340 research outputs found

    Evaluation of Four-Year Coronary Artery Response After Sirolimus-Eluting Stent Implantation Using Serial Quantitative Intravascular Ultrasound and Computer-Assisted Grayscale Value Analysis for Plaque Composition in Event-Free Patients

    Get PDF
    ObjectivesThis study sought to evaluate the long-term arterial response after sirolimus-eluting stent implantation.BackgroundSirolimus-eluting stents are effective in inhibiting neointimal hyperplasia without affecting plaque volume behind the stent struts at six months.MethodsSerial quantitative intravascular ultrasound and computer-assisted grayscale value analysis over four years were performed in 23 event-free patients treated with sirolimus-eluting stents.ResultsIn the first two years, the mean plaque volume (155.5 ± 42.8 mm3post-procedure and 156.8 ± 57.7 mm3at two years, p = 0.86) and plaque compositional change expressed as mean percent hypoechogenic tissue of the plaque behind the stent struts (78.9 ± 8.6% post-procedure and 78.2 ± 8.9% at two years, p = 0.67) did not significantly change. However, significant plaque shrinking (change in plaque volume = −18.4 mm3, p = 0.02) with an increase in plaque echogenicity (change in percent hypoechogenic tissue = −7.8%, p < 0.0001) was observed between two and four years. The mean neointimal volume increased over four years from 0 to 8.4 ± 5.8 mm3(p < 0.0001). However, no further statistically significant change occurred between two and four years (7.0 ± 6.7 mm3vs. 8.4 ± 5.8 mm3, p = 0.25).ConclusionsBetween two and four years after sirolimus-eluting stent implantation, peri-stent tissue shrank with a concomitant increase in echogenicity. These intravascular ultrasound findings suggest that late chronic artery responses may evolve for up to four years after sirolimus-eluting stent implantation. In addition, the fact that the neointima does not significantly change from two to four years may suggest that the biological phenomenon of a delayed healing response has begun to subside

    Predictors of long-term adverse events after Absorb bioresorbable vascular scaffold implantation: a 1,933-patient pooled analysis from international registries

    Get PDF
    Aims: The aim of this study was to investigate the predictors of long-term adverse clinical events after implantation of the everolimus-eluting Absorb bioresorbable vascular scaffold (BVS). Methods and results: We pooled patient-level databases derived from the large-scale ABSORB EXTEND study and five high-volume international centres. Between November 2011 and November 2015, 1,933 patients underwent PCI with a total of 2,372 Absorb BVS implanted. The median age was 61.0 (IQR 53.0 to 68.6) years, 24% had diabetes, and 68.2% presented with stable coronary artery disease. At a median follow-up of 616 days, MACE occurred in 93 (4.9%) patients, all-cause death in 36 (1.9%) patients, myocardial infarction in 47 (2.5%) patients, and target vessel revascularisation in 72 (3.8%) patients. Definite or probable scaffold thrombosis occurred in 26 (1.3%) patients. On multivariable logistic regression analysis, acute coronary syndromes (hazard ratio [HR] 2.79, 95% confidence interval [CI]: 1.47 to 5.29; p=0.002), dyslipidaemia (HR 1.43, 95% CI: 1.23 to 1.79; p=0.007), scaffold/reference diameter ratio &gt;1.25 (HR 1.49, 95% CI: 1.18 to 1.88; p=0.001), and residual stenosis &gt;15% (HR 1.67, 95% CI: 1.34 to 2.07; p&lt;0.001) were independent predictors of MACE, whereas the use of intravascular imaging was independently associated with a reduction in MACE (HR 0.13, 95% CI: 0.06 to 0.28; p&lt;0.001). Conclusions: Optimal Absorb BVS implantation and the use of intravascular imaging guidance are associated with lower rates of adverse events at long-term follow-up

    Sustained safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary lesions: 12-month clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial.

    Get PDF
    Metal absorbable scaffolds constitute a conceptually attractive alternative to polymeric scaffolds. Promising 6-month outcomes of a second-generation drug-eluting absorbable metal scaffold (DREAMS 2G), consisting of an absorbable magnesium scaffold backbone, have been reported. We assessed the 12-month safety and performance of this novel device. The prospective, international, multi-centre, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to two de novo lesions with a reference diameter between 2.2 and 3.7 mm. All patients were scheduled for angiographic follow-up at 6 months, and-if subjects consented-at 12 months. Dual antiplatelet therapy was recommended for 6 months. Quantitative coronary angiography (QCA) parameters remained stable from 6 to 12 months [paired data of 42 patients: in-segment late lumen loss 0.20 ± 0.21 mm vs. 0.25 ± 0.22 mm, P = 0.117, Δ 0.05 ± 0.21 mm (95% CI: -0.01;0.12); in-scaffold late lumen loss 0.37 ± 0.25 mm vs. 0.39 ± 0.27 mm, P = 0.446, Δ 0.03 ± 0.22 (95% CI: -0.04;0.10), respectively]. Intravascular ultrasound and optical coherence tomography findings corroborated the QCA results. Target lesion failure occurred in four patients (3.4%), consisting of one death of unknown cause, one target-vessel myocardial infarction, and two clinically driven target lesion revascularization. No additional event occurred beyond the 6-month follow-up. During the entire follow-up of 12 months, none of the patients experienced a definite or probable scaffold thrombosis. The novel drug-eluting metal absorbable scaffold DREAMS 2G showed a continuous favourable safety profile up to 12 months and stable angiographic parameters between 6 and 12 months. NCT01960504

    Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon- expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial

    Get PDF
    BACKGROUND: The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent. METHODS AND RESULTS: In the RAVEL trial, 238 patients with single de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx VELOCITY stent). In a subset of 95 patients (sirolimus-eluting stent=48, uncoated stent=47), motorized intravascular ultrasound pullback (0.5 mm/s) was performed at a 6-month follow-up. Stent volumes, total vessel volumes, and plaque-behind-stent volumes were comparable. However, the difference in neointimal hyperplasia (2+/-5 versus 37+/-28 mm3) and percent of volume obstruction (1+/-3% versus 29+/-20%) at 6 months between the 2 groups was highly significant (P<0.001), emphasizing the nearly complete abolition of the proliferative process inside the drug-eluting stent. Analysis of the proximal and distal edge volumes showed no significant difference between the 2 groups in external elastic membrane or lumen and plaque volume at the proximal and distal edges. There was also no evidence of intrastent thrombosis or persisting dissection at the stent edges. Although there was a higher incidence of incomplete stent apposition

    Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50%) of the left main coronary artery (LM). The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE) peak diastolic flow velocity (PDV) and intravascular ultrasound (IVUS) measurements in the assessment of angiographically borderline LM lesions.</p> <p>Methods</p> <p>27 patients (mean age 64 ± 8 years, 21 males) with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA) and plaque burden (PB) measurement and routine quantitative coronary angiography (QCA) with diameter stenosis (%DS) and area stenosis (%AS) assessment in all. During TTDE, resting PDV was measured in the LM.</p> <p>Results</p> <p>interpretable Doppler signal could be obtained in 24 patients (88% feasibility); therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm<sup>2</sup>. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p < 0.05) and plaque burden (r = 0.51, p < 0.05). Using a velocity cut-off of 112 cm/sec TTDE showed a 92% sensitivity and 62% specificity to identify IVUS-significant (MLA < 6 mm<sup>2</sup>) LM stenosis.</p> <p>Conclusion</p> <p>In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.</p
    corecore