102 research outputs found

    Aislamiento, cultivo e identificación de microorganismos ambientales a partir de muestras naturales

    Get PDF
    Se emplearán muestras naturales (agua, suelo, sedimentos de ríos o lagos, heces, etc.) a partir de las cuales se aislaran microrganismos cultivables, principalmente bacterias, mediante el empleo de medios selectivos. Posteriormente se procederá a la identificación por características morfológicas y patrones fisiológicos particulares.Fil: Moreno, Julio Ricardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucumán. Planta Piloto de Procesos Industriales Microbiológicos (i); Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Naturales e Instituto Miguel Lillo; ArgentinaFil: Albarracín, Virginia Helena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucumán. Planta Piloto de Procesos Industriales Microbiológicos (i); Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Naturales e Instituto Miguel Lillo; Argentin

    Photovoltaic reactive power limits

    Get PDF
    Today, Photovoltaic (PV) inverters are working with very small values of reactive power. Then, the Power Factor (PF) is very close to the unit. So, the PV installations only inject active power into the grid. This paper aims to investigate the limits of reactive power capacity in PV generators. In this way, PV generators could be used as a controlled reactive power sources. In this paper, an introduction to the voltage control in photovoltaic generators is described and implemented in Simulink/Matlab and PSS/E.The Spanish Ministry of Education and Science has supported this research under contract ENE2009-13883-C02-C1.Publicad

    Power Quality in distribution power networks with photovoltaic energy sources

    Get PDF
    Solar radiation is characterized by short fluctuations introduced by passing clouds. These solar fluctuations will produce Voltage and power fluctuations at the PCC (Point of common coupling). Flicker level should be evaluated by using a flickermeter according to the standard IEC 61000-4-15. Models of the solar fluctuation, photovoltaic modules and power converter are shown in this paper and the flickermeter model is tested according to the IEC requirements and the CIGRE/CIRED/UIE test protocol.This research has been partially supported by the Spanish Ministry of Education and Science under contracts ENE2006- 28503 and ENE2008-06504-C02-01.Publicad

    Cálculo técnico, energético y de viabilidad económica de instalación fotovoltaica de 100 kw conectada a red en edificio industrial

    Get PDF
    El presente documento contiene el proyecto técnico para la construcción de un generador fotovoltaico de 100 kW conectado a la red eléctrica, situado en la cubierta de un edificio industrial ubicado en Madrid, con tejado de nueva construcción. El punto de conexión a la red eléctrica está acordado con la Compañía distribuidora. La energía eléctrica producida por la central solar fotovoltaica se inyecta en la línea trifásica de baja tensión (230 /400 V) mediante la utilización de un único inversor trifásico, el cuál se situará en la planta inferior de la cubierta, para que se encuentre protegido de la humedad, así como elementos de protección. El sistema fotovoltaico de 100 kW consta esencialmente de: a) Un campo de paneles fotovoltaicos (generador fotovoltaico) de 124,2 kWp b) Un inversor trifásico de 100 kW. Se siguen las recomendaciones específicas del Pliego de Condiciones Técnicas de Instalaciones Conectadas a Red del I.D.A.E.Ingeniería Técnica en Electricida

