5 research outputs found

    Excitation energy dependence of prompt fission γ\gamma-ray emission from 241Pu∗^{241}\mathrm{Pu}{}^{*}

    No full text
    International audiencePrompt fission Îł rays (PFGs) resulting from the Pu240(d,pf) reaction have been measured as a function of fissioning nucleus excitation energy Ex at the Oslo Cyclotron Laboratory. We study the average total PFG multiplicity per fission, the average total PFG energy released per fission, and the average PFG energy. No significant changes in these characteristics are observed over the range 5.75<Ex<8.25 MeV. The physical implications of this result are discussed. The experimental results are compared to simulations conducted using the computational fission model FREYA. We find that FREYA reproduces the experimental PFG characteristics within 8% deviation across the Ex range studied. Previous excitation energy-dependent PFG measurements conducted below the second-chance fission threshold have large uncertainties, but are generally in agreement with our results within a 2σ confidence interval. However, both a published parametrization of the PFG energy dependence and the most recent PFG evaluation included in ENDF/B-VIII.0 were found to poorly describe the PFG excitation-energy dependence observed in this and previous experiments

    Measurement of the 64Zn,47Ti(n,p) cross sections using a DD neutron generator for medical isotope studies

    No full text
    Cross sections for the 47Ti(n,p)47Sc and 64Zn(n,p)64Cu reactions have been measured for quasi-monoenergetic DD neutrons produced by the UC Berkeley High Flux Neutron Generator (HFNG). The HFNG is a compact neutron generator designed as a “flux-trap” that maximizes the probability that a neutron will interact with a sample loaded into a specific, central location. The study was motivated by interest in the production of 47Sc and 64Cu as emerging medical isotopes. The cross sections were measured in ratio to the 113In(n,nâ€Č)113mIn and 115In(n,nâ€Č)115mIn inelastic scattering reactions on co-irradiated indium samples. Post-irradiation counting using an HPGe and LEPS detectors allowed for cross section determination to within 5% uncertainty. The 64Zn(n,p)64Cu cross section for 2.76-0.02+0.01 MeV neutrons is reported as 49.3 ± 2.6 mb (relative to 113In) or 46.4 ± 1.7 mb (relative to 115In), and the 47Ti(n,p)47Sc cross section is reported as 26.26 ± 0.82 mb. The measured cross sections are found to be in good agreement with existing measured values but with lower uncertainty (&lt;5%), and also in agreement with theoretical values. This work highlights the utility of compact, flux-trap DD-based neutron sources for nuclear data measurements and potentially the production of radionuclides for medical applications

    Bladder Neck Slings for Stress Urinary Incontinence

    No full text
    corecore