6,126 research outputs found

    Neutrino Telescopes as a Direct Probe of Supersymmetry Breaking

    Full text link
    We consider supersymmetric models where the scale of supersymmetry breaking lies between 5 ×106\times 10^6 GeV and 5 ×108\times 10^8 GeV. In this class of theories, which includes models of gauge mediated supersymmetry breaking, the lightest supersymmetric particle is the gravitino. The next to lightest supersymmetric particle is typically a long lived charged slepton with a lifetime between a microsecond and a second, depending on its mass. Collisions of high energy neutrinos with nucleons in the earth can result in the production of a pair of these sleptons. Their very high boost means they typically decay outside the earth. We investigate the production of these particles by the diffuse flux of high energy neutrinos, and the potential for their observation in large ice or water Cerenkov detectors. The relatively small cross-section for the production of supersymmetric particles is partially compensated for by the very long range of heavy particles. The signal in the detector consists of two parallel charged tracks emerging from the earth about 100 meters apart, with very little background. A detailed calculation using the Waxman-Bahcall limit on the neutrino flux and realistic spectra shows that km3^3 experiments could see as many as 4 events a year. We conclude that neutrino telescopes will complement collider searches in the determination of the supersymmetry breaking scale, and may even give the first evidence for supersymmetry at the weak scale.Comment: 4 pages, 3 figure

    A Novel Low-Cost Sensor Prototype for Nocturia Monitoring in Older People

    Get PDF
    Indexación: Scopus.This work was supported in part by CORFO - CENS 16CTTS-66390 through the National Center on Health Information Systems, in part by the National Commission for Scientific and Technological Research (CONICYT) through the program STIC-AMSUD 17STIC-03: ‘‘e-MONITOR âĂŞ Chronic Disease: Ambient Assisted Living and vital teleMONOTORing for e-health,’’ FONDEF ID16I10449 ‘‘Sistema inteligente para la gestión y análisis de la dotación de camas en la red asistencial del sector público,’’ and MEC80170097 ‘‘Red de colaboración científica entre universidades nacionales e internacionales para la estructuración del doctorado y magister en informática médica en la Universidad de Valparaíso.’’ The work of V. H. C. de Albuquerque was supported by the Brazilian National Council for Research and Development (CNPq) under Grant #304315/2017-6.Nocturia is frequently defined as the necessity to get out of bed at least one time during the night to urinate, with each of these episodes being preceded and continued by sleep. Several studies suggest that an increase of nocturia is seen with the onset of age, occurring in around 70% of adults over the age of 70. Its appearance is associated with detrimental quality of life for those who present nocturia, since it leads to daytime sleepiness, cognitive dysfunction, among others. Currently, a voiding diary is necessary for nocturia assessment; these are prone to bias due to their inherent subjectivity. In this paper, we present the design of a low-cost device that automatically detects micturition events. The device obtained 73% in sensibility and 81% in specificity; these results show that systems such as the proposed one can be a valuable tool for the medical team when evaluating nocturia. © 2013 IEEE.https://ieeexplore.ieee.org/document/845445

    A novel monitoring system for fall detection in older people

    Get PDF
    Indexación: Scopus.This work was supported in part by CORFO - CENS 16CTTS-66390 through the National Center on Health Information Systems, in part by the National Commission for Scientific and Technological Research (CONICYT) through the Program STIC-AMSUD 17STIC-03: ‘‘MONITORing for ehealth," FONDEF ID16I10449 ‘‘Sistema inteligente para la gestión y análisis de la dotación de camas en la red asistencial del sector público’’, and in part by MEC80170097 ‘‘Red de colaboración científica entre universidades nacionales e internacionales para la estructuración del doctorado y magister en informática médica en la Universidad de Valparaíso’’. The work of V. H. C. De Albuquerque was supported by the Brazilian National Council for Research and Development (CNPq), under Grant 304315/2017-6.Each year, more than 30% of people over 65 years-old suffer some fall. Unfortunately, this can generate physical and psychological damage, especially if they live alone and they are unable to get help. In this field, several studies have been performed aiming to alert potential falls of the older people by using different types of sensors and algorithms. In this paper, we present a novel non-invasive monitoring system for fall detection in older people who live alone. Our proposal is using very-low-resolution thermal sensors for classifying a fall and then alerting to the care staff. Also, we analyze the performance of three recurrent neural networks for fall detections: Long short-term memory (LSTM), gated recurrent unit, and Bi-LSTM. As many learning algorithms, we have performed a training phase using different test subjects. After several tests, we can observe that the Bi-LSTM approach overcome the others techniques reaching a 93% of accuracy in fall detection. We believe that the bidirectional way of the Bi-LSTM algorithm gives excellent results because the use of their data is influenced by prior and new information, which compares to LSTM and GRU. Information obtained using this system did not compromise the user's privacy, which constitutes an additional advantage of this alternative. © 2013 IEEE.https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=842305

