601 research outputs found

    Discovery of a Quadruple Lens in CANDELS with a Record Lens Redshift z=1.53

    Get PDF
    Using spectroscopy from the Large Binocular Telescope and imaging from the Hubble Space Telescope we discovered the first strong galaxy lens at z(lens)>1. The lens has a secure photometric redshift of z=1.53+/-0.09 and the source is spectroscopically confirmed at z=3.417. The Einstein radius (0.35"; 3.0 kpc) encloses 7.6 x 10^10 Msol, with an upper limit on the dark matter fraction of 60%. The highly magnified (40x) source galaxy has a very small stellar mass (~10^8 Msol) and shows an extremely strong [OIII]_5007A emission line (EW_0 ~ 1000A) bolstering the evidence that intense starbursts among very low-mass galaxies are common at high redshift.Comment: accepted for publication in ApJ Letter

    Raman Spectroscopy Study of alpha-, beta-, gamma-NaxCoO2 and gamma-(Ca,Sr)xCoO2

    Full text link
    Raman spectroscopy measurements have been performed on alpha-, beta-, gamma-NaxCoO2 phases differing in their stacking of CoO6 octahedra along the c-axis direction. The results demonstrate that, in general, there are five active phonons for gamma-Na0.75CoO2, two Raman active phonons for alpha-NaCoO2, and four Raman active phonons for beta-NaCoO2. We have also performed Raman scattering measurements on several gamma-(Ca,Sr)xCoO2 (0.15 <= x <= 0.35) samples which show well-defined intercalated Ca/Sr-ordering. The experimental data show that the intercalated cation ordering could result in visible alterations on Raman spectral structures. The observations of the spectral changes along with the variation of the CoO6 stacking, as well as the intercalated Sr/Ca ordering suggest that the interlayer interaction plays an important role for understanding the lattice dynamics in this layered system.Comment: 23 pages, 5 figures, Physical Review B, in pres

    The Effect of Lattice Vibrations on Substitutional Alloy Thermodynamics

    Get PDF
    A longstanding limitation of first-principles calculations of substitutional alloy phase diagrams is the difficulty to account for lattice vibrations. A survey of the theoretical and experimental literature seeking to quantify the impact of lattice vibrations on phase stability indicates that this effect can be substantial. Typical vibrational entropy differences between phases are of the order of 0.1 to 0.2 k_B/atom, which is comparable to the typical values of configurational entropy differences in binary alloys (at most 0.693 k_B/atom). This paper describes the basic formalism underlying ab initio phase diagram calculations, along with the generalization required to account for lattice vibrations. We overview the various techniques allowing the theoretical calculation and the experimental determination of phonon dispersion curves and related thermodynamic quantities, such as vibrational entropy or free energy. A clear picture of the origin of vibrational entropy differences between phases in an alloy system is presented that goes beyond the traditional bond counting and volume change arguments. Vibrational entropy change can be attributed to the changes in chemical bond stiffness associated with the changes in bond length that take place during a phase transformation. This so-called ``bond stiffness vs. bond length'' interpretation both summarizes the key phenomenon driving vibrational entropy changes and provides a practical tool to model them.Comment: Submitted to Reviews of Modern Physics 44 pages, 6 figure

    Monitoring, management, and outcome of hypotension in Intensive Care Unit patients, an international survey of the European Society of Intensive Care Medicine

    Get PDF
    INTRODUCTION: Hypotension in the ICU is common, yet management is challenging and variable. Insight in management by ICU physicians and nurses may improve patient care and guide future hypotension treatment trials and guidelines. METHODS: We conducted an international survey among ICU personnel to provide insight in monitoring, management, and perceived consequences of hypotension. RESULTS: Out of 1464 respondents, 1197 (81.7%) were included (928 physicians (77.5%) and 269 nurses (22.5%)). The majority indicated that hypotension is underdiagnosed (55.4%) and largely preventable (58.8%). Nurses are primarily in charge of monitoring changes in blood pressure, physicians are in charge of hypotension treatment. Balanced crystalloids, dobutamine, norepinephrine, and Trendelenburg position were the most frequently reported fluid, inotrope, vasopressor, and positional maneuver used to treat hypotension. Reported complications believed to be related to hypotension were AKI and myocardial injury. Most ICUs do not have a specific hypotension treatment guideline or protocol (70.6%), but the majority would like to have one in the future (58.1%). CONCLUSIONS: Both physicians and nurses report that hypotension in ICU patients is underdiagnosed, preventable, and believe that hypotension influences morbidity. Hypotension management is generally not protocolized, but the majority of respondents would like to have a specific hypotension management protocol

