8 research outputs found

    EM simulation of a low-pass filter based on a microstrip defected ground structure using COMSOL

    Get PDF
    We perform EM simulations of a lowpass microstrip filter consisting of a crossjunction open stub and two unit sections implemented as defected ground structures (DGS). The defect introduced by unit sections corresponds to an etched lattice on the copper backside ground plane. The filter presents wide and deep attenuation characteristics in the stopband. Different model implementations were carried out with the aim at evaluating the computational costs versus accuracy. Simulations of a high-fidelity model are in good agreement with experimental data reported in a previous paper. COMSOL simulation settings, enclosing box, computational costs, and simulation times for the considered models are provided.ITESO, A.C.Intel Guadalajara Design Cente

    Transversal filter MMIC design for multi-Gbit/s optical CDMA systems

    Get PDF
    EThOS - Electronic Theses Online ServiceGBUnited Kingdo

    Surrogate modeling of microwave circuits using polynomial functional interpolants

    No full text
    A new formulation for developing surrogate models using polynomial-based functional interpolants is proposed in this work. Our formulation starts from a zero-order model that can be as simple as a fixed fine model response (for cases where a continuous coarse model is not available), or it can also be a simple linear input mapped coarse model. This zero-order model is enhanced by multidimensional polynomial interpolants around a central base point in the design space. The polynomial approximation is a low-order function of the design variables, and it is used to interpolate highly accurate electromagnetic responses in a region of interest around the selected central base point. Global optimal values for the surrogate model weighting factors are efficiently obtained in closed form, using compact formulas. Our technique is illustrated by a substrate integrated waveguide interconnect with CPW transitions.ITESO, A.C.Consejo Nacional de Ciencia y Tecnologí

    EM simulation of a low-pass filter based on a microstrip defected ground structure

    No full text
    We perform EM simulations of a lowpass microstrip filter consisting of a crossjunction open stub and two unit sections implemented as defected ground structures (DGS). The defect introduced by unit sections corresponds to an etched lattice on the copper backside ground plane. The filter presents wide and deep attenuation characteristics in the stopband. Different model implementations were carried out with the aim at evaluating the computational costs versus accuracy. Simulations of a high-fidelity model are in good agreement with experimental data reported in a previous paper. COMSOL simulation settings, enclosing box, computational costs, and simulation times for the considered models are provided

    EM simulation of a low-pass filter based on a microstrip defected ground structure

    No full text
    We perform EM simulations of a lowpass microstrip filter consisting of a crossjunction open stub and two unit sections implemented as defected ground structures (DGS). The defect introduced by unit sections corresponds to an etched lattice on the copper backside ground plane. The filter presents wide and deep attenuation characteristics in the stopband. Different model implementations were carried out with the aim at evaluating the computational costs versus accuracy. Simulations of a high-fidelity model are in good agreement with experimental data reported in a previous paper. COMSOL simulation settings, enclosing box, computational costs, and simulation times for the considered models are provided.ITESO, A.C

    Mexican Asthma Guidelines: GUIMA 2017

    No full text
    Background: The need for a national guideline, with a broad basis among specialists and primary care physicians was felt in Mexico, to try unifying asthma management. As several high-quality asthma guidelines exist worldwide, it was decided to select the best three for transculturation. Methods: Following the internationally recommended methodology for guideline transculturation, ADAPTE, a literature search for asthma guidelines, published 1-1-2007 through 31-12-2015 was conducted. AGREE-II evaluations yielded 3/40 most suitable for transculturation. Their compound evidence was fused with local reality, patient preference, cost and safety considerations to draft the guideline document. Subsequently, this was adjusted by physicians from 12 national medical societies in several rounds of a Delphi process and 3 face-to-face meetings to reach the final version. Results: Evidence was fused from British Thoracic Society Asthma Guideline 2014, Global Initiative on Asthma 2015, and Guía Española del Manejo del Asma 2015 (2016 updates included). After 3 Delphi-rounds we developed an evidence-based document taking into account patient characteristics, including age, treatment costs and safety and best locally available medication. Conclusion: In cooperation pulmonologists, allergists, ENT physicians, paediatricians and GPs were able to develop an evidence-based document for the prevention, diagnosis and treatment of asthma and its exacerbations in Mexico
    corecore