408 research outputs found

    IFMIF suitability for evaluation of fusion functional materials

    Get PDF
    The International FusionMaterials Irradiation Facility (IFMIF) is a future neutron source based on the D-Li stripping reaction, planned to test candidate fusionmaterials at relevant fusion irradiation conditions. During the design of IFMIF special attention was paid to the structural materials for the blanket and first wall, because they will be exposed to the most severe irradiation conditions in a fusion reactor. Also the irradiation of candidate materials for solid breeder blankets is planned in the IFMIF reference design. This paper focuses on the assessment of the suitability of IFMIF irradiation conditions for testing functionalmaterials to be used in liquid blankets and diagnostics systems, since they are been also considered within IFMIF objectives. The study has been based on the analysis and comparison of the main expected irradiation parameters in IFMIF and DEMO reactor

    Thermal noise of folding mirrors

    Get PDF
    Current gravitational wave detectors rely on the use of Michelson interferometers. One crucial limitation of their sensitivity is the thermal noise of their optical components. Thus, for example fluctuational deformations of the mirror surface are probed by a laser beam being reflected from the mirrors at normal incidence. Thermal noise models are well evolved for that case but mainly restricted to single reflections. In this work we present the effect of two consecutive reflections under a non-normal incidence onto mirror thermal noise. This situation is inherent to detectors using a geometrical folding scheme such as GEO\,600. We revise in detail the conventional direct noise analysis scheme to the situation of non-normal incidence allowing for a modified weighting funtion of mirror fluctuations. An application of these results to the GEO\,600 folding mirror for Brownian, thermoelastic and thermorefractive noise yields an increase of displacement noise amplitude by 20\% for most noise processes. The amplitude of thermoelastic substrate noise is increased by a factor 4 due to the modified weighting function. Thus the consideration of the correct weighting scheme can drastically alter the noise predictions and demands special care in any thermal noise design process

    Benchmarking of Uranium-238 Evaluations against Spherical Transmission and (n,xn)-Reaction Experimental Data

    Get PDF
    Abstract. The double differential cross sections for the U(n,xn) reaction at 14 MeV and neutron leakage spectra from the uranium sphere of 24 cm outer and 8 cm inner diameters with the central T-D and 252 Cf neutron sources measured at the Institute of Physics and Power Engineering were used for benchmarking the evaluated cross sections from ENDF-B6, JEFF-3.0, and "Maslov" libraries and preliminary versions of JEFF-3.1 and ENDF-B7 evaluations for 238 U
    corecore