358 research outputs found

    Regulations & exemptions during the COVID-19 pandemic for new medical technology, health services & data

    Get PDF
    The rapid evolution of the COVID-19 pandemic has sparked a large unmet need for new or additional medical technology and healthcare services to be made available urgently. Healthcare, Academic, Government and Industry organizations and individuals have risen to this challenge by designing, developing, manufacturing or implementing innovation. However, both they and healthcare stakeholders are hampered as it is unclear how to introduce and deploy the products of this innovation quickly and legally within the healthcare system. Our paper outlines the key regulations and processes innovators need to comply with, and how these change during a public health emergency via dedicated exemptions. Our work includes references to the formal documents regarding UK healthcare regulation and governance, and is meant to serve as a guide for those who wish to act quickly but are uncertain of the legal and regulatory pathways that allow new a device or service to be fast-tracked

    On effective actions of BPS branes and their higher derivative corrections

    Get PDF
    We calculate in detail the disk level S-matrix element of one Ramond-Ramond field and three gauge field vertex operators in the world volume of BPS branes, to find four gauge field couplings to all orders of α\alpha' up to on-shell ambiguity. Then using these infinite couplings we find that the massless pole of the field theory amplitude is exactly equal to the massless pole S-matrix element of this amplitude for the p=np=n case to all orders of α\alpha'. Finally we show that the infinite massless poles and the contact terms of this amplitude for the p=n+2p=n+2 case can be reproduced by the Born-Infeld action and the Wess-Zumino actions and by their higher derivative corrections.Comment: 26 pages, 2 figures, minor corrections,references added and version published in JHE

    Complete Nucleotide Sequence of CTX-M-15-Plasmids from Clinical Escherichia coli Isolates: Insertional Events of Transposons and Insertion Sequences

    Get PDF
    BACKGROUND: CTX-M-producing Escherichia coli strains are regarded as major global pathogens. METHODOLOGY/PRINCIPAL FINDINGS: The nucleotide sequence of three plasmids (pEC_B24: 73801-bp; pEC_L8: 118525-bp and pEC_L46: 144871-bp) from Escherichia coli isolates obtained from patients with urinary tract infections and one plasmid (pEC_Bactec: 92970-bp) from an Escherichia coli strain isolated from the joint of a horse with arthritis were determined. Plasmid pEC_Bactec belongs to the IncI1 group and carries two resistance genes: bla(TEM-1) and bla(CTX-M-15). It shares more than 90% homology with a previously published bla(CTX-M)-plasmid from E. coli of human origin. Plasmid pEC_B24 belongs to the IncFII group whereas plasmids pEC_L8 and pEC_L46 represent a fusion of two replicons of type FII and FIA. On the pEC_B24 backbone, two resistance genes, bla(TEM-1) and bla(CTX-M-15), were found. Six resistance genes, bla(TEM-1), bla(CTX-M-15), bla(OXA-1), aac6'-lb-cr, tetA and catB4, were detected on the pEC_L8 backbone. The same antimicrobial drug resistance genes, with the exception of tetA, were also identified on the pEC_L46 backbone. Genome analysis of all 4 plasmids studied provides evidence of a seemingly frequent transposition event of the bla(CTX-M-15)-ISEcp1 element. This element seems to have a preferred insertion site at the tnpA gene of a bla(TEM)-carrying Tn3-like transposon, the latter itself being inserted by a transposition event. The IS26-composite transposon, which contains the bla(OXA-1), aac6'-lb-cr and catB4 genes, was inserted into plasmids pEC_L8 and pEC_L46 by homologous recombination rather than a transposition event. Results obtained for pEC_L46 indicated that IS26 also plays an important role in structural rearrangements of the plasmid backbone and seems to facilitate the mobilisation of fragments from other plasmids. CONCLUSIONS: Collectively, these data suggests that IS26 together with ISEcp1 could play a critical role in the evolution of diverse multiresistant plasmids found in clinical Enterobacteriaceae

    Stage-I osteochondritis dissecans versus normal variants of ossification in the knee in children

    Full text link
    Background: Juvenile osteochondritis dissecans (OCD) has a better prognosis than the adult type. Objective : We postulated that the excellent prognosis of juvenile OCD could be explained, at least in part, by the erroneous diagnosis of some developmental variants of ossification as stage-I OCD. Materials and methods : Knee MRIs of 38 children, ages 7.5–17.7 years (mean and median age 13 years), were retrospectively reviewed to look for features that might separate normal variants of ossification from stage-I OCD. These included age, gender, site, configuration of the lesion, residual cartilaginous model and presence of edema. Results : Twenty-three patients (32 condyles) had ossification defects with intact articular cartilage suggestive of stage-I lesions. No stage-II lesions were seen in the posterior femoral condyles. Accessory ossification centers were seen in 11/16 posterior condyles and 3/16 central condyles. Spiculation of existing ossification was seen in 12/16 posterior condylar lesions and 1/16 central condyles. There was a predominance of accessory ossifications and spiculations in the patients with 10% or greater residual cartilaginous model. No edema signal greater than diaphyseal red-marrow signal was seen in the posterior condyles. Clinical follow-up ranged from 0.5 to 38 months, with clinical improvement in 22 out of 23 patients. Conclusion : Inclusion of normal variants in the stage-I OCD category might explain, in part, the marked difference in published outcome between the juvenile and adult forms of OCD. Ossification defects in the posterior femoral condyles with intact overlying articular cartilage, accessory ossification centers, spiculation, residual cartilaginous model, and lack of bone-marrow edema are features of developmental variants rather than OCD.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/46719/1/247_2005_Article_1507.pd

