66 research outputs found

    Beam hardening artifact reduction using dual energy computed tomography: implications for myocardial perfusion studies

    Get PDF
    Background: Myocardial perfusion computed tomography (CTP) using conventional single energy (SE) imaging is influenced by the presence of beam hardening artifacts (BHA), occasionally resembling perfusion defects and commonly observed at the left ventricular posterobasal wall (PB). We therefore sought to explore the ability of dual energy (DE) CTP to attenuate the presence of BHA. Methods: Consecutive patients without history of coronary artery disease who were referred for computed tomography coronary angiography due to atypical chest pain and a normal stress-rest SPECT and had absence or mild coronary atherosclerosis constituted the study population. The study group was acquired using DE and the control group using SE imaging. Results: Demographical characteristics were similar between groups, as well as the heart rate and the effective radiation dose. Myocardial signal density (SD) levels were evaluated in 280 basal segments among the DE group (140 PB segments for each energy level from 40 keV to 100 keV; and 140 reference segments), and in 40 basal segments (at the same locations) among the SE group. Among the DE group, myocardial SD levels and myocardial SD ratio evaluated at the reference segment were higher at low energy levels, with significantly lower SD levels at increasing energy levels. Myocardial signal-to-noise ratio was not significantly influenced by the energy level applied, although 70 keV was identified as the energy level with the best overall signal-to-noise ratio. Significant differences were identified between the PB segment and the reference segment among the lower energy levels, whereas at ≥ 70 keV myocardial SD levels were similar. Compared to DE reconstructions at the best energy level (70 keV), SE acquisitions showed no significant differences overall regarding myocardial SD levels among the reference segments. Conclusions: Beam hardening artifacts that influence the assessment of myocardial perfusion can be attenuated using DE at 70 keV or higher.Fil: Rodriguez Granillo, Gaston Alfredo. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Cardiológicas. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Investigaciones Cardiológicas; Argentina. Diagnóstico Maipú; ArgentinaFil: Carrascosa, Patricia. Diagnóstico Maipú; ArgentinaFil: Cipriano, Silvia. Diagnóstico Maipú; ArgentinaFil: De Zan, Macarena. Diagnóstico Maipú; ArgentinaFil: Deviggiano, Alejandro. Diagnóstico Maipú; ArgentinaFil: Capunay, Carlos. Diagnóstico Maipú; ArgentinaFil: Cury, Ricardo C.. Miami Cardiac and Vascular Institute and Baptist Health; Estados Unido

    Thoracic aorta cardiac-cycle related dynamic changes assessed with a 256-slice CT scanner

    Get PDF
    Objective: The aim of our study was to demonstrate whether the dynamic changes previously documented at the ascending and abdominal aorta are replicated at the thoracic aorta. Methods and results: A consecutive series of thirty patients referred to our institution to undergo CT angiography of the thoracic aorta (CTA) constituted the study population. Patients with diffuse aortic atherosclerosis were excluded from the analysis. All studies were acquired with a 256-MDCT scanner and ECG-gating was performed in all cases. Two orthogonal imaging planes (maximal and minimal diameters) were obtained at three different levels of the descending thoracic aorta, using the distance from the left subclavian artery as proximal landmark: 10, 40, and 80 mm distance. The mean age was 58.9±15.7 years and 16 (53%) patients were male. Descending aorta measurements at 10, 40, and 80 mm distance from the left subclavian artery were all significantly larger within the systolic window (P<0.01 for all comparisons). Measurements of the maximal diameter were systematically larger than the minimal diameters among all aortic positions including ungated, systolic, and diastolic measurements (P<0.05 for all comparisons). Conclusions: The main finding of our pilot investigation was that the thoracic descending aorta undergoes significant conformational changes during the cardiac cycle, irrespective from the distance from the left subclavian artery.Fil: Carrascosa, Patricia. Diagnóstico Maipú; ArgentinaFil: Capuñay, Carlos. Diagnóstico Maipú; ArgentinaFil: Deviggiano, Alejandro. Diagnóstico Maipú; ArgentinaFil: Rodriguez Granillo, Gaston Alfredo. Diagnóstico Maipú; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Sagarduy, María Inés. Diagnóstico Maipú; ArgentinaFil: Cortines, Patricio. Diagnóstico Maipú; ArgentinaFil: Carrascosa, Jorge. Diagnóstico Maipú; ArgentinaFil: Parodi, Juan C.. Sanatorio Trinidad; Argentin

    Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease

    Get PDF
    We explored whether intracycle motion correction algorithms (MCAs) might be applicable to dual energy computed tomography coronary angiography in patients with intermediate to high likelihood of coronary artery disease. MCA reconstructions were associated with higher interpretability rates (96.7% vs 87.9%, P < .001), image quality scores (4.12±0.9 vs. 3.76±1.0; P < .0001), and diagnostic performance [area under the curve of 0.95 (95% confidence interval [CI] 0.92-0.97) vs 0.89 (95% CI 0.86-0.92); P < .0001] compared to conventional reconstructions. In conclusion, application of intracycle MCA reconstructions to dual energy computed tomography acquisitions was feasible and resulted in significantly higher image quality scores, interpretability, and diagnostic performance.Fil: Carrascosa, Patricia. Diagnóstico Maipú; ArgentinaFil: Deviggiano, Alejandro. Diagnóstico Maipú; ArgentinaFil: Leipsic, Jonathon A.. St. Paul's Hospital; CanadáFil: Capunay, Carlos. Diagnóstico Maipú; ArgentinaFil: De Zan, Macarena C.. Diagnóstico Maipú; ArgentinaFil: Goldsmit, Alejandro. Sanatorio Güemes; ArgentinaFil: Rodriguez Granillo, Gaston Alfredo. Diagnóstico Maipú; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Cardiológicas. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Investigaciones Cardiológicas; Argentin

