12 research outputs found

    Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients

    Get PDF
    INTRODUCTION: Central venous cannulation is crucial in the management of the critical care patient. This study was designed to evaluate whether real-time ultrasound-guided cannulation of the internal jugular vein is superior to the standard landmark method. METHODS: In this randomised study, 450 critical care patients who underwent real-time ultrasound-guided cannulation of the internal jugular vein were prospectively compared with 450 critical care patients in whom the landmark technique was used. Randomisation was performed by means of a computer-generated random-numbers table, and patients were stratified with regard to age, gender, and body mass index. RESULTS: There were no significant differences in gender, age, body mass index, or side of cannulation (left or right) or in the presence of risk factors for difficult venous cannulation such as prior catheterisation, limited sites for access attempts, previous difficulties during catheterisation, previous mechanical complication, known vascular abnormality, untreated coagulopathy, skeletal deformity, and cannulation during cardiac arrest between the two groups of patients. Furthermore, the physicians who performed the procedures had comparable experience in the placement of central venous catheters (p = non-significant). Cannulation of the internal jugular vein was achieved in all patients by using ultrasound and in 425 of the patients (94.4%) by using the landmark technique (p < 0.001). Average access time (skin to vein) and number of attempts were significantly reduced in the ultrasound group of patients compared with the landmark group (p < 0.001). In the landmark group, puncture of the carotid artery occurred in 10.6% of patients, haematoma in 8.4%, haemothorax in 1.7%, pneumothorax in 2.4%, and central venous catheter-associated blood stream infection in 16%, which were all significantly increased compared with the ultrasound group (p < 0.001). CONCLUSION: The present data suggest that ultrasound-guided catheterisation of the internal jugular vein in critical care patients is superior to the landmark technique and therefore should be the method of choice in these patients

    Detection of abnormal left ventricular geometry in patients without cardiovascular disease through machine learning: An ECG‐based approach

    No full text
    Cardiac remodeling is recognized as an important aspect of cardiovascular disease (CVD) progression. Machine learning (ML) techniques were applied to basic clinical parameters and electrocardiographic features, in order to detect abnormal left ventricular geometry (LVG) even before the onset of left ventricular hypertrophy (LVH), in a population without established CVD. The authors enrolled 528 patients with and without essential hypertension, but no other indications of CVD. All patients underwent a full echocardiographic evaluation and were classified into 3 groups; normal geometry (NG), concentric remodeling without LVH (CR), and LVH. Abnormal LVG was identified as increased relative wall thickness (RWT) and/or left ventricular mass index (LVMi). The authors trained supervised ML models to classify patients with abnormal LVG and calculated SHAP values to perform feature importance and interaction analysis. Hypertension, age, body mass index over the Sokolow‐Lyon voltage, QRS‐T angle, and QTc duration were some of the most important features. Our model was able to distinguish NG from CR+LVH combined, with 87% accuracy on an unseen test set, 75% specificity, 97% sensitivity, and area under the receiver operating curve (AUC/ROC) equal to 0.91. The authors also trained our model to classify NG and CR (NG + CR) against those with LVH, with 89% test set accuracy, 93% specificity, 67% sensitivity, and an AUC/ROC value of 0.89, for a 0.4 decision threshold. Our ML algorithm effectively detects abnormal LVG even at early stages. Innovative solutions are needed to improve risk stratification of patients without established CVD, and ML may enable progress in this direction

    Androgen deficiency and endothelial dysfunction in men with end-stage kidney disease receiving maintenance hemodialysis

    No full text
    Two thirds of men with end-stage kidney disease (ESKD) have serum testosterone levels in the hypogonadal range. We examined if low serum testosterone levels were correlated with measures of endothelial dysfunction in ESKD. Bilateral common carotid artery (CCA) intima-media thickness (IMT) and atherosclerotic plaque occurrence, left ventricular mass index, flow- (FMD) and nitrate-mediated vasodilatation (NMD) of the brachial artery were determined by ultrasound imaging in 100 nondiabetic men with ESKD (50 men exhibited androgen deficiency; serum testosterone concentrations <300 ng/dl). Left-ventricular mass index, CCA diameter, CCA-IMT and atherosclerotic plaque occurrence were all significantly increased in ESKD patients with androgen deficiency compared with patients without androgen deficiency (p < 0.05). Also, FMD and NMD measurements were significantly reduced in the former compared with the latter (p < 0.05). Testosterone levels were inversely correlated with age and duration of hemodialysis therapy (r = -0.44 and r = -0.55; p < 0.001). Testosterone levels were negatively correlated to CCA-IMT and atherosclerotic plaque occurrence in patients with androgen deficiency (r = -0.32, p < 0.003, and r = -0.23, p < 0.04, respectively). FMD and NMD measurements were positively correlated to total (r = 0.65 and r = 0.61; both p < 0.0001) and free (r = 0.52 and r = 0.48; both p < 0.001) testosterone levels in patients with low androgenicity. The present results indicated that ESKD patients with androgen deficiency had increased CCA-IMT, atherosclerotic plaque occurrence and reduced FMD and NMD compared with patients without androgen deficiency. Testosterone serum levels were negatively correlated to CCA-IMT and positively correlated to endothelium-dependent vasodilatation in ESKD patients with androgen deficienc

    Eal-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients

    No full text
    Introduction Central venous cannulation is crucial in the management of the critical care patient. This study was designed to evaluate whether real-time ultrasound-guided cannulation of the internal jugular vein is superior to the standard landmark method. Methods In this randomised study, 450 critical care patients who underwent real-time ultrasound-guided cannulation of the internal jugular vein were prospectively compared with 450 critical care patients in whom the landmark technique was used. Randomisation was performed by means of a computer-generated random-numbers table, and patients were stratified with regard to age, gender, and body mass index. Results There were no significant differences in gender, age, body mass index, or side of cannulation ( left or right) or in the presence of risk factors for difficult venous cannulation such as prior catheterisation, limited sites for access attempts, previous difficulties during catheterisation, previous mechanical complication, known vascular abnormality, untreated coagulopathy, skeletal deformity, and cannulation during cardiac arrest between the two groups of patients. Furthermore, the physicians who performed the procedures had comparable experience in the placement of central venous catheters ( p = non-significant). Cannulation of the internal jugular vein was achieved in all patients by using ultrasound and in 425 of the patients (94.4%) by using the landmark technique ( p &lt; 0.001). Average access time ( skin to vein) and number of attempts were significantly reduced in the ultrasound group of patients compared with the landmark group ( p &lt; 0.001). In the landmark group, puncture of the carotid artery occurred in 10.6% of patients, haematoma in 8.4%, haemothorax in 1.7%, pneumothorax in 2.4%, and central venous catheter-associated blood stream infection in 16%, which were all significantly increased compared with the ultrasound group ( p &lt; 0.001). Conclusion The present data suggest that ultrasound-guided catheterisation of the internal jugular vein in critical care patients is superior to the landmark technique and therefore should be the method of choice in these patients
    corecore