7,581 research outputs found

    Errors on the inverse problem solution for a noisy spherical gravitational wave antenna

    Get PDF
    A single spherical antenna is capable of measuring the direction and polarization of a gravitational wave. It is possible to solve the inverse problem using only linear algebra even in the presence of noise. The simplicity of this solution enables one to explore the error on the solution using standard techniques. In this paper we derive the error on the direction and polarization measurements of a gravitational wave. We show that the solid angle error and the uncertainty on the wave amplitude are direction independent. We also discuss the possibility of determining the polarization amplitudes with isotropic sensitivity for any given gravitational wave source.Comment: 13 pages, 4 figures, LaTeX2e, IOP style, submitted to CQ

    Evidence for Antipodal Hot Spots During X-ray Bursts From 4U 1636-536

    Get PDF
    The discovery of high-frequency brightness oscillations in thermonuclear X-ray bursts from several neutron-star low-mass X-ray binaries has important implications for the beat frequency model of kilohertz quasi-periodic brightness oscillations, the propagation of nuclear burning, the structure of the subsurface magnetic fields in neutron stars, and the equation of state of high-density matter. These implications depend crucially on whether the observed frequency is the stellar spin frequency or its first overtone. Here we report an analysis of five bursts from 4U 1636-536 which exhibit strong oscillations at approximately 580 Hz. We show that combining the data from the first 0.75 seconds of each of the five bursts yields a signal at 290 Hz that is significant at the 4×10−54\times 10^{-5} level when the number of trials is taken into account. This strongly indicates that 290 Hz is the spin frequency of this neutron star and that 580 Hz is its first overtone, in agreement with other arguments about this source but in contrast to suggestions in the literature that 580 Hz is the true spin frequency. The method used here, which is an algorithm for combining time series data from the five bursts so that the phases of the 580 Hz oscillations are aligned, may be used in any source to search for weak oscillations that have frequencies related in a definite way to the frequency of a strong oscillation.Comment: 9 pages including one figure, uses aaspp4.sty, submitted to The Astrophysical Journal Letters on September 1

    Thermal diagnostic of the Optical Window on board LISA Pathfinder

    Full text link
    Vacuum conditions inside the LTP Gravitational Reference Sensor must comply with rather demanding requirements. The Optical Window (OW) is an interface which seals the vacuum enclosure and, at the same time, lets the laser beam go through for interferometric Metrology with the test masses. The OW is a plane-parallel plate clamped in a Titanium flange, and is considerably sensitive to thermal and stress fluctuations. It is critical for the required precision measurements, hence its temperature will be carefully monitored in flight. This paper reports on the results of a series of OW characterisation laboratory runs, intended to study its response to selected thermal signals, as well as their fit to numerical models, and the meaning of the latter. We find that a single pole ARMA transfer function provides a consistent approximation to the OW response to thermal excitations, and derive a relationship with the physical processes taking place in the OW. We also show how system noise reduction can be accomplished by means of that transfer function.Comment: 20 pages, 14 figures; accepted for publication in Class. Quantum Gra

    An explicit Schr\"odinger picture for Aharonov's Modular Variable concept

    Full text link
    We propose to address in a natural manner, the modular variable concept explicitly in a Schr\"odinger picture. The idea of Modular Variables was introduced in 1969 by Aharonov, Pendleton and Petersen to explain certain non-local properties of quantum mechanics. Our approach to this subject is based on Schwinger's finite quantum kinematics and it's continuous limit.Comment: 16 pages, 9 figure

    Deconvolving the information from an imperfect spherical gravitational wave antenna

    Get PDF
    We have studied the effects of imperfections in spherical gravitational wave antenna on our ability to properly interpret the data it will produce. The results of a numerical simulation are reported that quantitatively describe the systematic errors resulting from imperfections in various components of the antenna. In addition, the results of measurements on a room-temperature prototype are presented that verify it is possible to accurately deconvolve the data in practice.Comment: 5 pages, 2 figures, to be published in Europhysics Letter

    Security policy refinement using data integration: a position paper.

    No full text
    In spite of the wide adoption of policy-based approaches for security management, and many existing treatments of policy verification and analysis, relatively little attention has been paid to policy refinement: the problem of deriving lower-level, runnable policies from higher-level policies, policy goals, and specifications. In this paper we present our initial ideas on this task, using and adapting concepts from data integration. We take a view of policies as governing the performance of an action on a target by a subject, possibly with certain conditions. Transformation rules are applied to these components of a policy in a structured way, in order to translate the policy into more refined terms; the transformation rules we use are similar to those of global-as-view database schema mappings, or to extensions thereof. We illustrate our ideas with an example. Copyright 2009 ACM

    On the Sensitivity of a Hollow Sphere as a Multi-modal Resonant Gravitational Wave Detector

    Full text link
    We present a numerical analysis to simulate the response of a spherical resonant gravitational wave detector and to compute its sensitivity. Under the assump- tion of optimal filtering, we work out the sensitivity curve for a sphere first taking into account only a single transducer, and then using a coherent analysis of the whole set of transducers.Comment: 24 pages, 11 figures, published versio
    • 

    corecore