objectives: 1. Determine the acceptable reaction wheel operational speed range during Science Mode. 2. Determine HGA algorithm jitter parameters (number of stagger steps and enable/disable no-steprequests). 3. Determine acceptable EVE instrument filter wheels spin rates. 4. Determine if AIA instrument filter wheels excite the first AIA telescope structural mode. This paper provides detailed information on the SDO wheel jitter test plan, shows on-orbit jitter measurements and how ground predictions compare to those measurements, and describes the final jitter mitigation plan executed on SDO
Determining Risk Factors That affect Progression in Patients With Nonproliferative Diabetic Retinopathy
PURPOSE: to determine risk factors that affect nonproliferative diabetic retinopathy (NPDR) progression and establish a predictive model to estimate the probability of and time to progression in NPDR.
RESULTS: Two hundred thirty patients were included. Initially, 65 eyes (28.3%) had no retinopathy; 73 (31.7%) mild NPDR; 60 (26.1%) moderate NPDR; and 32 (13.9%) severe NPDR. Patients were followed for a mean of 5.8 years (±2.0 years; range 2.1-9.4 years). 164 (71.3%) eyes progressed during the follow-up. Time-independent risk factors affecting progression rate were age (hazard ratio (HR) = 0.99,
CONCLUSION: HbA1c level is a significant modifiable risk factor in controlling the progression of DR. The proposed model could be used to predict the time and rate of progression based on an individual\u27s risk factors. A prospective multicenter study should be conducted to further validate our model
- …