74 research outputs found

    Exploiting the speckle noise for compressive imaging

    Get PDF
    An optical setup is proposed for the implementation of compressive sensing with coherent images. This setup specifically exploits the natural multiplicative action of speckle noise occurring with coherent light, in order to optically realize the essential step in compressive sensing which is the multiplication with known random patterns of the image to be acquired. In the test of the implementation, we specifically examine the impact of several departures, that exist in practice, from the ideal conditions of a pure multiplicative action of the speckle. In such practical realistic conditions, we assess the feasibility, performance and robustness of the optical scheme of compressive sensing. (C) 2011 Elsevier B.V. All rights reserved

    Both a single sacral marker and the whole-body center of mass accurately estimate peak vertical ground reaction force in running.

    Get PDF
    While running, the human body absorbs repetitive shocks with every step. These shocks can be quantified by the peak vertical ground reaction force (F <sub>v,max</sub> ). To measure so, using a force plate is the gold standard method (GSM), but not always at hand. In this case, a motion capture system might be an alternative if it accurately estimates F <sub>v,max</sub> . The purpose of this study was to estimate F <sub>v,max</sub> based on motion capture data and validate the obtained estimates with force plate-based measures. One hundred and fifteen runners participated at this study and ran at 9, 11, and 13 km/h. Force data (1000 Hz) and whole-body kinematics (200 Hz) were acquired with an instrumented treadmill and an optoelectronic system, respectively. The vertical ground reaction force was reconstructed from either the whole-body center of mass (COM-M) or sacral marker (SACR-M) accelerations, calculated as the second derivative of their respective positions, and further low-pass filtered using several cutoff frequencies (2-20 Hz) and a fourth-order Butterworth filter. The most accurate estimations of F <sub>v,max</sub> were obtained using 5 and 4 Hz cutoff frequencies for the filtering of COM and sacral marker accelerations, respectively. GSM, COM-M, and SACR-M were not significantly different at 11 km/h but were at 9 and 13 km/h. The comparison between GSM and COM-M or SACR-M for each speed depicted root mean square error (RMSE) smaller or equal to 0.17BW (≤6.5 %) and no systematic bias at 11 km/h but small systematic biases at 9 and 13 km/h (≤0.09 BW). COM-M gave systematic biases three times smaller than SACR-M and two times smaller RMSE. The findings of this study support the use of either COM-M or SACR-M using data filtered at 5 and 4 Hz, respectively, to estimate F <sub>v,max</sub> during level treadmill runs at endurance speeds

    A Single Sacral-Mounted Inertial Measurement Unit to Estimate Peak Vertical Ground Reaction Force, Contact Time, and Flight Time in Running.

    Get PDF
    Peak vertical ground reaction force (Fz,max), contact time (tc), and flight time (tf) are key variables of running biomechanics. The gold standard method (GSM) to measure these variables is a force plate. However, a force plate is not always at hand and not very portable overground. In such situation, the vertical acceleration signal recorded by an inertial measurement unit (IMU) might be used to estimate Fz,max, tc, and tf. Hence, the first purpose of this study was to propose a method that used data recorded by a single sacral-mounted IMU (IMU method: IMUM) to estimate Fz,max. The second aim of this study was to estimate tc and tf using the same IMU data. The vertical acceleration threshold of an already existing IMUM was modified to detect foot-strike and toe-off events instead of effective foot-strike and toe-off events. Thus, tc and tf estimations were obtained instead of effective contact and flight time estimations. One hundred runners ran at 9, 11, and 13 km/h. IMU data (208 Hz) and force data (200 Hz) were acquired by a sacral-mounted IMU and an instrumented treadmill, respectively. The errors obtained when comparing Fz,max, tc, and tf estimated using the IMUM to Fz,max, tc, and tf measured using the GSM were comparable to the errors obtained using previously published methods. In fact, a root mean square error (RMSE) of 0.15 BW (6%) was obtained for Fz,max while a RMSE of 20 ms was reported for both tc and tf (8% and 18%, respectively). Moreover, even though small systematic biases of 0.07 BW for Fz,max and 13 ms for tc and tf were reported, the RMSEs were smaller than the smallest real differences [Fz,max: 0.28 BW (11%), tc: 32.0 ms (13%), and tf: 32.0 ms (30%)], indicating no clinically important difference between the GSM and IMUM. Therefore, these results support the use of the IMUM to estimate Fz,max, tc, and tf for level treadmill runs at low running speeds, especially because an IMU has the advantage to be low-cost and portable and therefore seems very practical for coaches and healthcare professionals

    Does Characterizing Global Running Pattern Help to Prescribe Individualized Strength Training in Recreational Runners?