    Suppression of Phase Separation in LiFePO4 Nanoparticles During Battery Discharge

    Full text link
    Using a novel electrochemical phase-field model, we question the common belief that LixFePO4 nanoparticles separate into Li-rich and Li-poor phases during battery discharge. For small currents, spinodal decomposition or nucleation leads to moving phase boundaries. Above a critical current density (in the Tafel regime), the spinodal disappears, and particles fill homogeneously, which may explain the superior rate capability and long cycle life of nano-LiFePO4 cathodes.Comment: 27 pages, 8 figure

    Definition and incidence of hypotension in intensive care unit patients, an international survey of the European Society of Intensive Care Medicine

    Get PDF
    Introduction: Although hypotension in ICU patients is associated with adverse outcome, currently used definitions are unknown and no universally accepted definition exists. Methods: We conducted an international, peer-reviewed survey among ICU physicians and nurses to provide insight in currently used definitions, estimations of incidence, and duration of hypotension. Results: Out of 1394 respondents (1055 physicians (76%) and 339 nurses (24%)), 1207 (82%) completed the questionnaire. In all patient categories, hypotension definitions were predominantly based on an absolute MAP of 65 mmHg, except for the neuro(trauma) category (75 mmHg, p &lt; 0.001), without differences between answers from physicians and nurses. Hypotension incidence was estimated at 55%, and time per day spent in hypotension at 15%, both with nurses reporting higher percentages than physicians (estimated mean difference 5%, p = 0.01; and 4%, p &lt; 0.001). Conclusions: An absolute MAP threshold of 65 mmHg is most frequently used to define hypotension in ICU patients. In neuro(trauma) patients a higher threshold was reported. The majority of ICU patients are estimated to endure hypotension during their ICU admission for a considerable amount of time, with nurses reporting a higher estimated incidence and time spent in hypotension than physicians.</p

    The Dutch Consumer Quality Index: an example of stakeholder involvement in indicator development

    Get PDF
    Background: Like in several other Western countries, in the Dutch health care system regulated competition has been introduced. In order to make this work, comparable information is required about the performance of health care providers in terms of effectiveness, safety and patient experiences. Without further coordination, external actors will all try to force health care providers to be transparent. For health care providers this might result in a situation in which they have to deliver data for several sets of indicators, defined by different actors. Therefore, in the Netherlands an effort is made to define national sets of performance indicators and related measuring instruments. In this article, the following questions are addressed, using patient experiences as an example: - When and how are stakeholders involved in the development of indicators and instruments that measure the patients' experiences with health care providers? - Does this involvement lead to indicators and instruments that match stakeholders' information needs? Discussion: The Dutch experiences show that it is possible to implement national indicator sets and to reach consensus about what needs to be measured. Preliminary evaluations show that for health care providers and health insurers the benefits of standardization outweigh the possible loss of tailor-made information. However, it has also become clear that particular attention should be given to the participation of patient/consumer organisations. Summary: Stakeholder involvement is complex and time-consuming. However, it is the only way to balance the information needs of all the parties that ask for and benefit from transparency, without frustrating the health care system.

    Compact Binary Coalescences in the Band of Ground-based Gravitational-Wave Detectors

    Full text link
    As the ground-based gravitational-wave telescopes LIGO, Virgo, and GEO 600 approach the era of first detections, we review the current knowledge of the coalescence rates and the mass and spin distributions of merging neutron-star and black-hole binaries. We emphasize the bi-directional connection between gravitational-wave astronomy and conventional astrophysics. Astrophysical input will make possible informed decisions about optimal detector configurations and search techniques. Meanwhile, rate upper limits, detected merger rates, and the distribution of masses and spins measured by gravitational-wave searches will constrain astrophysical parameters through comparisons with astrophysical models. Future developments necessary to the success of gravitational-wave astronomy are discussed.Comment: Replaced with version accepted by CQG
    corecore