4 research outputs found

    The role of clinically relevant intra-abdominal collections after pancreaticoduodenectomy

    Get PDF
    Pancreatectomy complications; Pancreatic fistula; Postoperative collectionsComplicaciones de pancreatectomía; Fístula pancreática; Colecciones postoperatoriasComplicacions de pancreatectomia; Fístula pancreàtica; Col·leccions postoperatòriesBackground There is controversial evidence regarding the impact of clinically relevant postoperative intra-abdominal collections (CR-IC) on the clinical course after pancreaticoduodenectomy. C-reactive Protein (CRP) has been validated as a predictor of postoperative pancreatic fistula (POPF). Still, its role in predicting CR-IC has not been studied. Methods A retrospective analysis was conducted on patients who underwent PD at a tertiary hospital between October 2012 and October 2017. The incidence of CR-IC, clinically relevant POPF and other complications, as well as mortality and length of hospitalisation, was retrieved. The impact of CR-IR on mortality and major complications was analysed. The serum CRP levels were retrieved on the third and fifth postoperative days (POD3 and POD5), followed by an analysis of sensitivity, specificity, and area under the curve to predict CR-IC using CRP. Results One hundred forty patients were enrolled following inclusion and exclusion criteria. The mean age was 66.5 years (15–83). The incidence of CR-IC was 33.7% (47), and CR-POPF was 24.3%. Pancreatic duct diameter ≤ 4 mm was identified as a risk factor related to CR-IC occurrence. The group of patients who developed CR-IC after PD exhibited a higher rate of complications Clavien-Dindo ≥ III compared to patients without CR-IC (40.4% vs 7.5%, p  III: OR = 10.6 (95% CI: 3.90–28.7). No differences in mortality were reported between the CR-IC group and non-CR-IC group. CRP at postoperative day 3 (POD3) > 17.55 mg/dl and CRP at postoperative day 5 (POD5) > 13.46 mg/dl were predictors of CR-IC (AUC: 0.731 and AUC:0.821, respectively). Conclusions CR-IC has a significant impact after pancreaticoduodenectomy and is associated with a higher incidence of Clavien-Dindo ≥ III complications. Additionally, CRP levels at POD3 and POD5 play a role in predicting CR-IC. Prospective studies are essential to explore strategies for mitigating the occurrence of CR-IC after PD.Open Access Funding provided by Universitat Autonoma de Barcelona

    Sacral Neuromodulation in Patients With Low Anterior Resection Syndrome: The SANLARS Randomized Clinical Trial

    Full text link
    BACKGROUND: Sacral neuromodulation might be effective to palliate low anterior resection syndrome after rectal cancer surgery, but robust evidence is not available. OBJECTIVE: To assess the impact of sacral neuromodulation on low anterior resection syndrome symptoms as measured by validated scores and bowel diaries. DESIGN: Randomized, double-blind, 2-phased, controlled, multicenter crossover trial (NCT02517853). SETTINGS: Three tertiary hospitals. PATIENTS: Patients with major low anterior resection syndrome 12 months after transit reconstruction after rectal resection who had failed conservative treatment. INTERVENTIONS: Patients underwent an advanced test phase by stimulation for 3 weeks and received the pulse generator implant if a 50% reduction in low anterior resection syndrome score was achieved. These patients entered the randomized phase in which the generator was left active or inactive for 4 weeks. After a 2-week washout, the sequence was changed. After the crossover, all generators were left activated. MAIN OUTCOME MEASURES: The primary outcome was low anterior resection syndrome score reduction. Secondary outcomes included continence and bowel symptoms. RESULTS: After testing, 35 of 46 patients (78%) had a 50% or greater reduction in low anterior resection syndrome score. During the crossover phase, all patients showed a reduction in scores and improved symptoms, with better performance if the generator was active. At 6- and 12-month follow-up, the mean reduction in low anterior resection syndrome score was -6.2 (95% CI -8.97 to -3.43; p < 0.001) and -6.97 (95% CI -9.74 to -4.2; p < 0.001), with St. Mark's continence score -7.57 (95% CI -9.19 to -5.95, p < 0.001) and -8.29 (95% CI -9.91 to -6.66; p < 0.001). Urgency, bowel emptiness sensation, and clustering episodes decreased in association with quality-of-life improvement at 6- and 12-month follow-up. LIMITATIONS: The decrease in low anterior resection syndrome score with neuromodulation was underestimated because of an unspecific measuring instrument. There was a possible carryover effect in sham stimulation sequence. CONCLUSIONS: Neuromodulation provides symptoms and quality-of-life amelioration, supporting its use in low anterior resection syndrome. See Video Abstract