    Get PDF
    This study aimed to determine if concurrent endurance and strength training that matches the global running pattern would be more effective in increasing running economy (RE) than non-matched training. The global running pattern of 37 recreational runners was determined using the Volodalen <sup>®</sup> method as being aerial (AER) or terrestrial (TER). Strength training consisted of endurance running training and either plyometric (PLY) or dynamic weight training (DWT). Runners were randomly assigned to a matched (n = 18; DWT for TER, PLY for AER) or non-matched (n = 19; DWT for AER, PLY for TER) 8 weeks concurrent training program. RE, maximal oxygen uptake V̇O <sub>2</sub> max) and peak treadmill speed at V̇O <sub>2</sub> max (PTS) were measured before and after the training intervention. None of the tested performance related variables depicted a significant group effect or interaction effect between training and grouping (p ≥ 0.436). However, a significant increase in RE, V̇O <sub>2</sub> max, and PTS (p ≤ 0.003) was found after the training intervention. No difference in number of responders between matched and non-matched groups was observed for any of the performance related variables (p ≥ 0.248). In recreational runners, prescribing PLT or DWT according to the global running pattern of individuals, in addition to endurance training, did not lead to greater improvements in RE

    Accurate estimation of peak vertical ground reaction force using the duty factor in level treadmill running.

    Get PDF
    This study aimed to 1) construct a statistical model (SMM) based on the duty factor (DF) to estimate the peak vertical ground reaction force (F <sub>v,max</sub> ) and 2) to compare the estimated F <sub>v,max</sub> to force plate gold standard (GSM). One hundred and fifteen runners ran at 9, 11, and 13km/h. Force (1000Hz) and kinematic (200Hz) data were acquired with an instrumented treadmill and an optoelectronic system, respectively, to assess force-plate and kinematic based DFs. SMM linearly relates F <sub>v,max</sub> to the inverse of DF because DF was analytically associated to the inverse of the average vertical force during ground contact time and the latter was very highly correlated to F <sub>v,max</sub> . No systematic bias and a 4% root mean square error (RMSE) were reported between GSM and SMM using force-plate based DF values when considering all running speeds together. Using kinematic based DF values, SMM reported a systematic but small bias (0.05BW) and a 5% RMSE when considering all running speeds together. These findings support the use of SMM to estimate F <sub>v,max</sub> during level treadmill runs at endurance speeds if underlying DF values are accurately measured

    Effect of the counter cation on the third order nonlinearity in anionic Au dithiolene complexes

    Get PDF
    In this work, we present the third order nonlinear optical investigation of two gold complexes, which differ by the nature of the counter cations. The impact of the different design in the architecture through a set of hydrogen bonds in the case of Au-Mel of the systems on the nonlinearity has been studied by means of the Z-scan setup under 532 nm, 30 ps laser excitation, allowing for the determination of the nonlinear absorption and refraction of the samples. Significant modification of the nonlinear optical response between the two metal complexes has been found suggesting a clear effect of the counter cation

    Optical memories, method for reading and writing such optical memories, and device for reading and writing such memories

    Get PDF
    The invention concerns a optical data memory, said memory comprising at least one layer of supporting material, said supporting material including molecules having, in a local zone, a collective state of molecules from at least one first collective state of molecules, and a second collective state of molecules. The invention is characterized in that only molecules having the first collective state of molecules in said local zone are capable of generating a second-harmonic signal when they are excited in said local zone by a reading electromagnetic radiation

    Third-order nonlinear optical response of push-pull azobenzene polymers

    Get PDF
    The nonlinear optical response of a series of azo-containing side-chain polymers is investigated using Z-scan technique, employing 35 ps and 4 ns laser pulses, at 532 nm. The systems were found to exhibit strong nonlinear optical response, dominated by nonlinear refraction. In all cases, the nonlinear absorption and refraction have been determined and are compared with those of disperse red 1 considered as reference. The corresponding third-order susceptibilities chi((3)) were determined to be as large as 10 (7) and 10 (5) esu under ps and ns laser excitation, respectively. Finally, the results are discussed and compared with other reported data

    Constructive role of sensors nonlinearities in the acquisition of partially polarized speckle images

    Get PDF
    We study the impact of the level of the speckle noise on data acquisition in a partially polarized coherent imaging system with the presence of a nonlinearity in the imaging sensor characteristic. In perfectly linear acquisition conditions, due to the essentially multiplicative action of the speckle, the image contrast is unchanged as the speckle noise level increases, and so it has no impact on the quality of the acquired images. On the contrary, in nonlinear conditions the acquisition is affected by the speckle noise level. However, this effect of the speckle is not always detrimental. We show that, in definite nonlinear conditions, there is usually an optimal level of the speckle noise that leads to a maximum quality of the acquired images. We theoretically analyze such nonlinear regimes with partially polarized speckled images. We specifically exhibit the existence of an optimal speckle noise level in the interesting case of images realized only by a depolarization contrast. Illustrations are given with a simple 1-bit hard limiter and binary images. Then, we propose and discuss as perspectives an experimental optical setup to confront theory and experiment
    corecore