318 research outputs found
Diffuse Gamma Rays: Galactic and Extragalactic Diffuse Emission
"Diffuse" gamma rays consist of several components: truly diffuse emission
from the interstellar medium, the extragalactic background, whose origin is not
firmly established yet, and the contribution from unresolved and faint Galactic
point sources. One approach to unravel these components is to study the diffuse
emission from the interstellar medium, which traces the interactions of high
energy particles with interstellar gas and radiation fields. Because of its
origin such emission is potentially able to reveal much about the sources and
propagation of cosmic rays. The extragalactic background, if reliably
determined, can be used in cosmological and blazar studies. Studying the
derived "average" spectrum of faint Galactic sources may be able to give a clue
to the nature of the emitting objects.Comment: 32 pages, 28 figures, kapproc.cls. Chapter to the book "Cosmic
Gamma-Ray Sources," to be published by Kluwer ASSL Series, Edited by K. S.
Cheng and G. E. Romero. More details can be found at
http://www.gamma.mpe-garching.mpg.de/~aws/aws.htm
Basket Cases and Breadbaskets: Sacred Rice and Agricultural Development in Postcolonial Africa
Author's final manuscript.Based on ethnographic research among rural Diola in Guinea-Bissau, I provide a broad view of the history and interpenetration of rice in social, political, religious, and ecological domains, while chronicling the current difficulties of residents in this region who are no longer able to grown enough of it. These farmers’ experiences are unfolding at a time of revitalized attention to agricultural development in Africa, particularly under the auspices of the New Green Revolution for Africa. I examine the premises that constitute the resuscitated effort to address the plight of African farmers. I argue that the totalizing quality of rice in Diola and other rice-cultivating societies requires a development approach that takes into account dimensions of agrarian life not encapsulated by the high- modernist and anti-political orientation of the New Green Revolution for Africa
Differential effects of pre and post-payment on neurologists' response rates to a postal survey
<p>Abstract</p> <p>Background</p> <p>Monetary incentives are an effective way of increasing response rates to surveys, though they are generally less effective in physicians, and are more effective when the incentive is paid up-front rather than when made conditional on completion.</p> <p>Methods</p> <p>In this study we examine the effectiveness of pre- and post-completion incentives on the response rates of all the neurologists in the UK to a survey about conversion disorder, using a cluster randomised controlled design. A postal survey was sent to all practicing consultant neurologists, in two rounds, including either a book token, the promise of a book token, or nothing at all.</p> <p>Results</p> <p>Three hundred and fifty-one of 591 eligible neurologists completed the survey, for a response rate of 59%. While the post-completion incentive exerted no discernible influence on response rates, a pre-completion incentive did, with an odds-ratio of 2.1 (95% confidence interval 1.5 - 3.0).</p> <p>Conclusions</p> <p>We conclude that neurologists, in the UK at least, may be influenced to respond to a postal survey by a pre-payment incentive but are unaffected by a promised reward.</p
Concurrent chemoradiotherapy with low dose weekly gemcitabine in stage III non-small cell lung cancer
BACKGROUND: Combined chemoradiotherapy (CRT) is the treatment of choice for stage III NSCLC. Gemcitabine (G) is a novel deoxycitidine analogue that has been proven to be a potent radiosensitizer. Twenty-two consecutive patients were treated with concurrent CRT to demonstrate the tolerability and efficacy of low dose G given weekly as radiosensitizer in stage III NSCLC. METHODS: Patients with KPS ≥70, adequate bone marrow reserve, with no prior radiotherapy (RT) and surgery were included. Eighteen patients had received prior induction chemotherapy (CT). G (75 mg/m(2)/week) was infused over 1 hour for 6 weeks. Thoracic RT was given two hours later over 6 weeks at 1.8 Gy/day fractions (total dose of 61.2 Gy). Pulmonary toxicity was evaluated with computed tomography scans in 6 weeks. RESULTS: Median age was 60 years (range, 48–75), median follow-up was 15 months (range, 2–40). Sixty-eight percent of patients were male and median KPS score was 90. Conformal 3D-RT planning was used in 64% of patients. G was given for a median of 5 weeks (range 1–9). Twelve patients (54.6%) received all planned CT. G was stopped because of intolerance in 6 and death in 2 patients. Seven patients (31.8%) had radiation pneumonitis. Twenty patients were evaluated for overall response, 1 patient (4.5%) had clinical CR, 81.8% had PR while 9.5% had SD. Median overall survival (OS) was 14 ± 5 months (95% CI 3–25). One- and 2-year OS rates were 55% and 38%. Sixteen patients died of disease-related events (6 with progression of primary tumor, 8 due to metastatic disease), 2 patients died of other causes. One- and 2-year progression-free survival and local control rates were 56%, 27% and 79%, 51%, respectively. CONCLUSION: G might be used as radiosensitizer for patients with stage III NSCLC who could not receive full doses CT with concurrent RT
Adjuvant gemcitabine and concurrent radiation for patients with resected pancreatic cancer: a phase II study
