200 research outputs found

    Axion Cosmology Revisited

    Full text link
    The misalignment mechanism for axion production depends on the temperature-dependent axion mass. The latter has recently been determined within the interacting instanton liquid model (IILM), and provides for the first time a well-motivated axion mass for all temperatures. We reexamine the constraints placed on the axion parameter space in the light of this new mass function. We find an accurate and updated constraint f_a \le 2.8(\pm2)\times 10^{11}\units{GeV} or m_a \ge 21(\pm2) \units{\mu eV} from the misalignment mechanism in the classic axion window (thermal scenario). However, this is superseded by axion string radiation which leads to f_a \lesssim 3.2^{+4}_{-2} \times 10^{10} \units{GeV} or m_a \gtrsim 0.20 ^{+0.2}_{-0.1} \units{meV}. In this analysis, we take care to precisely compute the effective degrees of freedom and, to fill a gap in the literature, we present accurate fitting formulas. We solve the evolution equations exactly, and find that analytic results used to date generally underestimate the full numerical solution by a factor 2-3. In the inflationary scenario, axions induce isocurvature fluctuations and constrain the allowed inflationary scale HIH_I. Taking anharmonic effects into account, we show that these bounds are actually weaker than previously computed. Considering the fine-tuning issue of the misalignment angle in the whole of the anthropic window, we derive new bounds which open up the inflationary window near θa→π\theta_a \to \pi. In particular, we find that inflationary dark matter axions can have masses as high as 0.01--1\units{meV}, covering the whole thermal axion range, with values of HIH_I up to 10910^9GeV. Quantum fluctuations during inflation exclude dominant dark matter axions with masses above ma≲1m_a\lesssim 1meV.Comment: 42 pages, 12 figures, version as accepted by Phys.Rev.

    Procédé de préparation d’une couche mince à caractère photovoltaïque à hétérojonction

    Get PDF

    Temperature Dependence of Exciton Diffusion in Conjugated Polymers

    Get PDF
    The temperature dependence of the exciton dynamics in a conjugated polymer is studied using time-resolved spectroscopy. Photoluminescence decays were measured in heterostructured samples containing a sharp polymer-fullerene interface, which acts as an exciton quenching wall. Using a 1D diffusion model, the exciton diffusion length and diffusion coefficient were extracted in the temperature range of 4-293 K. The exciton dynamics reveal two temperature regimes: in the range of 4-150 K, the exciton diffusion length (coefficient) of ~3 nm (~1.5 Ă— 10-4 cm2/s) is nearly temperature independent. Increasing the temperature up to 293 K leads to a gradual growth up to 4.5 nm (~3.2 Ă— 10-4 cm2/s). This demonstrates that exciton diffusion in conjugated polymers is governed by two processes: an initial downhill migration toward lower energy states in the inhomogenously broadened density of states, followed by temperature activated hopping. The latter process is switched off below 150 K.

    Sources by Which Students Perceive Professional Counselors\u27 Effectiveness

    Get PDF
    Using qualitative research methods interviews were conducted with college students regarding the sources they used in generating perceptions of professional counselors. Respondents believed that word of mouth, media sources, and personal experiences were responsible for their understandings of professional counselors. The findings have applications for leaders in professional counseling organizations

    Cross-linkable azido C60-fullerene derivatives for efficient thermal stabilization of polymer bulk-heterojunction solar cells

    Get PDF
    International audienceOriginal [60]PCBM-inspired fullerene derivatives bearing an azidofunctional group were synthesized. By incorporating an optimizedquantity of this thermal cross-linker additive in the P3HT:[60]PCBMphotoactive layer, an impressive stabilization of the bulk-heterojunctionmorphology at its optimal photovoltaic performance wasachieved

    Mental Health Service Providers: College Student Perceptions of Helper Effectiveness

    Get PDF
    Undergraduate perceptions of the overall effectiveness of six types of mental health service providers (MHSPs) were obtained with a survey. Although many mental health services are available to consumers in the United States, research has indicated that these services are underutilized. Perceptions have been linked to therapeutic outcomes and may potentially serve as barriers to treatment. The results of the present study illustrate a range of perceptions and highlight the value of educating future consumers and practitioners about the roles of various MHSPs in providing mental health services. Future research is proposed

    Orchiectomy as a result of ischemic orchitis after laparoscopic inguinal hernia repair: case report of a rare complication

    Get PDF
    which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Background: Ischemic orchitis is an established complication after open inguinal hernia repair, but ischemic orchitis resulting in orchiectomy after the laparoscopic approach has not been reported. Case presentation: The patient was a thirty-three year-old man who presented with bilateral direct inguinal hernias, right larger than left. He was a thin, muscular male with a narrow pelvis who underwent bilateral extraperitoneal mesh laparoscopic inguinal hernia repair. The case was complicated by pneumoperitoneum which limited the visibility of the pelvic anatomy; however, the mesh was successfully deployed bilaterally. Cautery was used to resect the direct sac on the right. The patient was discharged the same day and doing well with minimal pain and swelling until the fourth day after surgery. That night he presented with sudden-onset pain and swelling of his right testicle and denied both trauma to the area and any sexual activity. Ultrasound of the testicle revealed no blood flow to the testicle which required exploration and subsequent orchiectomy. Conclusion: Ischemic orchitis typically presents 2–3 days after inguinal hernia surgery and can progress to infarction. This ischemic injury is likely due to thrombosis of the venous plexus, rathe

    Protocol for derivation of organoids and patient-derived orthotopic xenografts from glioma patient tumors

    Get PDF
    Tumor organoids and patient-derived orthotopic xenografts (PDOXs) are some of the most valuable pre-clinical tools in cancer research. In this protocol, we describe efficient derivation of organoids and PDOX models from glioma patient tumors. We provide detailed steps for organoid culture, intracranial implantation, and detection of tumors in the brain. We further present technical adjustments for standardized functional assays and drug testing.publishedVersio
    • …
    corecore