29 research outputs found

    Effect of mattress deflection on CPR quality assessment for older children and adolescents

    Get PDF
    Appropriate chest compression (CC) depth is associated with improved CPR outcome. CCs provided in hospital are often conducted on a compliant mattress. The objective was to quantify the effect of mattress compression on the assessment of CPR quality in children. Methods: A force and deflection sensor (FDS) was used during CPR in the Pediatric Intensive Care Unit and Emergency Department of a children's hospital. The sensor was interposed between the chest of the patient and hands of the rescuer and measured CC depth. Following CPR event, each event was reconstructed with a manikin and an identical mattress/backboard/patient configuration. CCs were performed using FDS on the sternum and a reference accelerometer attached to the spine of the manikin, providing a means to Calculate the mattress deflection. Results: Twelve CPR events with 14,487 CC (11 patients, median age 14.9 years) were recorded and reconstructed: 9 on ICU beds (9296 CC), 3 on stretchers (5191 CC). Measured mean CC depth during CPR was 47 +/- 8 mm on ICU beds, and 45 +/- 7 mm on stretcher beds with overestimation of 13 +/- 4 mm and 4 +/- 1 mm, respectively, due to mattress compression. After adjusting for this, the proportion of CC that met the CPR guidelines decreased from 88.4 to 31.8% on ICU beds (p < 0.001), and 86.3 to 64.7% on stretcher (p < 0.001 The proportion of appropriate depth CC was significantly smaller on ICU beds (p < 0.001). Conclusion: CC conducted on a non-rigid surface may not be deep enough. FDS may overestimate CC depth by 28% on ICU beds, and 10% on stretcher beds

    Community-based in situ simulation: bringing simulation to the masses

    Get PDF
    Simulation-based methods are regularly used to train inter-professional groups of healthcare providers at academic medical centers (AMC). These techniques are used less frequently in community hospitals. Bringing in-situ simulation (ISS) from AMCs to community sites is an approach that holds promise for addressing this disparity. This type of programming allows academic center faculty to freely share their expertise with community site providers. By creating meaningful partnerships community-based ISS facilitates the communication of best practices, distribution of up to date policies, and education/training. It also provides an opportunity for system testing at the community sites. In this article, we illustrate the process of implementing an outreach ISS program at community sites by presenting four exemplar programs. Using these exemplars as a springboard for discussion, we outline key lessons learned discuss barriers we encountered, and provide a framework that can be used to create similar simulation programs and partnerships. It is our hope that this discussion will serve as a foundation for those wishing to implement community-based, outreach ISS

    Differences in the Quality of Pediatric Resuscitative Care Across a Spectrum of Emergency Departments

    Get PDF
    Importance: The quality of pediatric resuscitative care delivered across the spectrum of emergency departments (EDs) in the United States is poorly described. In a recent study, more than 4000 EDs completed the Pediatric Readiness Survey (PRS); however, the correlation of PRS scores with the quality of simulated or real patient care has not been described. Objective: To measure and compare the quality of resuscitative care delivered to simulated pediatric patients across a spectrum of EDs and to examine the correlation of PRS scores with quality measures. Design, Setting, and Participants: This prospective multicenter cohort study evaluated 58 interprofessional teams in their native pediatric or general ED resuscitation bays caring for a series of 3 simulated critically ill patients (sepsis, seizure, and cardiac arrest). Main Outcomes and Measures: A composite quality score (CQS) was measured as the sum of 4 domains: (1) adherence to sepsis guidelines, (2) adherence to cardiac arrest guidelines, (3) performance on seizure resuscitation, and (4) teamwork. Pediatric Readiness Survey scores and health care professional demographics were collected as independent data. Correlations were explored between CQS and individual domain scores with PRS. Results: Overall, 58 teams from 30 hospitals participated (8 pediatric EDs [PEDs], 22 general EDs [GEDs]). The mean CQS was 71 (95% CI, 68-75); PEDs had a higher mean CQS (82; 95% CI, 79-85) vs GEDs (66; 95% CI, 63-69) and outperformed GEDs in all domains. However, when using generalized estimating equations to estimate CQS controlling for clustering of the data, PED status did not explain a higher CQS (beta = 4.28; 95% CI, -4.58 to 13.13) while the log of pediatric patient volume did explain a higher CQS (beta = 9.57; 95% CI, 2.64-16.49). The correlation of CQS to PRS was moderate (r = 0.51; P \u3c .001). The correlation was weak for cardiac arrest (r = 0.24; P = .07), weak for sepsis (rho = 0.45; P \u3c .001) and seizure (rho = 0.43; P = .001), and strong for teamwork (rho = 0.71; P \u3c .001). Conclusions and Relevance: This multicenter study noted significant differences in the quality of simulated pediatric resuscitative care across a spectrum of EDs. The CQS was higher in PEDs compared with GEDs. However, when controlling for pediatric patient volume and other variables in a multivariable model, PED status does not explain a higher CQS while pediatric patient volume does. The correlation of the PRS was moderate for simulation-based measures of quality