    Mechanisms for Spin-Supersolidity in S=1/2 Spin-Dimer Antiferromagnets

    Full text link
    Using perturbative expansions and the contractor renormalization (CORE) algorithm, we obtain effective hard-core bosonic Hamiltonians describing the low-energy physics of S=1/2S=1/2 spin-dimer antiferromagnets known to display supersolid phases under an applied magnetic field. The resulting effective models are investigated by means of mean-field analysis and quantum Monte Carlo simulations. A "leapfrog mechanism", through means of which extra singlets delocalize in a checkerboard-solid environment via correlated hoppings, is unveiled that accounts for the supersolid behavior.Comment: 12 pages, 10 figure

    Monitorization of alveolar deposited surface area of nanoparticles and ultrafine particles in different environments

    Get PDF
    Nanotechnology is an important emerging industry with a projected annual market of around one trillion dollars by 2015. It involves the control of atoms and molecules to create new materials with a variety of useful functions. Although there are advantages on the utilization of these nano-scale materials, questions related with its impact over the environment and human health must be addressed too, so that potential risks can be limited at early stages of development. At this time, occupational health risks associated with manufacturing and use of nanoparticles are not yet clearly understood. However, workers may be exposed to nanoparticles through inhalation at levels that can greatly exceed ambient concentrations. Current workplace exposure limits are based on particle mass, but this criteria could not be adequate in this case as nanoparticles are characterized by very large surface area, which has been pointed out as the distinctive characteristic that could even turn out an inert substance into another substance exhibiting very different interactions with biological fluids and cells. Therefore, it seems that, when assessing human exposure based on the mass concentration of particles, which is widely adopted for particles over 1 μm, would not work in this particular case. In fact, nanoparticles have far more surface area for the equivalent mass of larger particles, which increases the chance they may react with body tissues. Thus, it has been claimed that surface area should be used for nanoparticle exposure and dosing. As a result, assessing exposure based on the measurement of particle surface area is of increasing interest. It is well known that lung deposition is the most efficient way for airborne particles to enter the body and cause adverse health effects. If nanoparticles can deposit in the lung and remain there, have an active surface chemistry and interact with the body, then, there is potential for exposure. It was showed that surface area plays an important role in the toxicity of nanoparticles and this is the metric that best correlates with particle-induced adverse health effects. The potential for adverse health effects seems to be directly proportional to particle surface area. The objective of the study is to identify and validate methods and tools for measuring nanoparticles during production, manipulation and use of nanomaterials

    X, Y and Z States

    Full text link
    Many new states in the charmonium mass region were recently discovered by BaBar, Belle, CLEO-c, CDF, D0, BESIII, LHCb and CMS Collaborations. We use the QCD Sum Rule approach to study the possible structure of some of these states.Comment: Contribution for the proceedings of the "XII Quark Confinement and the Hadron Spectrum - CONF12" conferenc

    Remote Gait type classification system using markerless 2D video

    Get PDF
    Several pathologies can alter the way people walk, i.e., their gait. Gait analysis can be used to detect such alterations and, therefore, help diagnose certain pathologies or assess people’s health and recovery. Simple vision-based systems have a considerable potential in this area, as they allow the capture of gait in unconstrained environments, such as at home or in a clinic, while the required computations can be done remotely. State-of-the-art vision-based systems for gait analysis use deep learning strategies, thus requiring a large amount of data for training. However, to the best of our knowledge, the largest publicly available pathological gait dataset contains only 10 subjects, simulating 5 types of gait. This paper presents a new dataset, GAIT-IT, captured from 21 subjects simulating 5 types of gait, at 2 severity levels. The dataset is recorded in a professional studio, making the sequences free of background camouflage, variations in illumination and other visual artifacts. The dataset is used to train a novel automatic gait analysis system. Compared to the state-of-the-art, the proposed system achieves a drastic reduction in the number of trainable parameters, memory requirements and execution times, while the classification accuracy is on par with the state-of-the-art. Recognizing the importance of remote healthcare, the proposed automatic gait analysis system is integrated with a prototype web application. This prototype is presently hosted in a private network, and after further tests and development it will allow people to upload a video of them walking and execute a web service that classifies their gait. The web application has a user-friendly interface usable by healthcare professionals or by laypersons. The application also makes an association between the identified type of gait and potential gait pathologies that exhibit the identified characteristics.info:eu-repo/semantics/publishedVersio
    • …
    corecore