    Medida de descargas parciales en radiofrecuencia

    Get PDF
    La detección de la actividad de Descargas Parciales (DPs) es de gran importancia para establecer cuál es el estado del aislamiento eléctrico de un equipo y poder aplicar un mantenimiento basado en la condición del mismo, condition-based maintenance. El método más común de medida de DPs es el eléctrico, en el que se miden pequeños cambios en la corriente que se fuga a tierra cuando se producen DPs en el equipo. En este sentido, se utilizan los esquemas propuestos en la norma (IEC-60270, 2000) en los que, se conecta a tierra un objeto de ensayo de DPs, considerado como una capacidad, a través de un condensador de acoplamiento. En el camino a tierra, se instala un equipo de medida de corriente y se aplica alta tensión al circuito, para adquirir la propagación del pulso. A partir de las medidas del pulso de DP, se puede identi car el tipo de fuente y hacer una clasi cación de las medidas en descargas internas, super ciales y corona. En los últimos años, con la extensión de las subestaciones en aislamiento de gas, Gas-Insulated Substation (GIS), se han popularizado los métodos de medida de la radiación en ultra-alta frecuencia, Ultra-High Frequency (UHF), emitida por la DP mediante el uso de antenas. Estas adquisiciones, se realizan en instalaciones de GIS debido a que en este tipo de subestaciones con gas a presión las emisiones de DPs pueden tener energía a frecuencias del orden de giga-hercios. En la actualidad, se está dando el salto a la utilización de esta misma tecnología en transformadores y líneas de alta tensión. Al ser una técnica novedosa, de hecho sus procedimientos de medida se publicarán previsiblemente en 2015 en la norma (IEC-62478, pendiente de publicación), quedan muchos aspectos por conocer y resolver, y algunos se abordan en esta tesis doctoral. Como aproximación, por un lado, es necesario establecer la relación que existe entre el pulso de radiación que mide la antena y el tipo de DP. Para ello, hay que aislar los distintos tipos de pulsos, utilizando objetos de ensayo que generen sólo un tipo de DP y, a continuación, caracterizar el pulso en el tiempo y en frecuencia para encontrar una correlación entre el tipo de descarga, su espectro de potencia en frecuencia y su forma de onda en el tiempo. Además, cuando se realiza la medida de los pulsos de DPs en Radiofrecuencia (RF) en el rango de muy alta frecuencia, Very-High Frequency (VHF), y UHF (30 3000 MHz), es de vital importancia separar las posibles fuentes de interferencia electromagnética de la radiación emitida por la fuente de DPs. Estas fuentes son: radio en frecuencia modulada, Frequency Modulated (FM), radio difusión sonora digital, Televisión (TV), sistema global para las comunicaciones móviles, Global System for Mobile Communications (GSM), delidad inalámbrica, Wireless-Fidelity (Wi-Fi), etc. Por otro lado, también se pueden aplicar las técnicas de medición de DPs en VHF y UHF para la monitorización del estado del aislamiento de uno de los activos más importantes de una red eléctrica, como son los transformadores de potencia. La mayor parte de los transformadores de gran potencia tienen un depósito denominado tanque o cuba en el que se alojan las columnas del material electromagnético, los arrollamientos y el sistema de aislamiento, todos ellos embebidos en aceite. El sumergir todos estos elementos en aceite, tiene como n reducir la temperatura y servir como aislante eléctrico para evitar fallos del sistema de aislamiento de los transformadores de potencia. Además, separan los arrollamientos del equipo, en cuyo sistema de aislamiento pueden haber imperfecciones cuyo origen es debido a su construcción, puesta en servicio o al funcionamiento del transformador. En estas imperfecciones, pueden originarse DPs que pueden dar lugar al fallo en el equipo si se produce una rotura del aislamiento y, en consecuencia, una descarga total. Para poder medir la actividad de DPs, es de vital importancia conocer cómo se propagan electromagnéticamente dentro del tanque de un transformador. Este recinto, se comporta como una cavidad resonante en el que se excitan ondas estacionarias que activan unas determinadas frecuencias de resonancia dependientes de la geometría del mismo. Una vez conocido el espectro electromagnético dentro del tanque, se estudiará la medida del mismo efecto desde fuera. De esta manera, se pueden conocer el efecto de su blindaje sobre las frecuencias que atenúa, así como las frecuencias que deja pasar. En esta tesis, se aborda el estudio de la radiación electromagnética emitida por las DPs, su parametrización y la selección de antenas para la correcta medida de fuentes de DPs. Además, se considera el efecto de la distancia en su adquisición y se comparan las respuestas del sistema de medida utilizado compuesto por un osciloscopio con la de un analizador de espectros comercial PDS-100. Por otro lado, se identi can los modos de resonancia propios de un modelo de cuba de transformador, así como de su in uencia en la propagación electromagnética de las DPs. Para esto, se preparan y seleccionan los objetos de ensayo que experimentalmente reproducen la emisión de DPs internas, super ciales y corona. Por último, se realiza un programa que permite el post-procesado de las señales adquiridas para el estudio posterior de los resultados obtenidos que darán lugar a interesantes conclusiones a partir de los mismos. -----------------------------------------------------------------------------------------------The detection of partial discharges (PD) activity is crucial to establish which is the status of insulation systems in electrical equipments and to ensure an e ective condition-based maintenance of electrical assets. The electrical measurements of PD is the most widely method used to detect possible failures. With this method, it is possible to measure short uctuations in the current leaked to ground when PD are produced in equipments. In this sense, the proposed schemes by the (IEC-60270, 2000) standard are used. In which, a current measuring equipment is connected to a partial discharge test object, considered as a capacity, and high-voltage is applied to the circuit to acquire pulse propagation through a coupling capacitor connected to ground. From partial discharge pulse measures, it can be identify the type of pulse, as well as the classi cation of the measures in internal discharges, surface and corona could be done. During the last years, the extended use of Gas-Insulated Substation (GIS) have led to the increase of popularity of methods for measuring the partial discharge emission in radio-frequency by antennas. These measurements are taken in GIS due to the fact that, in this kind of subsatations with pressurized gas, PD emissions can send out energy at frequencies in the order of giga-hertz. Currently, it is being made the leap to the use of the same technique in power transformers and power lines. As it is a new technique, in fact their measurement procedures will be published in (IEC-62478, not set published) standard in 2015, there are many aspects to be known about it and to be solved; therefore, some of them are addressed in this thesis. As an approach to this novel technique, on the one hand, it is necessary to establish the relationship between radiation pulse measured by the antenna and the type of partial discharge. This requires to isolate the di erent kinds of pulses using test objects that only generate one type of partial discharge, and then characterize the pulse in time and frequency domains so as to nd a correlation between the kind of discharge, its power frequency spectrum, and its waveform in time domain. Furthermore, when the partial discharge measurement is performed in RF at the VHF and UHF bands (30 3000 MHz) through the use of antennas, it is crucial to separate electromagnetic interferences from the electromagnetic radiation emitted by the partial discharge sources. These noise sources are: FM radio, television, GSM, Wi-Fi, etc. On the other hand, PD measurement techniques by using antennas can also be applied in insulation condition monitoring on one of the most important assets in a power grid as is the power transformer. Most of high-power transformers have a reservoir called tank in wich the columns of the electromagnetic material, the insulation system and the windings are found. All of them are inmerse in oil, that is used to reduce the temperature inside the tank and serve as an electrical insulator to prevent transformer insulation failures. This insulation systems, that separate the winding transformer, might have imperfections due to their construction, commisioning or caused by the transformer operation. In these weak points of the insulation system PD may be occur, it could trigger the failure of the equipment when the insulation is broken that provoke a total discharge. In this sense, it is crucial to know how electromagnetic waves caused by the PD are propagated inside a transformer tank. A tank behaves like a resonant cavity which allows the excitement of stationary waves which activate certain resonant frequencies depending on its own geometry. Known the characteristic of the electromagnetic propagation inside the tank, the same e ect will be studied from outside the cavity. By this way, the frequencies that are attenuated by the shielding can be detected. This thesis deals with the study of the electromagnetic radiation emitted by PD, its parametrization and the selection of proper antennas for measuring PD sources. Moreover, the distance e ect on the PD acquisition is also considered and the responses of the two acquisition systems, compounds by the oscilloscope and a commercial spectrum analyzer PDS-100 respectively, will be compared. On the other hand, will be obtained the identi cation of the resonance modes characteristic of a transformer tank model and its in uence on the electromagnetic emission of the PD. With this aim, test objects that reproduce experimentally PD are prepared and selected. This kind of PD are internal, surface and corona types. Finally, it is executed a program that allows the post-processing of the acquired signals for further study of the results obtained that will lead to interesting conclusions from them.Presidente: Miguel Ángel Sánchez-Urán Fernández; Vocal: Pedro Llovera Segovia; Secretaria: María Belén García de Burgo