    International evidence-based guidelines on Point of Care Ultrasound (POCUS) for critically ill neonates and children issued by the POCUS Working Group of the European Society of Paediatric and Neonatal Intensive Care (ESPNIC).

    Get PDF
    BACKGROUND: Point-of-care ultrasound (POCUS) is nowadays an essential tool in critical care. Its role seems more important in neonates and children where other monitoring techniques may be unavailable. POCUS Working Group of the European Society of Paediatric and Neonatal Intensive Care (ESPNIC) aimed to provide evidence-based clinical guidelines for the use of POCUS in critically ill neonates and children. METHODS: Creation of an international Euro-American panel of paediatric and neonatal intensivists expert in POCUS and systematic review of relevant literature. A literature search was performed, and the level of evidence was assessed according to a GRADE method. Recommendations were developed through discussions managed following a Quaker-based consensus technique and evaluating appropriateness using a modified blind RAND/UCLA voting method. AGREE statement was followed to prepare this document. RESULTS: Panellists agreed on 39 out of 41 recommendations for the use of cardiac, lung, vascular, cerebral and abdominal POCUS in critically ill neonates and children. Recommendations were mostly (28 out of 39) based on moderate quality of evidence (B and C). CONCLUSIONS: Evidence-based guidelines for the use of POCUS in critically ill neonates and children are now available. They will be useful to optimise the use of POCUS, training programs and further research, which are urgently needed given the weak quality of evidence available

    Effect of mattress deflection on CPR quality assessment for older children and adolescents

    Get PDF
    Appropriate chest compression (CC) depth is associated with improved CPR outcome. CCs provided in hospital are often conducted on a compliant mattress. The objective was to quantify the effect of mattress compression on the assessment of CPR quality in children. Methods: A force and deflection sensor (FDS) was used during CPR in the Pediatric Intensive Care Unit and Emergency Department of a children's hospital. The sensor was interposed between the chest of the patient and hands of the rescuer and measured CC depth. Following CPR event, each event was reconstructed with a manikin and an identical mattress/backboard/patient configuration. CCs were performed using FDS on the sternum and a reference accelerometer attached to the spine of the manikin, providing a means to Calculate the mattress deflection. Results: Twelve CPR events with 14,487 CC (11 patients, median age 14.9 years) were recorded and reconstructed: 9 on ICU beds (9296 CC), 3 on stretchers (5191 CC). Measured mean CC depth during CPR was 47 +/- 8 mm on ICU beds, and 45 +/- 7 mm on stretcher beds with overestimation of 13 +/- 4 mm and 4 +/- 1 mm, respectively, due to mattress compression. After adjusting for this, the proportion of CC that met the CPR guidelines decreased from 88.4 to 31.8% on ICU beds (p < 0.001), and 86.3 to 64.7% on stretcher (p < 0.001 The proportion of appropriate depth CC was significantly smaller on ICU beds (p < 0.001). Conclusion: CC conducted on a non-rigid surface may not be deep enough. FDS may overestimate CC depth by 28% on ICU beds, and 10% on stretcher beds
    corecore