    Parastomal hernia prevention with permanent mesh in end colostomy : failure with late follow-up of cohorts in three randomized trials

    Get PDF
    Purpose: Short-term results have been reported regarding parastomal hernia (PH) prevention with a permanent mesh. Long-term results are scarce. The objective was to assess the long-term PH occurrence after a prophylactic synthetic non-absorbable mesh. Methods: Long-term data of three randomized controlled trials (RCTs) were collected. The primary outcome was the detection of PH based exclusively on a radiological diagnosis by computed tomography (CT) performed during the long-term follow-up. The Kaplan-Meier method was used for the comparison of time to diagnosis of PH according to the presence of mesh vs. no-mesh and the technique of mesh insertion: open retromuscular, laparoscopic keyhole, and laparoscopic modified Sugarbaker. Results: We studied 121 patients (87 men, median age 70 years), 82 (67.8%) of which developed a PH. The median overall length of follow-up was 48.5 months [interquartile range (IQR) 14.4-104.9], with a median time until PH diagnosis of 17.7 months (IQR 9.3-49.0). The survival analysis did not show significant differences in the time to development of a PH according to the presence or absence of a prophylactic mesh neither in the overall study population (log-rank, P = 0.094) nor in the groups of each technique of mesh insertion, although according to the surgical technique, a higher reduction in the appearance of PH for the open retromuscular technique was found (log-rank, P = 0.001). Conclusion: In the long-term follow-up placement of a non-absorbable synthetic prophylactic mesh in the context of an elective end colostomy does not seem effective for preventing PH

    Parastomal hernia prevention with permanent mesh in end colostomy : failure with late follow-up of cohorts in three randomized trials

    Get PDF
    Altres ajuts: acords transformatius de la UABShort-term results have been reported regarding parastomal hernia (PH) prevention with a permanent mesh. Long-term results are scarce. The objective was to assess the long-term PH occurrence after a prophylactic synthetic non-absorbable mesh. Long-term data of three randomized controlled trials (RCTs) were collected. The primary outcome was the detection of PH based exclusively on a radiological diagnosis by computed tomography (CT) performed during the long-term follow-up. The Kaplan-Meier method was used for the comparison of time to diagnosis of PH according to the presence of mesh vs. no-mesh and the technique of mesh insertion: open retromuscular, laparoscopic keyhole, and laparoscopic modified Sugarbaker. We studied 121 patients (87 men, median age 70 years), 82 (67.8%) of which developed a PH. The median overall length of follow-up was 48.5 months [interquartile range (IQR) 14.4-104.9], with a median time until PH diagnosis of 17.7 months (IQR 9.3-49.0). The survival analysis did not show significant differences in the time to development of a PH according to the presence or absence of a prophylactic mesh neither in the overall study population (log-rank, P = 0.094) nor in the groups of each technique of mesh insertion, although according to the surgical technique, a higher reduction in the appearance of PH for the open retromuscular technique was found (log-rank, P = 0.001). In the long-term follow-up placement of a non-absorbable synthetic prophylactic mesh in the context of an elective end colostomy does not seem effective for preventing PH
    corecore