    Diseño de la arquitectura hardware de un aerogenerador de velocidad variable DFIG

    Get PDF
    El presente proyecto tiene por objetivo el diseño y control de un prototipo de aerogenerador de velocidad variable doblemente alimentado en el laboratorio de la Universidad Carlos III utilizando una arquitectura hardware de bajo coste. El hardware implementado debe facilitar el control en tiempo real del prototipo del aerogenerador. Por lo que los tiempos de ejecución y muestreo son críticos. El prototipo de aerogenerador utilizado ha sido una bancada de motores que consta de un motor de corriente continua unido por un eje a un motor de corriente alterna. Para el control del aerogenerador en tiempo real se utilizará la aplicación xPC Target de The Mathworks, la cual permite trabajar en tiempo real. Se utilizarán tarjetas de adquisición de datos de National Instruments, SCB-68 y SCB-100 que permiten adquirir entradas y salidas: digitales y analógicas del sistema real y controlar los inversores del aerogenerador DFIG. Durante el presente proyecto se tendrá en cuenta la posibilidad de la utilización de una tarjeta DSP del fabricante Texas Instruments Spectrum Digital de modelo comercial eZDSPTM F2812. Esta tarjeta permite obtener cálculos en tiempo real comparables a los ofrecidos con la aplicación xPC Target. El empleo de la aplicación xPC Target nos permite la reutilización de CPUs, ordenadores antiguos en desuso, para el cálculo de procesos en tiempo real. Permitiendo tener un coste relativamente bajo mediante una implementación común de hardware innovador para la conexión y comunicación entre un sistema real que se pueda controlar en tiempo real.Ingeniería Industria

