70 research outputs found

    Technical Considerations of Phosphorous-32 Bremsstrahlung SPECT Imaging after Radioembolization of Hepatic Tumors: A Clinical Assessment with a Review of Imaging Parameters

    Get PDF
    Background. Bremsstrahlung (BS) imaging during radioembolization (RE) confirms the deposition of radiotracer in hepatic/ extrahepatic tumors. The aimof this study is to demonstrate 32P images and to optimize the imaging parameters. Materials and Methods. Thirty-nine patientswith variable types of hepatic tumors, treatedwith the intra-arterial injection of 32P,were included. All patients underwent BS SPECT imaging 24–72 h after tracer administration, using lowenergy high resolution (LEHR) (18 patients) or medium energy general purpose (MEGP) (21 patients) collimators. A grading scale from1 to 4 was used to express the compatibility of the 32P images with those obtained from CT/MRI. Results. Although the image quality obtained with theMEGP collimator was visually and quantitatively better thanwith theLEHR(76%concordance score versus 71%, resp.), there was no statistically significant difference between them. Conclusion.The MEGP collimator is the first choice for BS SPECT imaging. However, if the collimator change is time consuming (as in a busy center) or an MEGP collimator is not available, the LEHR collimator could be practical with acceptable images, especially in a SPECT study. In addition, BS imaging is a useful method to confirm the proper distribution of radiotherapeutic agents and has good correlation with anatomical findings

    Magnetic resonance imaging in the evaluation of iron overload: A comparison of MRI, echocardiography and serum ferritin level in patients with β-thalassemia major

    Get PDF
    Purpose: This study aimed to evaluate iron levels in cardiac and hepatic tissues using magnetic resonance imaging (MRI) T2*. Methods: Cardiac and hepatic MRI was performed for 93 patients with β-thalassemia major. Results: Cardiac T2* was in the range of 2.9-56.6 ms. Myocardial siderosis was detected in 44 of patients; 25 patients had moderate and severe siderosis with serum ferritin level (SFL) of 576-10,284 ng/ml. There was a significant correlation between SFL and cardiac T2* (p<.001). Conclusions: The effective role of MRI as a noninvasive producible method in measurement of iron concentration in tissues is not accessible with conventional techniques. © 2012 Elsevier Inc

    Association of iron overload based quantitative T2* MRI technique and carotid intima-media thickness in patients with beta-thalassemia: A cross-sectional study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Body iron status has been implicated in atherosclerotic cardiovascular disease. The main hypothesis is that high iron status is associated with increased risk of atherosclerosis. We investigated the potential role of iron as an additional risk factor promoting atherosclerosis among beta-thalassemic patients.</p> <p>Methods</p> <p>In this cross-sectional study, the liver iron load was assessed by quantitative T2* MRI technique and intima-media thickness (IMT) of the common carotid artery by high-resolution ultrasound among 119 patients (62 male, 57 female) with beta-thalassemia (major and intermediate) whose age ranged from 10 to 50 years with a mean of 25.6 years. The patients were divided into three groups according to the severity of iron loading, obtained by T2*MRI technique: group I (normal), group II (mild) and group III (moderate and severe) iron load.</p> <p>For elimination of the effect of age on carotid IMT values, the patients also were divided into four age groups (10-19 y, 20-29 y, 30-39 y and 40-50 y). Mean carotid IMT based on the severity of iron loading were compared at different age groups, using one way ANOVA analysis for assessing the effect of iron loading on carotid IMT. Pearson's coefficient of correlation were used to assess the degree of correlation between studied variables (liver T2*, IMT, age).</p> <p>Results</p> <p>There were significant differences in mean carotid IMT based on the severity of iron loading at different age groups, with P = 0.003 at 20-29 y, P = 0.006 at 30-39 y and p = 0.037 at 40-50 y. Age (p = 0.001) and liver T2*(p = 0.003) had significant correlation with mean carotid IMT independently.</p> <p>At the age group of 10-19 years, there were not significant differences in mean carotid IMT based on the liver iron loading (p = 0.661).</p> <p>No significant differences also are seen in mean carotid IMT between male and female (p = 0.41).</p> <p>Conclusions</p> <p>This study identified a relationship between body iron status and carotid IMT. This relationship support to the hypothesis of a link between body iron load and atherosclerosis.</p

    Diagnostic Performance of 64-Channel Multislice Computed Tomography in Assessment of Significant Coronary Artery Disease in Symptomatic Subjects

    Get PDF
    The recent development of 64-channel multislice computed tomography (MSCT) has resulted in noninvasive coronary artery imaging improvement. This study was conducted to determine the accuracy of 64-slice MSCT in a relatively unselected group of 143 patients with presentations suggestive of coronary artery disease, including those with unstable angina pectoris, who underwent both coronary computed tomographic angiography and invasive coronary angiography. No arrhythmia was considered an exclusion criterion except for atrial fibrillation or frequent extrasystoles. In patients with fast heart rates, a β blocker was administered orally. Data were obtained using electrocardiography gated 64-slice MSCT. Computed tomographic angiography and invasive coronary angiography findings of each coronary segment were compared to determine the sensitivity, specificity, positive predictive value, and negative predictive value of MSCT in the detection of their normalcy or insignificant (<50 diameter decrease) stenosis versus significant (�50 diameter decrease) stenosis or total occlusion. In per-patient assessment, the calculated sensitivity, specificity, positive predictive value, and negative predictive value of MSCT were 96, 67, 91, and 83, respectively. These values in per-artery evaluation were 94, 94, 87, and 97, and corresponding values in per-segment analysis were 92, 97, 77, and 99, respectively. In conclusion, computed tomographic angiography has high diagnostic performance in the assessment of significant coronary artery disease in most patients in a daily routine practice, including those presenting with unstable angina pectoris symptoms. © 2007 Elsevier Inc. All rights reserved

    Fibrin sealants in lumbar annuloplasty after endoscopic discectomy as a method to prevent recurrent lumbar disc herniation.

    Get PDF
    Fibrin sealant as a promising agent for providing scaffold and efficient hemostasis is widely accepted in several specialties. However, the outcome of Fibrin sealants in lumbar annuloplasty after endoscopic discectomy has not been evaluated in patients with disc herniation. The goal of this study was to evaluate the efficacy, response, and probability of future recurrence rates in herniated nucleus pulposus (HNP) with the use of fibrin sealant in conjunction with endoscopic disc surgery. A total of 35 patients (28 men, 7women) were evaluated, including 18 patients who underwent endoscopic discectomy alone and 17 patients that received fibrin sealant at the site of annulus tear and endoscopic discectomy. All patients were followed through both clinical and imaging methods for an average of 10.5 months. Primary outcome measure was defined as lumbar decompression approved by imaging and symptom alleviation after endoscopic spinal discectomy with Visual Analogue Scale (VAS) score ≤ 4 (cut-off point). Median size of annular tearing was significantly lower in the endoscopic discectomy group (median, 3) (minimum, 2; maximum, 5); however, the corresponding factor in the endoscopic discectomy plus fibrin sealant group was significantly larger (median, 6) (minimum, 5; maximum, 10), with P <0.001. Only one patient in the endoscopic discectomy group had an HNP recurrence during follow-up compared to two patients in the endoscopic discectomy plus fibrin sealant group. Due to the temporary effects of fibrin sealant in preventing disc herniation and the observed recurrence rate in both the case and control groups, the results of this study suggest a role of fibrin sealants combined with endoscopic discectomy to prevent early HNP recurrence rate
    corecore