350 research outputs found
A Tablet-based Virtual Environment for Neurosurgery Training
Published in Presence: Teleoperators and Virtual Environments, Spring 2015No. 2, Pages 155-162
Posted Online October 15, 2015. doi:10.1162/PRES_a_00224The requirement for training surgical procedures without exposing the patient to additional risk is well accepted and is part of a national drive in the UK and internationally. Computer-based simulations are important in this context, including neurosurgical resident training. The objective of this study is to evaluate the effectiveness of a custom built virtual environment in assisting training of a ventriculostomy procedure. The training tool (called VCath) has been developed as an app for a tablet platform to provide easy access and availability to trainees. The study was conducted at the first boot camp organized for all year one trainees in neurosurgery in the UK. The attendees were randomly distributed between the VCath training group and the Control group. Efficacy of performing ventriculostomy for both groups was assessed at the beginning and end of the study using a simulated insertion task. Statistically significant changes in performance of selecting the burr hole entry point, the trajectory length and duration metrics for the VCath group, together with a good indicator of improved normalized jerk (representing the speed and smoothness of arm motion), all suggest that there has been a higher level cognitive benefit to using VCath. The app is successful as it is focused on the cognitive task of ventriculostomy, encouraging the trainee to rehearse the entry point and use anatomical landmarks to create a trajectory to the target. In straight-line trajectory procedures such as ventriculostomy, cognitive task based education is a useful adjunct to traditional methods and may reduce the learning curve and ultimately improve patient safety
Resource use data by patient report or hospital records: Do they agree?
Background: Economic evaluations alongside clinical trials are becoming increasingly common.
Cost data are often collected through the use of postal questionnaires; however, the accuracy of
this method is uncertain. We compared postal questionnaires with hospital records for collecting
data on physiotherapy service use.
Methods: As part of a randomised trial of orthopaedic medicine compared with orthopaedic
surgery we collected physiotherapy use data on a group of patients from retrospective postal
questionnaires and from hospital records.
Results: 315 patients were referred for physiotherapy. Hospital data on attendances was available
for 30% (n = 96), compared with 48% (n = 150) of patients completing questionnaire data (95% Cl
for difference = 10% to 24%); 19% (n = 59) had data available from both sources. The two methods
produced an intraclass correlation coefficient of 0.54 (95% Cl 0.31 to 0.70). However, the two
methods produced significantly different estimates of resource use with patient self report recalling
a mean of 1.3 extra visits (95% Cl 0.4 to 2.2) compared with hospital records.
Conclusions: Using questionnaires in this study produced data on a greater number of patients
compared with examination of hospital records. However, the two data sources did differ in the
quantity of physiotherapy used and this should be taken into account in any analysi
R-process enrichment from a single event in an ancient dwarf galaxy
Elements heavier than zinc are synthesized through the (r)apid and (s)low
neutron-capture processes. The main site of production of the r-process
elements (such as europium) has been debated for nearly 60 years. Initial
studies of chemical abundance trends in old Milky Way halo stars suggested
continual r-process production, in sites like core-collapse supernovae. But
evidence from the local Universe favors r-process production mainly during rare
events, such as neutron star mergers. The appearance of a europium abundance
plateau in some dwarf spheroidal galaxies has been suggested as evidence for
rare r-process enrichment in the early Universe, but only under the assumption
of no gas accretion into the dwarf galaxies. Cosmologically motivated gas
accretion favors continual r-process enrichment in these systems. Furthermore,
the universal r-process pattern has not been cleanly identified in dwarf
spheroidals. The smaller, chemically simpler, and more ancient ultra-faint
dwarf galaxies assembled shortly after the first stars formed, and are ideal
systems with which to study nucleosynthesis events such as the r-process.
Reticulum II is one such galaxy. The abundances of non-neutron-capture elements
in this galaxy (and others like it) are similar to those of other old stars.