    Compensación de sobretensiones en redes eléctricas con generadores fotovoltaicos

    Get PDF
    El presente documento está estructurado según sigue. En el capítulo 1 se hace una exposición sobre el estado del arte referente al problema de sobretensiones que presentan los sistemas eléctricos con presencia de generadores fotovoltaicos. En el capítulo 2 se explica brevemente qué se entiende por energía solar fotovoltaica y se presenta un estudio detallado sobre recurso solar. En el capítulo 3 se presenta el modelo completo de un sistema fotovoltaico conectado a la red eléctrica y se explica el funcionamiento del control de tensión en la red. Además, se detallan los elementos y se modelan cada una de las partes que componen al sistema fotovoltaico conectado a la red. En el capítulo 4 se estudia en detalle la capacidad de generación/absorción de potencia reactiva que ofrecen los generadores fotovoltaicos conectados a la red eléctrica. En el capítulo 5, se presentan las simulaciones y resultados obtenidos. Por último, se finaliza el documento presentando el capítulo 6 con las principales conclusiones y aportaciones. Y se finaliza el documento con el capítulo 7, trabajos futuros a realizar.Máster universitario en Ingeniería Eléctrica, Electrónica y Automática. 1ª edición. Curso académico 2009/201

    Aspectos ecológicos y metodológicos del muestreo, identificación y cuantificación de cianobacterias y microalgas eucariotas

    Get PDF
    Mediante el muestreo de un cuerpo de agua, empleando red de plancton, obtendremos muestras de cianobacterias y microalgas eucariotas. Una vez realizada la identificación taxonómica, se realizarán análisis cualitativos y cuantitativos de los mismos para determinar la riqueza y abundancia de especies presentes. Finalmente, con parte de las muestras colectadas, extraeremos y cuantificaremos los pigmentos fotosintéticos para comparar los resultados obtenidos con los del análisis cuantitativo.Fil: Moreno, Julio Ricardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucumán. Planta Piloto de Procesos Industriales Microbiológicos (i); Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Naturales e Instituto Miguel Lillo; ArgentinaFil: Medina, César Dante. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucumán. Planta Piloto de Procesos Industriales Microbiológicos (i); Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Naturales e Instituto Miguel Lillo; ArgentinaFil: Albarracín, Virginia Helena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucumán. Planta Piloto de Procesos Industriales Microbiológicos (i); Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Naturales e Instituto Miguel Lillo; Argentin

    Shielding effect of power transformers tanks in the ultra-high-frequency detection of partial discharges

    Get PDF
    Partial discharges (PD) measurement is a well-known technique for judgment of the condition of power transformer offline. Phase-resolved PD measurement is a normalized technique for PD tests, but noise, especially by PD-measurements onsite is sometimes difficult to reject, and a post-processing of a pattern is necessary to separate different sources. Higher-frequency-detection devices and processing strategies are useful for PD classification and identification. Recently, ultra-high-frequency (UHF) detection by means of antennas has been shown to be a promising detection system for both offline and online PD-measurements. However, it is necessary to assess whether PD source separation and classification is possible by means of pulse analysis because some additional UHF noise sources are coupled to the detected signals, and it is not clear whether different sources produce different pulses. In this study, the attenuation effect of the metallic tank of a power transformer on the inner PD activity when measured outside the tank was studied. Additionally, experiments were conducted to detect and characterize two different PD sources (internal and external discharges) using two antennas measuring the same phenomenon inside and outside of a transformer. It will also be shown that broadband UHF signals are useful for PD recognition and that a deep study of frequencies below 500 MHz can separate PD occurring inside from those occurring outside when measured with an antenna outside the tank.This research has been supported by the Spanish Science and Technology Ministry under contract DPI 2009-14628- C03-02 and by the Madrid Regional Government and Universidad Carlos III de Madrid under contract CCG10- UC3M/DPI-4627. Tests have been made in the High Voltage Research and Tests Laboratory of Universidad Carlos III de Madrid (LINEALT).Publicad

    A New Switching Impulse Generator Based on Transformer Boosting and Insulated Gate Bipolar Transistor Trigger Control

    Get PDF
    To make the switching impulse (SI) generator more compact, portable and feasible in field tests, a new approach based on transformer boosting was developed. To address problems such as triggering synchronization and electromagnetic interference involved with the traditional spark gap, an insulated gate bipolar transistor (IGBT) module with drive circuit was employed as the impulse trigger. An optimization design for the component parameters of the primary winding side of the transformer was realized by numerical calculation and error correction. Experiment showed that the waveform parameters of SI and oscillating switching impulse (OSI) voltages generated by the new generator were consistent with the numerical calculation and the error correction. The generator was finally built on a removable high voltage transformer with small size. Thus the volume of the generator is significantly reduced. Experiments showed that the waveform parameters of SI and OSI voltages generated by the new generator were basically consistent with the numerical calculation and the error correction
    corecore