The safety and efficacy of gemcitabine and concurrent radiation to the upper abdomen followed by weekly gemcitabine in patients with resected pancreatic cancer was determined. Patients with resected adenocarcinoma of the pancreas were treated with intravenous gemcitabine administered twice-weekly (40 mg m−2) for 5 weeks concurrent with upper abdominal radiation (50.4 Gy in 5½ weeks). At the completion of the chemoradiation, patients without disease progression were given gemcitabine (1000 mg m−2) weekly for two cycles. Each cycle consisted of 3 weeks of treatment followed by 1 week without treatment. Forty-seven patients were entered, 46 of whom are included in this analysis. Characteristics: median age 61 years (range 35–79); 24 females (58%); 73% stage T3/T4; and 70% lymph node positive. Grade III/IV gastrointestinal or haematologic toxicities were infrequent. The median survival was 18.3 months, while the median time to disease recurrence was 10.3 months. Twenty-four percent of patients were alive at 3 years. Only six of 34 patients with progression experienced local regional relapse as a component of the first site of failure. These results confirm the feasibility of delivering adjuvant concurrent gemcitabine and radiation to the upper abdomen. This strategy produced good local regional tumour control
Effective Dark Matter Model: Relic density, CDMS II, Fermi LAT and LHC
The Cryogenic Dark Matter Search recently announced the observation of two
signal events with a 77% confidence level. Although statistically inconclusive,
it is nevertheless suggestive. In this work we present a model-independent
analysis on the implication of a positive signal in dark matter scattering off
nuclei. Assuming the interaction between (scalar, fermion or vector) dark
matter and the standard model induced by unknown new physics at the scale
, we examine various dimension-6 tree-level induced operators and
constrain them using the current experimental data, e.g. the WMAP data of the
relic abundance, CDMS II direct detection of the spin-independent scattering,
and indirect detection data (Fermi LAT cosmic gamma-ray), etc. Finally, the LHC
reach is also explored
Dalitz Plot Analysis of Ds to K+K-pi+
We perform a Dalitz plot analysis of the decay Ds to K+K-pi+ with the CLEO-c
data set of 586/pb of e+e- collisions accumulated at sqrt(s) = 4.17 GeV. This
corresponds to about 0.57 million D_s+D_s(*)- pairs from which we select 14400
candidates with a background of roughly 15%. In contrast to previous
measurements we find good agreement with our data only by including an
additional f_0(1370)pi+ contribution. We measure the magnitude, phase, and fit
fraction of K*(892) K+, phi(1020)pi+, K0*(1430)K+, f_0(980)pi+, f_0(1710)pi+,
and f_0(1370)pi+ contributions and limit the possible contributions of other KK
and Kpi resonances that could appear in this decay.Comment: 21 Pages,available through http://www.lns.cornell.edu/public/CLNS/,
submitted to PR
Search for D0 to p e- and D0 to pbar e+
Using data recorded by CLEO-c detector at CESR, we search for simultaneous
baryon and lepton number violating decays of the D^0 meson, specifically, D^0
--> p-bar e^+, D^0-bar --> p-bar e^+, D^0 --> p e^- and D^0-bar --> p e^-. We
set the following branching fraction upper limits: D^0 --> p-bar e^+ (D^0-bar
--> p-bar e^+) p e^- (D^0-bar --> p e^-) < 1.2 *
10^{-5}, both at 90% confidence level.Comment: 10 pages, available through http://www.lns.cornell.edu/public/CLNS/,
submitted to PRD. Comments: changed abstract, added reference for section 1,
vertical axis in Fig.5 changed (starts from 1.5 rather than 2.0), fixed typo
Precision Measurement of B(D+ -> mu+ nu) and the Pseudoscalar Decay Constant fD+
We measure the branching ratio of the purely leptonic decay of the D+ meson
with unprecedented precision as B(D+ -> mu+ nu) = (3.82 +/- 0.32 +/-
0.09)x10^(-4), using 818/pb of data taken on the psi(3770) resonance with the
CLEO-c detector at the CESR collider. We use this determination to derive a
value for the pseudoscalar decay constant fD+, combining with measurements of
the D+ lifetime and assuming |Vcd| = |Vus|. We find fD+ = (205.8 +/- 8.5 +/-
2.5) MeV. The decay rate asymmetry [B(D+ -> mu+ nu)-B(D- -> mu- nu)]/[B(D+ ->
mu+ nu)+B(D- -> mu- nu)] = 0.08 +/- 0.08, consistent with no CP violation. We
also set 90% confidence level upper limits on B(D+ -> tau+ nu) < 1.2x10^(-3)
and B(D+ -> e+ nu) < 8.8x10^(-6).Comment: 24 pages, 11 figures and 6 tables, v2 replaced some figure vertical
axis scales, v3 corrections from PRD revie
Precision Measurement of the Mass of the h_c(1P1) State of Charmonium
A precision measurement of the mass of the h_c(1P1) state of charmonium has
been made using a sample of 24.5 million psi(2S) events produced in e+e-
annihilation at CESR. The reaction used was psi(2S) -> pi0 h_c, pi0 -> gamma
gamma, h_c -> gamma eta_c, and the reaction products were detected in the
CLEO-c detector.
Data have been analyzed both for the inclusive reaction and for the exclusive
reactions in which eta_c decays are reconstructed in fifteen hadronic decay
channels. Consistent results are obtained in the two analyses. The averaged
results of the present measurements are M(h_c)=3525.28+-0.19 (stat)+-0.12(syst)
MeV, and B(psi(2S) -> pi0 h_c)xB(h_c -> gamma eta_c)= (4.19+-0.32+-0.45)x10^-4.
Using the 3PJ centroid mass, Delta M_hf(1P)= - M(h_c) =
+0.02+-0.19+-0.13 MeV.Comment: 9 pages, available through http://www.lns.cornell.edu/public/CLNS/,
submitted to PR
- …