    Comparative study of imaging at 3.0 T versus 1.5 T of the knee

    Get PDF
    The objectives of the study were to compare MR imaging at 1.5 and 3.0 T in the same patients concerning image quality and visualization of cartilage pathology and to assess diagnostic performance using arthroscopy as a standard of reference. Twenty-six patients were identified retrospectively as having comparative 1.5 and 3.0 T MR studies of the knee within an average of 102 days. Standard protocols included T1-weighted and fat-saturated intermediate-weighted fast spin-echo sequences in three planes; sequence parameters had been adjusted to account for differences in relaxation at 3.0 T. Arthroscopy was performed in 19 patients. Four radiologists reviewed each study independently, scored image quality, and analyzed pathological findings. Sensitivities, specificities, and accuracies in diagnosing cartilage lesions were calculated in the 19 patients with arthroscopy, and differences between 1.5 and 3.0 T exams were compared using paired Student’s t tests with a significance threshold of p < 0.05. Each radiologist scored the 3.0 T studies higher than those obtained at 1.5 T in visualizing anatomical structures and abnormalities (p < 0.05). Using arthroscopy as a standard of reference, diagnosis of cartilage abnormalities was improved at 3.0 T with higher sensitivity (75.7% versus 70.6%), accuracy (88.2% versus 86.4%), and correct grading of cartilage lesions (51.3% versus 42.9%). Diagnostic confidence scores were higher at 3.0 than 1.5 T (p < 0.05) and signal-to-noise ratio at 3.0 T was approximately twofold higher than at 1.5 T. MRI at 3.0 T improved visualization of anatomical structures and improved diagnostic confidence compared to 1.5 T. This resulted in significantly better sensitivity and grading of cartilage lesions at the knee

    Comparison of the temporal release pattern of copeptin with conventional biomarkers in acute myocardial infarction

    Get PDF
    Background Early detection of acute myocardial infarction (AMI) using cardiac biomarkers of myocardial necrosis remains limited since these biomarkers do not rise within the first hours from onset of AMI. We aimed to compare the temporal release pattern of the C-terminal portion of provasopressin (copeptin) with conventional cardiac biomarkers, including creatine kinase isoenzyme (CK-MB), cardiac troponin T (cTnT), and high-sensitivity cTnT (hs-cTnT), in patients with ST-elevation AMI. Methods We included 145 patients undergoing successful primary percutaneous coronary intervention (PCI) for a first ST-elevation AMI presenting within 12 h of symptom onset. Blood samples were taken on admission and at four time points within the first 24 h after PCI. Results In contrast to all other markers, copeptin levels were already elevated on admission and were higher with a shorter time from symptom onset to reperfusion and lower systolic blood pressure. Copeptin levels peaked immediately after symptom onset at a maximum of 249 pmol/L and normalized within 10 h. In contrast, CK-MB, cTnT, and hs-cTnT peaked after 14 h from symptom onset at a maximum of 275 U/L, 5.75 lg/L, and 4.16 lg/L, respectively, and decreased more gradually. Conclusions Copeptin has a distinct release pattern in patients with ST-elevation AMI, peaking within the first hour after symptom onset before conventional cardiac biomarkers and falling to normal ranges within the first day. Further studies are required to determine the exact role of copeptin in AMI suspects presenting within the first hours after symptom onset

    The prognosis for pain, disability, activities of daily living and quality of life after an acute osteoporotic vertebral body fracture: its relation to fracture level, type of fracture and grade of fracture deformation

    Get PDF
    The level of the acute osteoporotic vertebral fracture, fracture type and grade of fracture deformation were determined in 107 consecutive patients and related to pain, disability, activities of daily living (ADL) and quality of life (QoL) after 3 weeks, 3, 6 and 12 months. Two-thirds of the fractured patients were women and with a similar average age, around 75 years, as the men. Fifty-eight of the acute fractures were located in the thoracic spine and 49 in the lumbar spine and predominantly at the Th12 and L1 levels. Sixty-nine percent of the fractures were wedge, 19% concave and 12% crush fractures. There were 22 mildly, 50 moderately and 35 severely deformed vertebrae. The grade of fracture deformation was not related to gender, age or fracture location. Severely deformed vertebrae predominantly (92%) occurred among the crush fracture type. One year after the fracture, irrespective of fracture level, fracture type or grade of fracture deformation, 4/5 still had pronounced pain and deteriorated QoL. Initial severe fracture deformation by far was the worst prognostic factor for severe lasting pain and disability, and deterioration of ADL and QoL. Factors like fracture level, lumbar fractures tended to improve steadily while thoracic deteriorated, type of fracture, the wedge and concave resulting in less pain and better QoL than the crush fracture type and gender influenced to a lesser extent the outcomes during the year after the acute fracture

    Ultrasound assessment of the lateral collateral ligamentous complex of the elbow: imaging aspects in cadavers and normal volunteers

    Get PDF
    OBJECTIVE: The Lateral Collateral Ligamentous complex (LCL) is an important stabiliser of the elbow. It has a Y-shaped structure with three components. In this study, we sought to describe the ultrasound aspect of the individual components of this ligamentous complex and to evaluate the performance of ultrasound in both cadavers and in normal subjects. METHODS: Ten cadaveric elbow specimens underwent high-frequency ultrasound. Two specimens were sliced and two were dissected for anatomical correlation. Ten elbows of normal subjects were also evaluated by ultrasound. The findings were compared. RESULTS: The three components of the LCL could be visualised in all specimens and normal subjects with the exception of the proximal portion of one specimen. In 80% of the specimens and 100% of the healthy volunteers the proximal portion of the LCL could be separated from the extensor tendons. CONCLUSION: High-resolution ultrasound can assess all components of the LCL of the elbow and can distinguish them from surrounding structures
    corecore