    Myocardial signal density levels and beam-hardening artifact attenuation using dual-energy computed tomography

    Get PDF
    The assessment of myocardial perfusion using single-energy (SE) imaging is influenced by beam-hardening artifacts (BHA). We sought to explore the ability of dual-energy (DE) imaging to attenuate the presence of BHA. Myocardial signal density (SD) was evaluated in 2240 myocardial segments (112 for each energy level) and in 320 American Heart Association segments among the SE group. Compared to DE reconstructions at the best energy level, SE acquisitions showed no significant differences overall regarding myocardial SD or signal-to-noise ratio. The segments most commonly affected by BHA showed significantly lower myocardial SD at the lowest energy levels, progressively normalizing at higher energy levels.Fil: Rodriguez Granillo, Gaston Alfredo. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Cardiológicas. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Investigaciones Cardiológicas; Argentina. Diagnóstico Maipú; ArgentinaFil: Carrascosa, Patricia. Diagnóstico Maipú; ArgentinaFil: Cipriano, Silvina. Diagnóstico Maipú; ArgentinaFil: de Zan, Macarena. Diagnóstico Maipú; ArgentinaFil: Deviggiano, Alejandro. Diagnóstico Maipú; ArgentinaFil: Capunay, Carlos. Diagnóstico Maipú; ArgentinaFil: Cury, Ricardo C.. Miami Cardiac and Vascular Institute; Estados Unidos. Baptist Health of South Florida; Estados Unido

    Nacimiento anómalo de la arteria coronaria izquierda desde el tronco de la arteria pulmonar con isquemia miocárdica e insuficiencia mitral

    Get PDF
    We present the case of a patient with a diagnosis of anomalous origin of the left coronary artery from the trunk of the pulmonary artery (ALCAPA). The patient had a previous diagnosis of asymptomatic severe mitral regurgitation of unknown cause. The unexpected evidence of ischemia in the anterior and apical territoryin the stress echocardiogram requested for functional evaluation in addition to the characteristic echocardiographic signs suggested the presumptive diagnosis of ALCAPA, which was confirmed with non-invasive coronary CT. Among the few patients with ALCAPA who reach adulthood, myocardial ischemia as initial presentation is rarePresentamos el caso de una paciente con diagnóstico de nacimiento anómalo de la arteria coronaria izquierda desde el tronco de la arteria pulmonar (ALCAPA). Se trata de una paciente joven con diagnóstico de insuficiencia mitral severa asintomática de causa no esclarecida. La inesperada evidencia de isquemia en territorio anterior y apical en el ecocardiograma de estrés solicitado para evaluación funcional sumado a los signos característicos del ecocardiograma sugirió el diagnóstico presuntivo de ALCAPA, que se confirmó con angiotomografía coronaria. Entre los pocos pacientes con ALCAPA que alcanzan la vida adulta, la isquemia miocárdica como presentación inicial es poco frecuente

    International Impact of COVID-19 on the Diagnosis of Heart Disease

    Get PDF
    BACKGROUND The coronavirus disease 2019 (COVID-19) pandemic has adversely affected diagnosis and treatment of noncommunicable diseases. Its effects on delivery of diagnostic care for cardiovascular disease, which remains the leading cause of death worldwide, have not been quantified.OBJECTIVES The study sought to assess COVID-19`s impact on global cardiovascular diagnostic procedural volumes and safety practices.METHODS The International Atomic Energy Agency conducted a worldwide survey assessing alterations in cardiovascular procedure volumes and safety practices resulting from COVID-19. Noninvasive and invasive cardiac testing volumes were obtained from participating sites for March and April 2020 and compared with those from March 2019. Availability of personal protective equipment and pandemic-related testing practice changes were ascertained.RESULTS Surveys were submitted from 909 inpatient and outpatient centers performing cardiac diagnostic procedures, in 108 countries. Procedure volumes decreased 42% from March 2019 to March 2020, and 64% from March 2019 to April 2020. Transthoradc echocardiography decreased by 59%, transesophageat echocardiography 76%, and stress tests 78%, which varied between stress modalities. Coronary angiography (invasive or computed tomography) decreased 55% (p &lt; 0.001 for each procedure). hi multivariable regression, significantly greater reduction in procedures occurred for centers in countries with lower gross domestic product. Location in a low-income and lower-middle-income country was associated with an additional 22% reduction in cardiac procedures and less availability of personal protective equipment and teteheatth.CONCLUSIONS COVID-19 was associated with a significant and abrupt reduction in cardiovascular diagnostic testing across the globe, especially affecting the world's economically challenged. Further study of cardiovascular outcomes and COVID-19-related changes in care delivery is warranted. (C) 2021 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    Cardiovascular CTA: Contrast, Concepts, Protocols

    Full text link
    corecore