7 research outputs found

    Detection of the peanut allergen Ara h 6 in foodstuffs using a voltammetric biosensing approach

    Get PDF
    A voltammetric biosensor for Ara h 6 (a peanut allergen) detection in food samples was developed. Gold nanoparticle-modified screen-printed carbon electrodes were used to develop a sandwich-type immunoassay using two-monoclonal antibodies. The antibody-antigen interaction was detected through the electrochemical detection of enzymatically deposited silver. The immunosensor presented a linear range between 1 and 100 ng/ml, as well as high precision (inter-day RSD ≀9.8 %) and accuracy (recoveries ≄96.7 %). The detection and quantification limits were 0.27 and 0.88 ng/ml, respectively. It was possible to detect small levels of Ara h 6 in complex food matrices

    Variable IgE cross-reactivity between peanut 2S-albumins: The case for measuring IgE to both Ara h 2 and Ara h 6.

    No full text
    BACKGROUND:2S-albumins Ara h 2 and Ara h 6 are the most potent peanut allergens and levels of specific immunoglobulin E (IgE) towards these proteins are good predictors of clinical reactivity. Because of structural homologies, Ara h 6 is generally considered to cross-react extensively with Ara h 2.OBJECTIVE:We aimed to quantify the IgE cross-reactivity between Ara h 2 and Ara h 6.METHODS:Peanut 2S-albumins were purified from raw peanuts. The IgE cross-reactivity between Ara h 2 and Ara h 6 was evaluated with 32 sera from French and US peanut-allergic patients by measuring the residual IgE-binding to one 2S-albumin after depletion of IgE antibodies recognizing the other 2S-albumin. The IgE cross-reactivity between Ara h 2 and Ara h 6 was further investigated by competitive inhibition of IgE-binding and by a model of mast cell degranulation.RESULTS:A highly variable level of IgE cross-reactivity was revealed among the patients. The mean fraction of cross-reactive IgE antibodies represented only 17.1% of 2S-albumins-specific IgE antibodies and was lower than the mean fraction of IgE specific to Ara h 2 (57.4%) or to Ara h 6 (25.5%). The higher level of Ara h 2-specific IgE was principally due to the IgE-binding capacity of an insertion containing the repeated immunodominant linear epitope DPYSPOH S. The impact of IgE cross-reactivity on diagnostic testing was illustrated with a serum displaying an Ara h 6-specific IgE response of 26 UI/mL that was not associated with the capacity of Ara h 6 to trigger mast cell degranulation.CONCLUSIONS & CLINICAL RELEVANCE:Immunoglobulin E antibodies specific to peanut 2S-albumins are mainly non-cross-reactive, but low-affinity cross-reactivity can affect diagnostic accuracy. Testing IgE-binding to a mixture of 2S-albumins rather than to each separately may enhance diagnostic performance
    corecore