Here, we report that seven of nine stars in Reticulum II observed with
high-resolution spectroscopy show strong enhancements in heavy neutron-capture
elements, with abundances that follow the universal r-process pattern above
barium. The enhancement in this "r-process galaxy" is 2-3 orders of magnitude
higher than that detected in any other ultra-faint dwarf galaxy. This implies
that a single rare event produced the r-process material in Reticulum II. The
r-process yield and event rate are incompatible with ordinary core-collapse
supernovae, but consistent with other possible sites, such as neutron star
mergers.Comment: Published in Nature, 21 Mar 2016:
http://dx.doi.org/10.1038/nature1742
Silent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty: Early detection with routine metal artifact-reduction MRI scanning
Adverse reactions to metal debris have been reported to be a cause of pain in metal-on-metal hip arthroplasty. We assessed the incidence of both symptomatic and asymptomatic adverse reactions in a consecutive series of patients with a modern large-head metal-on-metal hip arthroplasty
Converting simulated total dry matter to fresh marketable yield for field vegetables at a range of nitrogen supply levels
Simultaneous analysis of economic and environmental performance of horticultural crop production requires qualified assumptions on the effect of management options, and particularly of nitrogen (N) fertilisation, on the net returns of the farm. Dynamic soil-plant-environment simulation models for agro-ecosystems are frequently applied to predict crop yield, generally as dry matter per area, and the environmental impact of production. Economic analysis requires conversion of yields to fresh marketable weight, which is not easy to calculate for vegetables, since different species have different properties and special market requirements. Furthermore, the marketable part of many vegetables is dependent on N availability during growth, which may lead to complete crop failure under sub-optimal N supply in tightly calculated N fertiliser regimes or low-input systems. In this paper we present two methods for converting simulated total dry matter to marketable fresh matter yield for various vegetables and European growth conditions, taking into consideration the effect of N supply: (i) a regression based function for vegetables sold as bulk or bunching ware and (ii) a population approach for piecewise sold row crops. For both methods, to be used in the context of a dynamic simulation model, parameter values were compiled from a literature survey. Implemented in such a model, both algorithms were tested against experimental field data, yielding an Index of Agreement of 0.80 for the regression strategy and 0.90 for the population strategy. Furthermore, the population strategy was capable of reflecting rather well the effect of crop spacing on yield and the effect of N supply on product grading
Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines
<p>Abstract</p> <p>Background</p> <p>Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System.</p> <p>Methods</p> <p>The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC) with 95% confidence intervals (CI) were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM) calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD) was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability.</p> <p>Results</p> <p>The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines.</p> <p>Conclusion</p> <p>The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high.</p
Gated myocardial perfusion SPECT underestimates left ventricular volumes and shows high variability compared to cardiac magnetic resonance imaging -- a comparison of four different commercial automated software packages
Abstract Background We sought to compare quantification of left ventricular volumes and ejection fraction by different gated myocardial perfusion SPECT (MPS) programs with each other and to magnetic resonance (MR) imaging. Methods N = 100 patients with known or suspected coronary artery disease were examined at rest with 99 mTc-tetrofosmin gated MPS and cardiac MR imaging. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were obtained by analysing gated MPS data with four different programs: Quantitative Gated SPECT (QGS), GE MyoMetrix, Emory Cardiac Toolbox (ECTb) and Exini heart. Results All programs showed a mean bias compared to MR imaging of approximately -30% for EDV (-22 to -34%, p Conclusions Gated MPS, systematically underestimates left ventricular volumes by approximately 30% and shows a high variability, especially for ESV. For EF, accuracy was better, with a mean bias between -15 and 6% of EF. It may be of value to take this into consideration when determining absolute values of LV volumes and EF in a clinical setting.</p
A rasch analysis of the Manchester foot pain and disability index
© 2009 Muller and Roddy; licensee BioMed Central Ltd
The Galactic Center Black Hole Laboratory
The super-massive 4 million solar mass black hole Sagittarius~A* (SgrA*)
shows flare emission from the millimeter to the X-ray domain. A detailed
analysis of the infrared light curves allows us to address the accretion
phenomenon in a statistical way. The analysis shows that the near-infrared
flare amplitudes are dominated by a single state power law, with the low states
in SgrA* limited by confusion through the unresolved stellar background. There
are several dusty objects in the immediate vicinity of SgrA*. The source G2/DSO
is one of them. Its nature is unclear. It may be comparable to similar stellar
dusty sources in the region or may consist predominantly of gas and dust. In
this case a particularly enhanced accretion activity onto SgrA* may be expected
in the near future. Here the interpretation of recent data and ongoing
observations are discussed.Comment: 30 pages - 7 figures - accepted for publication by Springer's
"Fundamental Theories of Physics" series; summarizing GC contributions of 2
conferences: 'Equations of Motion in Relativistic Gravity' at the
Physikzentrum Bad Honnef, Bad Honnef, Germany, (Feb. 17-23, 2013) and the
COST MP0905 'The Galactic Center Black Hole Laboratory' Granada, Spain (Nov.
19 - 22, 2013
- …