    Evaluation of three instrumentation techniques at the precision of apical stop and apical sealing of obturation

    Get PDF
    OBJECTIVE: The aim of this study was to investigate the ability of two NiTi rotary apical preparation techniques used with an electronic apex locator-integrated endodontic motor and a manual technique to create an apical stop at a predetermined level (0.5 mm short of the apical foramen) in teeth with disrupted apical constriction, and to evaluate microleakage following obturation in such prepared teeth. MATERIAL AND METHODS: 85 intact human mandibular permanent incisors with single root canal were accessed and the apical constriction was disrupted using a #25 K-file. The teeth were embedded in alginate and instrumented to #40 using rotary Lightspeed or S-Apex techniques or stainless-steel K-files. Distance between the apical foramen and the created apical stop was measured to an accuracy of 0.01 mm. In another set of instrumented teeth, root canals were obturated using gutta-percha and sealer, and leakage was tested at 1 week and 3 months using a fluid filtration device. RESULTS: All techniques performed slightly short of the predetermined level. Closest preparation to the predetermined level was with the manual technique and the farthest was with S-Apex. A significant difference was found between the performances of these two techniques (

    Comparison of debris extruded apically and working time used by ProTaper Universal rotary and ProTaper retreatment system during gutta-percha removal

    Get PDF
    OBJECTIVE: The aim of this study was to evaluate the in vitro action of ProTaper retreatment files and ProTaper Universal in the retreatment of mandibular premolars. MATERIAL AND METHODS: The amount of debris extruded apically was measured and the time to reach the working length and to complete the removal of gutta-percha was observed. Thirty teeth had their canals prepared using ProTaper Universal files and were obturated by the single cone technique. The teeth were then stored at 37ºC in a humid environment for 7 days. During the use of the rotary instruments for root canal filling removal, the apical portions of the teeth were attached to the open end of a resin tube to collect the apically extruded debris. RESULTS: ProTaper Universal files were significantly faster (p=0.0011) than the ProTaper retreatment files to perform gutta-percha removal, but no significant difference was found between the files regarding the time to reach the working length or the amount of apical extrusion. CONCLUSIONS: ProTaper Universal rotary had better results for endodontic retreatment, and both techniques promote similar apical extrusion of debris

    Effect of Needle Insertion Depth and Apical Diameter on Irrigant Extrusion in Simulated Immature Permanent Teeth

    No full text
    The aim of this study was to compare the amount of irrigant extrusion in simulated immature permanent teeth when the apical diameter and needle insertion depth were varied. Thirty single-rooted maxillary incisors with straight root canals were selected. The root length was standardized to a length of 9 mm. The teeth were divided into two experimental groups according to the degree of apical enlargement (n = 15). The apices were enlarged to a diameter of 1.10 mm or 1.70 mm by using a #3 or #6 peeso reamer, respectively, to simulate immature teeth. The irrigation solution was applied 2 or 4 mm short of the working length (WL) in each experimental group. The glass vial model was used for the collection of extruded irrigant beyond the root apex. A two-way repeated measures analysis of variance test showed that there was no significant difference between different needle insertion depths (2 and 4 mm short of the WL) in the group with an apical diameter of 1.70 mm (p > 0.05). In the group with an apical diameter of 1.10 mm, a 32% increase in irrigant extrusion was observed when the needle was positioned at 2 mm (p < 0.05). Regarding the effect of apical diameter, the group with a diameter of 1.70 mm showed more apical extrusion of the irrigant (34% increase for the needle positioned at 2 mm and 68% increase for the needle positioned at 4 mm). It was observed that the needle insertion depth and apical diameter have a significant effect on irrigant extrusion in immature permanent teeth.Wo