2,594 research outputs found
Observation of Anomalous Internal Pair Creation in Be: A Possible Signature of a Light, Neutral Boson
Electron-positron angular correlations were measured for the isovector
magnetic dipole 17.6 MeV state (, ) ground state
(, ) and the isoscalar magnetic dipole 18.15 MeV (,
) state ground state transitions in Be. Significant
deviation from the internal pair creation was observed at large angles in the
angular correlation for the isoscalar transition with a confidence level of . This observation might indicate that, in an intermediate step, a
neutral isoscalar particle with a mass of 16.70 (stat)
(sys) MeV and was created.Comment: 5 pages, 5 figure
Coherent Pair Production by Photons in the 20-170 GeV Energy Range Incident on Crystals and Birefringence
The cross section for coherent pair production by linearly polarised photons
in the 20-170 GeV energy range was measured for photon aligned incidence on
ultra-high quality diamond and germanium crystals. The theoretical description
of coherent bremsstrahlung and coherent pair production phenomena is an area of
active theoretical debate and development. However, under our experimental
conditions, the theory predicted the combined cross section and polarisation
experimental observables very well indeed. In macroscopic terms, our experiment
measured a birefringence effect in pair production in a crystal. This study of
this effect also constituted a measurement of the energy dependent linear
polarisation of photons produced by coherent bremsstrahlung in aligned
crystals. New technologies for manipulating high energy photon beams can be
realised based on an improved understanding of QED phenomena at these energies.
In particular, this experiment demonstrates an efficient new polarimetry
technique. The pair production measurements were done using two independent
methods simultaneously. The more complex method using a magnet spectrometer
showed that the simpler method using a multiplicity detector was also viable.Comment: 10 pages, 13 figures, 1 table, REVTeX4 two column, Version for
publicatio
Radiation damage in the LHCb vertex locator
The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately 45 Ă 1012 1 MeV neutron equivalent (1 MeV neq). At the operational sensor temperature of approximately â7 °C, the average rate of sensor current increase is 18 ÎŒA per fbâ1, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of Eg = 1.16±0.03±0.04 eV obtained. The first observation of n+-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around 15 Ă 1012 of 1 MeV neq. The only n+-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately 3 Ă 1012 1 MeV neq, a decrease in the Effective Depletion Voltage (EDV) of around 25 V is observed. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n+-on-n type sensors, with rates of (1.43±0.16) Ă 10â12 V/ 1 MeV neq and (1.35±0.25) Ă 10â12 V/ 1 MeV neq measured for n+-on-p and n+-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed
Linear to Circular Polarisation Conversion using Birefringent Properties of Aligned Crystals for Multi-GeV Photons
We present the first experimental results on the use of a thick aligned Si
crystal acting as a quarter wave plate to induce a degree of circular
polarisation in a high energy linearly polarised photon beam. The linearly
polarised photon beam is produced from coherent bremsstrahlung radiation by 178
GeV unpolarised electrons incident on an aligned Si crystal, acting as a
radiator. The linear polarisation of the photon beam is characterised by
measuring the asymmetry in electron-positron pair production in a Ge crystal,
for different crystal orientations. The Ge crystal therefore acts as an
analyser. The birefringence phenomenon, which converts the linear polarisation
to circular polarisation, is observed by letting the linearly polarised photons
beam pass through a thick Si quarter wave plate crystal, and then measuring the
asymmetry in electron-positron pair production again for a selection of
relative angles between the crystallographic planes of the radiator, analyser
and quarter wave plate. The systematics of the difference between the measured
asymmetries with and without the quarter wave plate are predicted by theory to
reveal an evolution in the Stokes parameters from which the appearance of a
circularly polarised component in the photon beam can be demonstrated. The
measured magnitude of the circularly polarised component was consistent with
the theoretical predictions, and therefore is in indication of the existence of
the birefringence effect.Comment: 12 pages, 12 figures, 1 table, REVTeX4 two column, Version for
publicatio
Results on the Coherent Interaction of High Energy Electrons and Photons in Oriented Single Crystals
The CERN-NA-59 experiment examined a wide range of electromagnetic processes
for multi-GeV electrons and photons interacting with oriented single crystals.
The various types of crystals and their orientations were used for producing
photon beams and for converting and measuring their polarisation.
The radiation emitted by 178 GeV unpolarised electrons incident on a 1.5 cm
thick Si crystal oriented in the Coherent Bremsstrahlung (CB) and the
String-of-Strings (SOS) modes was used to obtain multi-GeV linearly polarised
photon beams.
A new crystal polarimetry technique was established for measuring the linear
polarisation of the photon beam. The polarimeter is based on the dependence of
the Coherent Pair Production (CPP) cross section in oriented single crystals on
the direction of the photon polarisation with respect to the crystal plane.
Both a 1 mm thick single crystal of Germanium and a 4 mm thick multi-tile set
of synthetic Diamond crystals were used as analyzers of the linear
polarisation.
A birefringence phenomenon, the conversion of the linear polarisation of the
photon beam into circular polarisation, was observed. This was achieved by
letting the linearly polarised photon beam pass through a 10 cm thick Silicon
single crystal that acted as a "quarter wave plate" (QWP) as suggested by N.
Cabibbo et al.Comment: Presented at International workshop "Relativistic Channeling and
Related Coherent Phenomena", Frascati (Rome) 23-26 March 200
Coherent bremsstrahlung, boherent pair production, birefringence and polarimetry in the 20-170 GeV energy range using aligned crystals
The processes of coherent bremsstrahlung (CB) and coherent pair production
(CPP) based on aligned crystal targets have been studied in the energy range
20-170 GeV. The experimental arrangement allowed for measurements of single
photon properties of these phenomena including their polarization dependences.
This is significant as the theoretical description of CB and CPP is an area of
active theoretical debate and development. With the theoretical approach used
in this paper both the measured cross sections and polarization observables are
predicted very well. This indicates a proper understanding of CB and CPP up to
energies of 170 GeV. Birefringence in CPP on aligned crystals is applied to
determine the polarization parameters in our measurements. New technologies for
high energy photon beam optics including phase plates and polarimeters for
linear and circular polarization are demonstrated in this experiment. Coherent
bremsstrahlung for the strings-on-strings (SOS) orientation yields a larger
enhancement for hard photons than CB for the channeling orientations of the
crystal. Our measurements and our calculations indicate low photon
polarizations for the high energy SOS photons.Comment: 23 pages, 27 figures, 2 tables, REVTeX4 two column
Performance of the LHCb Vertex Detector Alignment Algorithm determined with Beam Test Data
LHCb is the dedicated heavy flavour experiment at the Large Hadron Collider
at CERN. The partially assembled silicon vertex locator (VELO) of the LHCb
experiment has been tested in a beam test. The data from this beam test have
been used to determine the performance of the VELO alignment algorithm. The
relative alignment of the two silicon sensors in a module and the relative
alignment of the modules has been extracted. This alignment is shown to be
accurate at a level of approximately 2 micron and 0.1 mrad for translations and
rotations, respectively in the plane of the sensors. A single hit precision at
normal track incidence of about 10 micron is obtained for the sensors. The
alignment of the system is shown to be stable at better than the 10 micron
level under air to vacuum pressure changes and mechanical movements of the
assembled system.Comment: accepted for publication in NIM
Performance of the LHCb vertex locator
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 ÎŒm is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 ÎŒm for translations in the plane transverse to the beam. A primary vertex resolution of 13 ÎŒm in the transverse plane and 71 ÎŒm along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 ÎŒm is achieved for particles with transverse momentum greater than 1 GeV/c
Testing "microscopic" theories of glass-forming liquids
We assess the validity of "microscopic" approaches of glass-forming liquids
based on the sole k nowledge of the static pair density correlations. To do so
we apply them to a benchmark provided by two liquid models that share very
similar static pair density correlation functions while disp laying distinct
temperature evolutions of their relaxation times. We find that the approaches
are unsuccessful in describing the difference in the dynamical behavior of the
two models. Our study is not exhausti ve, and we have not tested the effect of
adding corrections by including for instance three-body density correlations.
Yet, our results appear strong enough to challenge the claim that the slowd own
of relaxation in glass-forming liquids, for which it is well established that
the changes of the static structure factor with temperature are small, can be
explained by "microscopic" appr oaches only requiring the static pair density
correlations as nontrivial input.Comment: 10 pages, 7 figs; Accepted to EPJE Special Issue on The Physics of
Glasses. Arxiv version contains an addendum to the appendix which does not
appear in published versio
- âŠ